8.1 Acceptance test
According to MIL-STD-105D Control II level
AQL: 0.4 (major)
1.5 (minor)
(Please also refer to annual quality agreement)
Customer acceptance criteria: UAW0377/00
9. Philips’ Flat Panel Monitors Pixel Defect Policy
Philips’ Flat Panel Monitors Pixel Defect Policy
BRIGHT DOT DEFECTS
ACCEPTABLE LEVEL
MODEL
190S8
1 lit sub-pixel
3
2 adjacent lit sub-pixels
1
3 adjacent lit sub-pixels (one white pixel)
0
Distance between two bright dots
15mm
Bright dot defects within 20 mm circle
0
Total bright dot defects of all type
3
BLACK DOT DEFECTS
ACCEPTABLE LEVEL
MODEL
190S8
1 dark sub-pixel
5
2 adjacent dark sub-pixels
2
3 adjacent dark sub-pixels (one white pixel)
1
Distance between two black dots
15mm
Black dot defects within 20 mm circle*
1
Total black dot defects of all type
5
TOTAL DOT DEFECTS
ACCEPTABLE LEVEL
MODEL
190S8
Total bright or black dot defects of all type
5
Summary of Contents for 190S8FB/00
Page 4: ...4 HUDSON 8 1 Monitor Specifications ...
Page 5: ...5 HUDSON 8 ...
Page 8: ...8 HUDSON 8 Rear View ...
Page 13: ...13 HUDSON 8 4 2 Factory Preset Display Modes 4 3 Pixel Defect Policy ...
Page 14: ...14 HUDSON 8 ...
Page 15: ...15 HUDSON 8 ...
Page 29: ...29 HUDSON 8 29 HUDSON 8 ...
Page 35: ...35 HUDSON 8 3 Remove the base as Fig3 Fig4 Fig3 Fig4 ...
Page 37: ...37 HUDSON 8 5 Remove the hinge cover as Fig7 Fig8 Fig7 Fig8 ...
Page 43: ...43 HUDSON 8 Fig21 11 The end as Fig22 Fig22 ...
Page 45: ...45 HUDSON 8 ...
Page 53: ...53 HUDSON 8 b Double click start to install as follows ...
Page 54: ...54 HUDSON 8 ...
Page 55: ...55 HUDSON 8 ...
Page 60: ...60 HUDSON 8 ...
Page 61: ...61 HUDSON 8 ...
Page 62: ...62 HUDSON 8 ...
Page 64: ...64 HUDSON 8 2 Install the WinDDC_ setup Second you must install the The processing as follows ...
Page 65: ...65 HUDSON 8 ...