Philip Payne SPRITE 870 Series Installation Instructions Manual Download Page 4

 

Important-Safety

Before carrying out any servicing on this luminaire, ensure that the mains supply is fully isolated.

Disconnect luminaire before insulation testing of the installation.

Installation Method

Philip Payne Ltd

A SUBSIDIARY OF F.W. THORPE PLC

Thornhill Road, Solihull, B91 2HB, England.

Tel:

0121 705 2384

Fax:

0121 711 2469

e-mail:

[email protected]

Website:

http://www.philippayne.co.uk

Philip Payne Ltd registered in England No. 1361523

ISO9001

FM55077

21LFT065_2

Operation and Maintenance

Continual operation at mains voltages in excess of the rated voltage will reduce LED and expected gear life.
This luminaire uses plastic components in its construction and when installed in environments containing chemicals, degradation may occur.
Please contact our Technical Department for advice.

Modifications

Philip Payne products should not be modified.

Any modification may render the product unsafe and will invalidate any Safety/Approval marks.

Philip Payne will not accept any responsibility for any modified products or for any damage caused as a result of their modification.

Monthly and Annual Tests

Monthly and Annual tests should be carried out in accordance with BS EN 50172:2004, 7.2.

Testing can be carried out by using a sub circuit isolator or by switching off the lighting circuit at the circuit breaker (not for AutoTest or DALI versions).

Battery pack shall be replaced if the specified 3 hour duration is not met.
For replacement battery pack contact Philip Payne Ltd.

The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.

Cleaning Instructions

1

2

REAR CABLE

ENTRY

SURFACE
CABLE ENTRY
OPTION

Summary of Contents for SPRITE 870 Series

Page 1: ...s USL N DALI DALI N NM3 AutoTest DALI USL SPRT870LN 220 240V AC 50 60 Hz NM3 SPRT870YS 220 240V AC 50 60 Hz NM3 AutoTest SPRT870DS 220 240V AC 50 60 Hz DALI NM3 Maximum luminaires on a Type B 10A circuit breaker 90 luminaires 90 luminaires 90 luminaires Supply voltage Downlighter features Part No Do not stare at operating lamp It may be harmful to the eyes Basic insulation between L N and DALI DAL...

Page 2: ...Please contact our Technical Department for advice Modifications Philip Payne products should not be modified Any modification may render the product unsafe and will invalidate any Safety Approval marks Philip Payne will not accept any responsibility for any modified products or for any damage caused as a result of their modification Monthly and Annual Tests Monthly and Annual tests should be carr...

Page 3: ... 264V AC 50 60 Hz 176 264V DC Maximum luminaires on a Type B 10A circuit breaker 30 luminaires 30 luminaires Supply voltage Downlighter features Part No Do not stare at operating lamp It may be harmful to the eyes 160 160 47 15 35 9 12 35 53 71 148 45 62 80 98 115 Ø20 KNOCKOUT THIS SIDE ONLY Ø5 FIXING HOLES Ø20 CABLE ENTRY Basic insulation between L N and DALI DALI terminals ...

Page 4: ...Please contact our Technical Department for advice Modifications Philip Payne products should not be modified Any modification may render the product unsafe and will invalidate any Safety Approval marks Philip Payne will not accept any responsibility for any modified products or for any damage caused as a result of their modification Monthly and Annual Tests Monthly and Annual tests should be carr...

Page 5: ...Hz 176 280V DC DALI SPRP870LA 198 264V AC 50 60 Hz 176 264V DC SPRP870YS 220 240V AC 50 60 Hz NM3 AutoTest SPRP870DS 220 240V AC 50 60 Hz DALI NM3 Maximum luminaires on a Type B 10A circuit breaker 30 luminaires 30 luminaires 90 luminaires 90 luminaires 90 luminaires Supply voltage Downlighter features Part No Do not stare at operating lamp It may be harmful to the eyes NOTICE TO CONTRACTOR PLEASE...

Page 6: ...Installation Method 1 BASE ENTRY OPTION 4 x FIXING SCREWS NOT SUPPLED 4 x GEAR TRAY SCREWS 2 DRILL 19mm CABLE ENTRY USE GLAND SUPPLIED SIDE ENTRY OPTION ...

Page 7: ...talled in environments containing chemicals degradation may occur Please contact our Technical Department for advice Modifications Philip Payne products should not be modified Any modification may render the product unsafe and will invalidate any Safety Approval marks Philip Payne will not accept any responsibility for any modified products or for any damage caused as a result of their modificatio...

Reviews: