13. DDC Instruction
General
DDC Data Re-programming
In case the main EEPROM with Software DDC which store all factory settings were replaced because a defect
repaired monitor’ the serial numbers have to be re-programmed.
It is advised to re- soldered the main EEPROM with Software DDC from the old board onto the new board if circuit
board have been replaced, in this case the DDC data does not need to be re-programmed.
Additional information about DDC (Display Data Channel) may be obtained from Video Electronics Standards
Association (VESA). Extended Display Identification Data (EDID) information may be also obtained from VESA.
1. An i486 (or above) personal computer or compatible.
2. Microsoft operation system Windows 95/98/2000/XP.
3. LPT drive “PORT95NT.exe” and EDID tool “VGA_PHL.exe”
4. EDID Board (715GT034-B) x1,
5. Printer cablex1, VGA cable x 1, DVI-D cable x 1
6. 12V DC power source
7. EDID data
13.1 Connect the ISP board, PC and monitor as follow:
13.2 Install the LPT drive
1. Double click the icon
to install the driver.
2. Restart the PC after the LPT driver installation
Connect to
the PC LPT
DC 12V Input
Connect to the
monitor VGA port
Summary of Contents for 221B3LPCB/00
Page 34: ...34 Meridian 3 Remark Parts position can be searched by using FIND function in PDF ...
Page 43: ...43 Meridian 3 CN751 CN002 CN004 CN752 CN755 CN756 From CN903 From CN603 USB Board ROCKER SW ...
Page 47: ...47 Meridian 3 and scaler board from the main frame 3 Disconnect all the connectors ...
Page 69: ...69 Meridian 2 15 Monitor Exploded View ...
Page 72: ...72 Meridian 3 EDID ISP TOOL 715GT034 B ...
Page 96: ...96 Meridian 3 responsibility of the supplier to provide related documentation ...