full screen 100 % duty cycle white signal
(3) Warm up: more than 30 minutes after power on with signal supplied.
(4) Ambient light: 400 – 600 lux.
(5) Ambient temperature: 20 ± 5
°
C
7.3 Test equipment
Personal computer with Windows 98/2000/XP
Luminance meter Minolta CA110
Videogenerator: Chroma 2000, 2135, 2250 or equivalent
Colour analyzer: Minolta or Chroma
10 times magnifier
Ruler / Template
Thickness gauge
Watt / Power Meter
7.4 Video Generator test sequence
Will be defined by TVI or its subcontracted quality providers.
7.5 Analog
input
Analog input R,G,B level:
0 - 850 mV max.
Polarity:
positive,
negative
Impedance:
75
Ω
± 1%
Sync:
HV separate sync, composite sync,
7.6
Optical response time
Video Bandwidth:
165 MHz (dot rate)
Typical rise time(CMO)
AUO : 5 ms
7.7 Protection circuit
The monitor will not be damaged by:
missing vertical or horizontal sync pulse
improper vertical or horizontal sync pulse (picture must be black at improper signals,
unsynchronized pictures are not allowed
)
7.8 DDC
The monitor can support DDC 2 B and DDC-CI according to the latest VESA standard.
7.8.1 DDC
Details
1 User visible strings on .inf file
Philips 200WS (20” LCD MONITOR 200WS8)
2 Manufacturer ID ( EDID data)
PHL
MSB(byte 12): 08
3 Product ID, "xxxx" 4 codes
LSB (byte 11): 50
4 maximum
resolution
1680x1050
5 Horizontal Frequency Range
30~93 KHz
6 Vertical Frequency Range
56~76Hz
7 Monitor Name (13 characteries max.)
Philips 200WS
7.9 Timings
Factory preset modes : 18
Preset modes : 45
User modes : 10
73
200WS8 LCD
Summary of Contents for 200WS8FB/00
Page 8: ......
Page 9: ......
Page 10: ......
Page 12: ...Wiring Diagram CN2 1 2 29 30 CN7 8 1 CN3 CN4 CN1 7 8 1 2 CN101 CN1 CN2 CN3 CN4 CON1 1 8 ...
Page 34: ...200WS8 LCD Layout Side View Scaler Board 34 S B 200WS8 LCD 34 ...