background image

COMMAND_CLASS_BATTERY

COMMAND_CLASS_NOTIFICATION_V4

COMMAND_CLASS_ASSOCIATION_V2

COMMAND_CLASS_CONFIGURATION

COMMAND_CLASS_SENSOR_BINARY_V2

COMMAND_CLASS_WAKE_UP_V2

Operation Mode

There are two modes “Test” and “Normal”. “Test Mode” is for the user

test   the   sensor   function   when   installation.“Normal   Mode”   is   for   the

normal operation.

Operation Mode can be switched by pressing button or tamper key two

times.   LED   can   indicate   which   mode   it   is.   Lighting   on   one   second

means entering test mode, flashing once means entering normal mode.

When the event triggered, normally the LED won't indicated, unless the

battery is in the low level, the LED will flash once. But in the “Test

Mode” the LED also will light ON one second.

When the event triggered, the device will report the messages to the

nodes in the group 1. The messages also include the battery level. The

user   can   switch   the   report   by   setting   the   configuration   NO.   7   bit6

(battery). 

When the event triggered, the device will emit the signal to turn ON the

lighting equipment, those nodes are in the group 2. And delay a while

to turn OFF the lighting equipment. The delay time is setting by the

configuration NO. 9. 

The  PIR  motion  re-detected  interval,   in   the  “Test   Mode”   fixed  to  6

seconds.   In   the   “Normal   Mode”,   it   according   to   the   setting   of   the

configuration NO. 8.

Choosing a Suitable Location

1. The recommended mounting height is 160cm

2. Don't let the device facing the window or the sunlight.

3. Don't let the device facing the source of heat. For instance the

heater or the air-condition.

Battery Installation

When the device reports the low battery message, users should

replace the battery. The battery type is CR123A, 3.0V.

4

Summary of Contents for PSP05

Page 1: ...act as repeaters regardless of vendor to increase reliability of the network The device adopt the Z WaveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed sp...

Page 2: ...is group And each group support 8 nodes maximum Failed or success in add remove the node ID can be viewed from Z WaveTM Controller Notice 1 Always RESET a Z WaveTM device before trying to add it to a Z WaveTM network Notice 2 When the device into NWI mode the sensor functionality will useless The NWI mode will timeout after 30 seconds You can press the button one time to abort the NWI mode Z WaveT...

Page 3: ... the timing report except the low battery detection Power Up Procedure Battery Power Check When the device power up the device will detect the power level of the battery immediately If the power level is too low the LED will continue flash about 5 seconds Please change another new battery PIR Warm Up When the device power on the PIR need to warm up before the operation The warm up time about 1 min...

Page 4: ...gered the device will report the messages to the nodes in the group 1 The messages also include the battery level The user can switch the report by setting the configuration NO 7 bit6 battery When the event triggered the device will emit the signal to turn ON the lighting equipment those nodes are in the group 2 And delay a while to turn OFF the lighting equipment The delay time is setting by the ...

Page 5: ...t is allowed any value but no effect Z Wave Supported Command Class COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_BATTERY COMMAND_CLASS_NOTIFICATION_V4 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_SENSOR_BINARY_V2 COMMAND_CLASS_WAKE_UP_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_POWERLEVEL COMMAND_CLA...

Page 6: ...oom 0 In the same room Default 1 In the different room Notice If this bit is 1 it is recommended also set the Bit1 to 1 cause the PIR triggered doesn t mean the people in that room NO Name Def Valid Description 0 Bit4 Disable delay 5 seconds to turn off the light when door window closed 1 Disable 0 Enable 0 Bit5 Disable auto turn off the light after door window opened to turn on the light 1 Disabl...

Page 7: ...means never send turn off light command 10 Auto Report Battery Time 12 0 127 The interval time for auto report the battery level 0 means turn off auto report battery The default value is 12 The tick time can setting by the configuration No 20 20 Auto Report Tick Interval 30 128 127 The interval time for auto report each tick Setting this configuration will effect configuration No 10 NO Name Def Va...

Page 8: ...ion which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced r...

Reviews: