11. Repair Flow Chart
1. No Power
OK
NG
No power
Check power cable is
tightened?
Check Power “On/Off”
is “On”?
Re-plug the power cable
Replace the power board and check connections
Check the LED
indicate is OK?
Check the AC power
OK
NG
OK
NG
Turn on the Power “On/Off” switch
Replace scaler board and check connections
NG
Replace key board and check connections