GENERAL PRODUCT SPECIFICATION
8639 000 10649
590
16
23
60 107P2 CM 25 GSIII
CM25-17" 107P2 92KHz AR CRT
TYPE
: 107P20/00H
BRAND : PHILIPS
00-06-07
K.C. Huang
00-06-07
7.3.1 Ionizetic radiation
Completely fulfilled International Commission of
Radio logical Protection (ICRP) requirement 0.5 mr/hrs.
Actually the set can reach 0.1 mr/hrs.
7.3.2 Safety and EMI requirements
------------------------------------
Safety - (To be decided)
EMI
- (To be decided)
EMS
-(To be decided)
LOW EMISSION
:TCO99
7.3.3 X-RAY radiation requirement /regulation
-USA/CANADA
:DHHS 21 CFR, CHAPTER 1,SUBCHAPTER J
-GERMANY
:RONTGEN VERORDNUNG ROV 1987.01.08
X-ray explosure at 5cm distance from any point of the external surface must not exceed
0.1 mR/H.
8.0 Reliabilit y
8.1 Mean time between failures
MTBF to be calculated according to Military standard
MIL-HDBK-217C.
MTBF >=75,000 Hours (Excluding CRT)
TOTAL HRS (POWER ON) X TOTAL SETS
PRACTICE of MTBF = ---------------------------------------------------------
NBR. OF FAILURED SETS
9.0 Quality assurance requirements
9.1 Acceptance test
According to MIL-STD-105D level II,
AQL
: 0.65 (Major)
2.5 (Minor)
Customer acceptance :
criteria : UAW0377/00
10.0 Serviceability
The service ability of this monitor should fulfill the
requirements which are prescribed in UAW-0346 and
must be checked with the check list UAT -0361.