NO.
Name
Def.
Valid
A B C
Description
8
PIR Re-
Detect
Interval
Time
3
1 ~
127
In the normal mode, after the PIR
motion detected, setting the re-detect
time. 8 seconds per tick, default tick is
3 (24 seconds).
Setting the suitable value to prevent
received the trigger signal too
frequently. Also can save the battery
energy.
Notice:
If this value bigger than the
configuration setting
NO. 9. There is a
period after the light turned off and
the PIR not start detecting.
9
Turn Off
Light
Time
4
0 ~
127
After turn on the lighting, setting the
delay time to turn off the lighting
when the PIR motion is not detected.
8 seconds per tick, default tick is 4 (32
seconds).
0 means never send turn off light
command.
10
Auto
Report
Battery
Time
12
0 ~
127
The interval time for auto report the
battery level.
0 means turn off auto report battery.
The default value is 12. The tick time
can setting by the configuration No.20.
11
Auto Report
Door/Windo
w State
Time
12
0 ~
127
The interval time for auto report the
door/window state.
0 means turn off auto report
door/window state.
The default value is 12. The tick time
can setting by the configuration No.20.
NO.
Name
Def.
Valid
A B C
Description
NO.
Name
Def.
Valid
A B C
Description
12
Auto Report
Illumination
Time
12
0 ~
127
The interval time for auto report the
illumination.
0 means turn off auto report
illumination.
The default value is 12. The tick time
can setting by the configuration No.20.
13
Auto Report
Temperatur
e Time
12
0 ~
127
The interval time for auto report the
temperature.
0 means turn off auto report
temperature.
The default value is 12. The tick time
can setting by the configuration No.20.
20
Auto Report
Tick
Interval
30
0 ~
0xFF
The interval time for auto report each
tick. Setting this configuration will
effect configuration No.10, No.11,
No.12 and No.13.
Caution
:
Setting to
0
means turn off
all auto report function.
21
Temperature
Differential
Report
1
0 ~
0x7F
The temperature differential to report.
0 means turn off this function.
The unit is Fahrenheit.
Enable this function the device will
detect every
minutes
.
And when the temperature is over 140
degree Fahrenheit, it will continue
report.
Enable this functionality will cause
some issue please see the detail in the
“Temperature Report” section.
NO.
Name
Def.
Valid
A B C
Description
11
Summary of Contents for PST02-A