background image

300S Softlight 3100K/5600K

LED Luminaire

Summary of Contents for 300S

Page 1: ...300S Softlight 3100K 5600K LED Luminaire ...

Page 2: ... this lminiare is damaged it shall be replaced by a special cord or cord exclusively available from the manufacturer or his service agent 3 The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person 4 For controllable luminaires the classification of insulation that has been maintained between LV supply and control con...

Page 3: ... WARNING Refer to National Electrical Code and local codes for cable specifications Failure to use proper cable can result in damage to equipment or danger to personnel WARNING This equipment is intended for installation in accordance with the National Electric Code and local regulations It is also intended for installation in indoor applications only Before any electrical work is performed discon...

Page 4: ...g Luminaires OPERATION AND PROGRAM LCD Display and Menu System LCD Display and Menu System Operation Menu Structure Button Functions Dimming Curve Selection Simplify 8 bit 300S 5600k LED Luminaire RDM Parameter IDs 300S 3100k LED Luminaire RDM Parameter IDs Basic 8 bit Basic 16 bit MAINTENANCE AND CARE DMX Control 300S Softl ght LED Luminaire RDM Parameter IDs i Special Cleaning Care Instruction F...

Page 5: ...MO Yoke 300S SOFTLIGHT 5600K with PO Yoke User Manual this document 1 5m PowerCon Powercord with bare end Please read all instructions before installing or using this product Retain this manual for future reference Additional product information and descriptions may be downloaded at www strandlighting com 300S Softlight LED Luminaires Installation User s Manual 300S SOFTLIGHT 3100K AC100 240V DC23...

Page 6: ...300S Softlight LED LUMINAIRE OVERVIEW High Power LED array Front of Unit Installation User s Manual 300S Softlight LED Luminaires Locking knob Power Input AC Heat Sink Safety Cable anchor point Barn door anchor point Power THRU AC Yoke DMX 512A RDM IN DMX 512A RDM THRU Value turn Push to confirm Color LCD Display Operation keypad Rear of Unit Power Input DC ...

Page 7: ...u UP Arrow Button Curves DOWN Arrow Button LCD Display DMX Address 406 Intensity 27 5600K CCT PL Curve LED 90 CRI 5000 cd LCD Display Menu System 5 Figure 2 300S Softlight LED Luminaire LCD Display Menu System 300S Softlight LED Luminaires Installation User s Manual ...

Page 8: ...g Power Units can be powered in one of two ways Direct connection to a AC power source using an AC input cable For wiring of AC input connector refer to Con necting 300S Softlight LED Luminaires to AC Power on page 7 Connection from the AC output of another 300S Softlight LED Luminaire When using this method it is very important not to connect any other type of equipment device WARNING Power THRU ...

Page 9: ...ing scheme is used Table 2 LED Luminaire IP20 Rated Models AC Input Connections 300S Softlight Figure 3 300S Softlight LED Luminaire AC Input Output Connections CAUTION In the event the AC input cable of this luminaire is damaged it must be replaced with an approved cable through an Authorized Strandlighting Dealer or Service Center Wire Color Purpose Brown Main LIVE 100 to 240VAC Blue Neutral Gre...

Page 10: ...minaire 300S Softlight Figure 4 300S Softlight LED Luminaire DMX512 Input Output Connections Note For more information on DMX512 networking and systems refer to Additional Resources for DMX512 on page 1 DMX CONTROL on page 14 For LED Luminaire DMX Mapping refer to 300S Softlight Figure 5 300S Softlight LED Luminaire DMX512 Connections Rear of Unit DMX512 RDM In DMX512 RDM THRU 300S Softlight LED L...

Page 11: ...he 300S Softlight LED Luminaire mount assembly in the M13 hole SAFETY CABLE SAFETY CABLE Is sold Is sold separately and recommended separately and recommended for all hanging installation and for all hanging installation and may be required by national may be required by national and local codes Use enclosure and local codes Use enclosure handles for safety cable anchor handles for safety cable an...

Page 12: ...d Menu Button to display the menu options and to navigate and configure the menu options as required To navigate and access menu settings selections Step 1 Make sure unit is powered and turned on Step 2 Press the desired button as shown in to access menu categories Figure 7 Step 3 Use UP DOWN arrow buttons to navigate through the various options and settings Step 4 Make changes as desired via the ...

Page 13: ... Setting Menu Setting Menu 1 Auto Lock 1 Auto Lock Off 1min 3min 10min Off 1min 3min 10min 0 255 0 255 Ext Local Ext Local Ext only Ext only Local only Local only Basic 8 bit Basic 8 bit Basic 16 bit Basic 16 bit Simple 8 bit Simple 8 bit LTP LTP Off Off Last Hold Last Hold Yes No Yes No Rev x xx Rev x xx xxxxxxxxx xxxxxxxxx 2 Intensity Format 2 Intensity Format 3 Fixture Control 3 Fixture Control...

Page 14: ...Once the choice is made push theValue Turn to confirm Step 4 LED Tungsten choice is now saved Step 4 Curves choice is now saved Step 2 Rotate the Value Turn to increase descrease the value Step 3 Once at desired Address push the Value Turn to confirm Step 4 Address is now saved Curves Button To edit and save a Curve Address Setting DMX Address 406 Intensity 27 5600K CCT PL Curve LED 90 CRI 5000 cd...

Page 15: ...ght LED Luminaire Dimmer Curves PL Curve follows the dimming curve of Philips Selecon PL series LED luminaries DMX Value Lumen Output 0 Linear Curve DMX Value Lumen Output 0 S Curve _ DMX Value Lumen Output 0 Square Curve DMX Value Lumen Output 0 PL Curve _ PL_Curve Dimming Curve Selection 13 300S Softlight LED Luminaires Installation User s Manual ...

Page 16: ...ire s menu system Table 3 300S Softlight LED Luminaire DMX Channel Mapping 8 Bit Mode Table 4 300S Softlight LED Luminaire DMX Channel Mapping Basic 8 Bit Mode Table 5 300S Softlight LED Luminaire DMX Channel Mapping Basic 16 Bit Mode DMX Channel DMX Channel DMX Channel Parameter Parameter Parameter Default Default Default Description Description Description Range Range Range Range DMX Range DMX R...

Page 17: ...e Seq MSB of Unique Seq MSB of Unique Seq LSB of Unique Seq 300S Softlight 5600K LED Luminaire RDM Parameter IDs 15 300S Softlight LED Luminaires Installation User s Manual Table 9 300S Softlight 5600K LED Luminaire RDM Manufacturer Specific PIDs for Root Device on page 18 Table 8 300S Softlight 5600K LED Luminaire RDM Parameters IDs on page 16 Table 7 300S Softlight 5600K LED Luminaire RDM UID Ta...

Page 18: ...Slot DMX_PERSONALITY DMX_PERSONALITY_DESCRIPTION SLOT_INFO DMX_START_ADDRESS SLOT_DESCRIPTION DEFAULT_SLOT_VALUE PRODUCT_DETAIL_ID_LIST DEVICE_MODEL_DESCRIPTION MANUFACTURER_LABEL DEVICE_LABEL FACTORY_DEFAULTS LANGUAGE_CAPABILITIES LANGUAGE SOFTWARE_VERSION_LABEL BOOT_SOFTWARE_VERSION_ID BOOT_SOFTWARE_VERSION_LABEL Support required for Manufacturer Specific PIDs exposed in SUPPORTED_ PARAMETERS me...

Page 19: ...x0403 0x0603 REAL_TIME_CLOCK LAMP_STATE SENSOR VALUE 0x0401 0x0201 0x1001 RESET_DEVICE 0x0601 TILT_INVERT 0x0501 DISPLAY_LEVEL LAMP_HOURS 0x0404 0x1020 PERFORM_SELFTEST 0x1030 CAPTURE_PRESET LAMP_ON_MODE RECORD_SENSORS 0x0402 0x0202 0x1010 POWER_STATE 0x0602 PAN_TILT_SWAP LAMP_STRIKES 0x0405 0x1021 SELF_TEST_DESCRIPTION 0x1031 PRESET_PLAYBACK DEVICE_POWER_CYCLES Category Sensors 0x02xx Category Di...

Page 20: ...ffdf See ANSI E1 20 2010 Standard Table A 3 0x8106 0x810A 0x8A41 0x8A00 0x8A42 0x8A0C 0x8AA1 Intensity Format Auto Lock DMX FAIL MODE Dimming Curve Dimmer Response Time Fixture Control 18 300S 5600K LED Luminaire RDM Parameter IDs 2 3 0 0 0 0 2 3 100 1 1 1 0 0 0 0 0 0 0 2 100 None None None None None None None None None None None None None None 1 1 1 1 1 1 1 U8 U8 U8 U8 U8 U8 U8 Installation User ...

Page 21: ...nique Seq MSB of Unique Seq MSB of Unique Seq LSB of Unique Seq 300S 3100K LED Luminaire RDM Parameter IDs 19 300S Softlight LED Luminaires Installation User s Manual Table 13 300S Softlight 3100K LED Luminaire RDM Manufacturer Specific PIDs for Root Device on page 22 Table 12 300S Softlight 3100K LED Luminaire RDM Parameters IDs on page 20 Table 11 300S Softlight 3100K LED Luminaire RDM UID Table...

Page 22: ... Slot DMX_PERSONALITY DMX_PERSONALITY_DESCRIPTION SLOT_INFO DMX_START_ADDRESS SLOT_DESCRIPTION DEFAULT_SLOT_VALUE PRODUCT_DETAIL_ID_LIST DEVICE_MODEL_DESCRIPTION MANUFACTURER_LABEL DEVICE_LABEL FACTORY_DEFAULTS LANGUAGE_CAPABILITIES LANGUAGE SOFTWARE_VERSION_LABEL BOOT_SOFTWARE_VERSION_ID BOOT_SOFTWARE_VERSION_LABEL Support required for Manufacturer Specific PIDs exposed in SUPPORTED_ PARAMETERS m...

Page 23: ...3 0x0603 REAL_TIME_CLOCK LAMP_STATE SENSOR VALUE 0x0401 0x0201 0x1001 RESET_DEVICE 0x0601 TILT_INVERT 0x0501 DISPLAY_LEVEL LAMP_HOURS 0x0404 0x1020 PERFORM_SELFTEST 0x1030 CAPTURE_PRESET LAMP_ON_MODE RECORD_SENSORS 0x0402 0x0202 0x1010 POWER_STATE 0x0602 PAN_TILT_SWAP LAMP_STRIKES 0x0405 0x1021 SELF_TEST_DESCRIPTION 0x1031 PRESET_PLAYBACK DEVICE_POWER_CYCLES Category Sensors 0x02xx Category Dimmer...

Page 24: ...xffdf See ANSI E1 20 2010 Standard Table A 3 0x8106 0x810A 0x8A41 0x8A00 0x8A42 0x8A0C 0x8AA1 Intensity Format Auto Lock DMX FAIL MODE Dimming Curve Dimmer Response Time Fixture Control 22 300S 3100K LED Luminaire RDM Parameter IDs 2 3 0 0 0 0 2 3 100 1 1 1 0 0 0 0 0 0 0 2 100 None None None None None None None None None None None None None None 1 1 1 1 1 1 1 U8 U8 U8 U8 U8 U8 U8 Installation User...

Page 25: ...leaning should be performed with power completely removed from the luminaire Never removeprotective covers when luminaire is powered Wear appropriate protective eye wear and gloves when cleaning the fixture All service and maintenance other than described herein should be performed by a qualified technician or Authorized Service Center 1 Special Cleaning and Care Instructions Being a solid state f...

Page 26: ... with filter clip a 20 degree honeycomb and a 36 degree honeycomb All these accessories can be equipped with the luminaire sololy or via a combination For example a 20 degree honeycomb and the barndoor and a 36 degree honeycomb plus the barndoor See illustration as below for more information Barndoor 20 degree Honeycomb 36 degree Honeycomb Note All these accessories will be sold separately ...

Page 27: ...Softlight luminaire whether individually or a combination See the illustration below for more information 300S Softlight with 36 degree honeycomb on 300S Softlight with 20 degree honeycomb on 300S Softlight with 20 degree honeycomb and the barndoor on 25 300S Softlight LED Luminaires Installation User s Manual ...

Page 28: ... sheet for more details 2 300S Softlight LED Luminaire Dimensions 50 Degrees 27 484 lumens for 5600K 5600K 300K 100V to 240V 10 auto ranging 1 5 Amps 100V 0 63 Amps 240V 50 60Hz DMX512 1990 DMX512A RDM On Board Menu 20 to 40 Degrees C 4 to 104 Degrees F 5 95 Non condensing 11 7 kg 25 74 lbs Luminaire only no accessories Aluminum Extrusion with Powder Coat IP20 CE cETL 26 TECHNICAL SPECIFICATIONS I...

Page 29: ...NOTE NOTE 27 300S Softlight LED Luminaires Installation User s Manual ...

Page 30: ...ing Asia Limited Unit C 14 F Roxy Industrial Centre No 41 49 Kwai Cheong Road Kwai Chung N T Hong Kong Tel 852 2796 9786 Fax 852 2798 6545 Strand Selecon Auckland 19 21 Kawana Street Northcote Auckland 0627 New Zealand Tel 64 9 481 0100 Fax 64 9 481 0101 Strand Lighting Europe Marssteden 152 Enschede 7547 TD The Netherlands Tel 31 53 4500424 Fax 31 53 4500425 www strandlighting com 2016 Philips Gr...

Reviews: