102 Meridian 3
ŎĵġŐŔŅġŃŶŵŵŰůġ
ťŦŧŪůŪŵŪŰůġŠġijıIJijıijijIJ
4 POWER
ON
LOGO
IJĺijıŹIJıĹıŠůŦŸį
ţŮű
Power On Logo: Power On
Æ
Show up Philips logo 3 seconds
Æ
Change to input signal.
This picture is reference only. The
official drawing will send out by PM.
5
Audio Selection
Stand-alone – On:
Isolate video and audio control input
Stand-alone – Off:
Integrate video and audio control input
Mute – On: Turn off audio
Mute – Off: Turn on audio
Horizontal scanning
Sync polarity
: Positive or Negative
Scanning frequency : 30 – 83 K Hz
Vertical scanning
Sync polarity : Positive or Negative
Scanning frequency
: 56 - 75 Hz
PS : Item 3.4 and 3.5 , as far as possible to be display (another Horizontal and Vertical)
Power input connection
Power cord length : please refer to M3 cable bundle summary file
Power cord type : 3 leads power cord with protective earth plug.
Power management
The monitor must comply with the Microsoft On Now specification, and meet EPA requirements.
Mode HSYNC VSYNC
Video
Pwr-cons.
Indication
Rec.
time
Power-On On
On
Active
48W (typ.)
< 62W(max.)
White LED
Note 3—
Note 4
Power-On
Audio and USB
On On Active
82W (typ.)
< 92W(max.)
White LED
Note 5
Standby
power Saving
Off Off
Blanked
< 0.5 W (DP
Interface<
9W)
Blinking white LED
Period 3ec on, 3sec off
(In Smile LED)
Note 1
Note 2
DC Power Off
N/A
< 0.5 W
LED Off
No USB HUB
connect.
AC Switch Off
N/A
0 W
LED Off
Note 1 : No Audio and USB HUB connect.
a. D-SUB mode,
Normal mode to Power saving mode: 19/s (Max.)
Power Saving to Normal mode: 9s, (Max.)
timing change : 7/s (Max.)