background image

NO.

Name

Def.

Valid

A B C

Description

8

PIR Re-

Detect 

Interval 

Time

3

1 ~
127

  

In the normal mode, after the PIR 
motion detected, setting the re-detect 
time. 8 seconds per tick, default tick is 
3 (24 seconds).
Setting the suitable value to prevent 
received the trigger signal too 
frequently. Also can save the battery 
energy.

Notice:

 If this value bigger than the 

configuration setting

 

NO. 9. There is a 

period after the light turned off and 
the PIR not start detecting.

9

Turn Off 

Light 

Time

4

0 ~
127

  

After turn on the lighting, setting the 
delay time to turn off the lighting 
when the PIR motion is not detected. 
8 seconds per tick, default tick is 4 (32
seconds).
0 means never send turn off light 
command.

10

Auto 

Report 

Battery 

Time

12

0 ~
127

  

The interval time for auto report the 
battery level. 
0 means turn off auto report battery.
The default value is 12. The tick time 
can setting by the configuration No.20.

11

Auto Report
Door/Windo
w State 
Time

12

0 ~
127

  

The interval time for auto report the 
door/window state. 
0 means turn off auto report 
door/window state.
The default value is 12. The tick time 
can setting by the configuration No.20.

NO.

Name

Def.

Valid

A B C

Description

NO.

Name

Def.

Valid

A B C

Description

12

Auto Report
Illumination
Time

12

0 ~
127

  

The interval time for auto report the 
illumination. 
0 means turn off auto report 
illumination.
The default value is 12. The tick time 
can setting by the configuration No.20.

13

Auto Report
Temperatur
e Time

12

0 ~
127

  

The interval time for auto report the 
temperature. 
0 means turn off auto report 
temperature.
The default value is 12. The tick time 
can setting by the configuration No.20.

20

Auto Report
Tick 
Interval

30

0 ~

0xFF

  

The interval time for auto report each 
tick. Setting this configuration will 
effect configuration No.10, No.11, 
No.12 and No.13.

Caution

Setting to 

0

 means turn off 

all auto report function.

21

Temperature

 

Differential 
Report

1

0 ~

0x7F

  

The temperature differential to report.
0 means turn off this function. 
The unit is Fahrenheit.
Enable this function the device will 
detect every 

minutes

And when the temperature is over 140
degree Fahrenheit, it will continue 
report.

Enable this functionality will cause 
some issue please see the detail in the
“Temperature Report” section.

NO.

Name

Def.

Valid

A B C

Description

11

Summary of Contents for PST02-A

Page 1: ...dless of vendor to increase reliability of the network The device adopt the Z WaveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed speed up communication F...

Page 2: ...groups The group 1 is for receiving the report message like triggered event temperature illumination etc The group 2 is for light control the device will send the Basic Set command to this group And each group support 8 nodes maximum Failed or success in add remove the node ID can be viewed from Z WaveTM Controller Notice 1 Always RESET a Z WaveTM device before trying to add it to a Z WaveTM netwo...

Page 3: ...changed the device will unsolicited to send the Sensor Multilevel Report to the nodes in the group 1 Sensor Type Temperature 0x01 Note To disable this functionality by setting the configuration N0 5 bit5 to 1 Temperature differential report This function default is enabled to disable this function by setting the configuration NO 21 to 0 In the default when the temperature is changed to plus or min...

Page 4: ...o zero to disable the auto report And the configuration NO 20 could change the tick interval the default value is 30 if setting to 1 that means the minimum auto report interval will be one minute And please notice if setting this value to zero that means disable all of the timing report except the low battery detection Power Up Procedure Battery Power Check When the device power up the device will...

Page 5: ... set the operation mode Operation Mode There are two modes Test and Normal Test Mode is for the user test the sensor function when installation Normal Mode for the normal operation When the event triggered normally the LED won t indicated unless the battery is in the low level the LED will flash once But in the Test Mode the LED also will light ON one second When the event triggered the device wil...

Page 6: ...6 ...

Page 7: ...release the cover 2 Hold the front cover and pull back 3 Hold the front cover and pull up Replace the new battery and install the cover back 1 Put the front cover bottom to 1 1 and press down 2 Push the front cover top to 2 1 Choosing a Suitable Location 1 The recommended mounting height is 160cm 2 Don t let the device facing the window or the sunlight 3 Don t let the device facing the source of h...

Page 8: ...inafter referred to as A tape and another is thinner hereinafter referred to as B tape you can use A tape for the test at the beginning The right way for A tape installation is stick it to the position below tamper key The thicker tape won t let the tamper key pressed so the sensor will enter the test mode You may test if installed position is good or not by this way After finish the test and deci...

Page 9: ...he light 1 means darkest 99 means brightest 100 means turn off illumination detected function And always turn on the light Notice In none test mode only the value in 1 to 99 will enable the illumination detected function and update the illumination value NO Name Def Valid A B C Description NO Name Def Valid A B C Description 5 Operation Mode 0 All Operation mode Using bit to control 0 Bit0 Reserve...

Page 10: ... light when door window closed 1 Disable 0 Enable 0 Bit5 Disable auto turn off the light after door window opened to turn on the light 1 Disable 0 Enable Notice If bit2 is zero this setting is useless Notice If the configuration No 9 is zero this setting is useless 0 Bit6 Reserve 0 Bit7 Reserve NO Name Def Valid A B C Description NO Name Def Valid A B C Description 7 Customer Function 4 All Custom...

Page 11: ... window state The default value is 12 The tick time can setting by the configuration No 20 NO Name Def Valid A B C Description NO Name Def Valid A B C Description 12 Auto Report Illumination Time 12 0 127 The interval time for auto report the illumination 0 means turn off auto report illumination The default value is 12 The tick time can setting by the configuration No 20 13 Auto Report Temperatur...

Page 12: ...RER_SPECIFIC_V2 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_SENSOR_BINARY_V2 COMMAND_CLASS_SENSOR_MULTILEVEL_V5 COMMAND_CLASS_WAKE_UP_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_MULTI_CMD COMMAND_CLASS_SECURITY COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 COMMAND_CLASS_MARK COMMAND_CLASS_BASIC Specifications Power by CR123A lithium battery Sign...

Page 13: ...to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modif...

Reviews: