background image

TM

Twin Electronic Breast Pump

ISIS             DUO

1

Please take a few minutes to read through the ENTIRE INSTRUCTION
LEAFLET before you use your ISIS i

Q

DUO for the first time. PLEASE

SAVE THESE INSTRUCTIONS. 

Unless advised otherwise by your health professional it is best to wait until your
breastfeeding routine is established before expressing – usually after around four weeks. 

Contents

PAGE

ISIS i

Q

DUO parts  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 - 3

Important safeguards  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

How to clean and sterilise your ISIS i

Q

DUO  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-6

How to assemble your ISIS i

Q

DUO  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-10

How to use your ISIS i

Q

DUO  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-13

Hints to help you succeed  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

Using your ISIS i

DUO as a manual breast pump  . . . . . . . . . . . . . . . . . . . . . . . . . .15-16

Storing your expressed breast milk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

Key to product base label and Guarantee  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

Troubleshooting guide  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19-20

If you experience any problems or need any help with this product, please call our
freephone helpline on 

0800 289 064 

(UK), 

1800 509 021 

(IRL). Our representatives

will be happy to assist you.

TM

Twin Electronic Breast Pump

ISIS             DUO

Instruction Booklet

83 0081 0425 #1   (02/05)

AVENT®, Suffolk, CO10 7QS, England

Tel. 44 1787 267 000  Fax. 44 1787 267 001

www.avent.com

For our complete catalogue of mother 

and babycare products

UK: Call FREE on

0800 289 064

UK ONLY (9am – 4.30pm Mon-Fri)

IRL: Call FREE on

1800 509 021

IRL ONLY (9am – 4.30pm Mon-Fri)

AUS:

1300 364 474

(Australia National)

AUS:

(02) 9457 0127

(Australia NSW only)

We’ve taken everything women loved about our classic ISIS manual breast pump –
the soft petal massager and fingertip sensitive control that makes it feel so gentle,
natural and comfortable – and we’ve given it an i

Q

– an electronic memory.

ISIS i

Q

learns from you. Begin by pumping

manually, then touch the button and let ISIS i

Q

quietly continue your exact pumping rhythm. 

If at any time you want to vary the rhythm,
touch the button again to revert to manual. 
ISIS i

Q

is totally responsive to your needs.

Relax and enjoy the experience because you’re
always in complete control. And when you’re
relaxed and comfortable, you express more
milk, faster.

7525-ISIS IQ IFU Cover.qxd  3/8/05  3:43 PM  Page 1

Summary of Contents for ISIS iQ DUO

Page 1: ......

Page 2: ......

Page 3: ......

Page 4: ...it is not working properly if it has been dropped or damaged or has been submerged in water Only use attachments recommended by AVENT Do not use outdoors where aerosol spray products are being used or where oxygen is being administered Only use the electric adaptor supplied with the product There are no user servicable parts inside the ISIS iQ DUO Do not attempt to open service or repair the ISIS ...

Page 5: ...st milk storage components Before you use your breast pump for the first time and every time before use you must disassemble wash and sterilise all the breast pump parts that come into contact with your breast milk See opposite You can use the dishwasher top rack only or hand wash in warm soapy water and then rinse thoroughly Do not use antibacterial cleaners or detergents as they may cause the pl...

Page 6: ...isers are specially designed to hold the ISIS breast pumps and the parts will remain sterile inside the steriliser for 3 hours provided the lid is not removed Keeping your pump sterile and compact for travel After sterilising all parts clip the funnel cover h over the funnel and let down massage cushion g and screw the travel cover s onto the pump body d in place of the milk container 6 your ISIS ...

Page 7: ...ontainer e onto the pump body until securely in place 1 How to assemble your ISIS If you are single or double pumping to assemble To ensure the pump doesn t topple insert the milk container into the stand provided f With clean hands click the white valve c into the pump body d from the bottom making sure that the pointed side of the valve faces downwards 2 4 e f b 3 d c ...

Page 8: ...a onto the pump body d so that it sits securely on top of the silicone diaphragm b 6 If not already attached push the transparent tube j securely onto the control handle a and click the control cable i into the adjacent socket 7 Carefully insert the let down massage cushion g into the pump body d making sure it completely covers the edge of the funnel This is easier if the let down massage cushion...

Page 9: ...daptor n to the pump motor m 9 Connect the wall plug lead o securely to the electric adaptor and then plug into an electrical wall socket 11 12 You can keep the other transparent tube out of the way for now by attaching it to the white clip 10 9 n o ...

Page 10: ... double pumping connector l Push the double pumping connector l onto the 2nd pump body d so that it sits firmly on top of the silicone diaphragm b For double pumping to assemble the twin pump Follow steps 1 5 as before then proceed to step 6 and 7 below 1 2 3 6 7 4 10 5 l j ...

Page 11: ...ng Switch on your ISIS iQ DUO and the light on the top of the pump motor will flash GREEN rapidly this is normal it is your iQ breast pump conducting a self test The light will then change to a continuous GREEN to indicate that the pump is ready to use If at any time this light is flashing RED stop and consult the Troubleshooting guide on pages 19 20 Press the assembled control pump firmly against...

Page 12: ...east 2 squeezes simply press the control button on the handle and the ISIS iQ DUO will automatically continue in the same way The light on the pump motor will turn from GREEN to ORANGE Your pattern will now be stored in the pump s memory even after the pump has been switched off To double pump Check that the pump is assembled exactly as described on page 10 When you re ready to double pump the sec...

Page 13: ... your finger You can then turn the pump motor off To collect your milk After you have expressed your milk unscrew the pump body from the milk container If you re using AVENT milk containers insert a sealing disc into the locking ring r and twist it onto the milk container If you re using VIA unscrew the adaptor and screw a lid onto the cup On average you will need to pump for 10 minutes to express...

Page 14: ...aby is feeding on the other or continue expressing just after a feed 6 Repositioning the pump on your breasts from time to time can help stimulate your milk ducts 7 Some women may prefer to use the pump without the let down massage cushion However it has been shown that in most cases the massaging effect of the petals flexing in and out around the areola stimulates the let down reflex and allows y...

Page 15: ...d and sterilised all the parts As before described on pages 7 8 But this time 15 Using your ISIS iQ DUO as Place the silicone diaphragm with the stem u into the pump body d making sure it fits securely around the edge to create a seal This is easier if the diaphragm is wet Position the forked end of the handle v under the diaphragm stem b and push down gently on the handle until you hear it click ...

Page 16: ...rt your back Make sure you have a glass of water nearby as expressing can be thirsty work 16 a manual breast pump Press the let down massage cushion firmly against your breast to create a perfect seal Gently squeeze the handle 5 or 6 times fairly quickly to initiate let down When you see your milk beginning to flow establish a rhythm of pumping to meet your own comfort level 1 2 ...

Page 17: ...up to 3 months If you are storing freshly expressed milk in the fridge to add to during the day only add milk which has been expressed into a sterile container Milk can only be kept like this for a maximum of 48 hours from first expression after which it must be used immediately or frozen for future use Frozen breast milk can be defrosted overnight in the refrigerator heated gradually in warm wate...

Page 18: ...be replaced free of charge during this time Please return it to the retailer where it was purchased Please keep your receipt as a proof purchase together with a note of when and where purchased For the Guarantee to be valid please note The AVENT ISIS iQ DUO Twin Electronic Breast Pump must be used according to the instructions in this booklet and connected to a suitable electricity supply The clai...

Page 19: ...may improve after practice Refer to the Hints to help you succeed section on page 14 You may be squeezing too hard You do not need to use all the suction the pump can generate Try squeezing the handle more gently and remember the 2 3 second pumping rhythm Consult your health professional breastfeeding advisor Remove and re fit the let down massage cushion to ensure it is firmly attached and pushed...

Page 20: ...parts Ensure the pump is correctly assembled and switched on with the power indicator illuminated GREEN Make sure the cables between the electrical wall socket and the pump are correctly connected Pump not responding If the pump stops working and the power light is flashing RED then a fault has been detected 3 flashes delay 3 flashes etc the pump has detected a vacuum fault Switch off the pump mot...

Page 21: ......

Reviews: