background image

Lightolier is a Philips group brand

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2011 Philips Group • F0711

Job Information 

Type:

Job Name: 

Cat. No.: 

Lamp(s): 

Notes:

 

Recessed Downlighting

 1104F2632ESR

Page 1 of 1  6 3/4" Aperture

 

0

®

 

1 Lt 26/32W Quad/Triple Tube Compact Fluorescent IC Remodeler

5"

4"

2 1/4"

3 7/8"

6 5/8"

7"

APERTURE

7 7/16"

 OVERALL 

HEIGHT

3 5/16"

13 3/8"

OVERALL 

LENGTH

1

2

3

4

5

Features

1. Housing:

 .032” (#20 ga.) UL listed for direct contact with thermal insulation. 

Allows installation in ceilings up to 2" thick. Can be removed for access 
to junction box, ballast and ceiling plenum. AirSeal

®

 housing minimizes air 

leakage to less than 2 CFM at 1.57 PSF (or 75pa), which complies with Model 
Energy Code (Section 602.3.3) and Washington State Energy Code (Section 
502.4) and reduces heat loss and condensation in ceiling.

2.  Junction Box:

 2" X 4" X 3 1/2" (22 cu. in.) .032" (#22 ga.) galvanized steel. UL 

listed for branch circuit wiring supplying connected luminaires. Integral cable 
clamps permit attachment of non-metallic (#12 or #14 ga.) Romex

®

 cable 

without tools or additional connectors.

3.  Socket Housing:

 Trim retaining spring secures trim to any height on housing 

wall.

4. Socket:

 (4 Pin, GX24q-3) base, molded thermo-plastic. Pre-wired with  

#18 AWG leads to junction box.

5. Ballast:

 Electronic 120V, end of life protected, FCC class “B” consumer 

limits, class “A” sound rating. Energy Star

®

 qualified.

Electrical

Input Watts: 27 

*Recommend Triple Tube Lamp for Optimal Performance

Amps: .23   

**Use Triple Tube Lamp Only.

Ballast Factor: 1.0 
Power Factor: .98
Max THD %: 10%
Min Start Temp: 0˚F/ -18˚C

Romex

®

 is a registered trademark of General Cable Industries Inc.

Options & Accessories

AirSeal

®

 Kit: LAS56R† 

(Required for AirSeal installation.)

Labels

UL (Type IC Suitable for Damp Locations)

†Complies with Air Leakage Requirements stated in the Model Energy Code, 
California Title 24  and the Washington State Energy Code when used with 
LAS56R.

Complete Fixture consists of Reflector Trim & Frame-In Kit. Select each separately.

Frame-In Kit

Reflector Trims   — See Individual Reflector Trim Specification Sheets

Voltage

Lamp

Open Downlight

Enclosed  
Diffusers

Wall  
Washer

Anodized

 

Reflector

Anodized

 

Cone

Satin Cone

Baffles

Basic White

1104F2632ESR

120V

26/32W 
Quad or 
Triple 
Tube

1143*
1144*
1144CD*

1112
1112NM
1113
1113BK
1113BKNM
1113CD
1113CDNM
1113NM
1113WH

1108
1108NM
1110
1110NM

1105
1105BNM
1105NM
1105WH
1176
1176WH

1171*
1170M1

1121
1124
1134
1177SH
1178SH**
1190** 

(26W Only)

1185**
1186
1186WH
1135**
1135WH**

Ceiling Opening 7" diameter