background image

Notice

: Including a node ID allocated by Z-Wave

TM

 Controller means 

Add

” or “

Inclusion

”.  Excluding a node ID allocated by Z-Wave

TM

  

Controller means “

Remove

” or “

Exclusion

”.

Function

Description

Add

1. Have Z-Wave

TM

 Controller entered inclusion mode.

2. Pressing button or tamper key thrice to enter the 

inclusion mode.

3. After add successful, the device will wake to 

receive the setting command from Z-Wave

TM

 

Controller about 20 seconds.

Remove

1. Have Z-Wave

TM

 Controller entered exclusion mode.

2. Pressing button or tamper key thrice to enter the 

exclusion mode. Node ID has been excluded.

Reset

Notice: Use this procedure only in the event 

that the primary controller is lost or 

otherwise inoperable.

1. Pressing button four times and keep about 5 

seconds.

2. IDs are excluded and all settings will reset to 

factory default.

Association

1. Have Z-Wave

TM

 Controller entered association 

mode.

2. Pressing button one time to enter the association 

mode.

Note: The device support 2 groups. The group 1 is for 

receiving the report message, like triggered event, 

temperature, illumination etc. The group 2 is for light 

control, the device will send the “Basic Set” command 

to this group. And each group support 8 nodes 

maximum.

Failed or success in add/remove the node ID can be viewed 

from Z-Wave

TM

 Controller.

Notice 1:

 Always RESET a Z-Wave

TM

 device before trying to add it to a 

Z-Wave

TM

 network 

Notice 2:

 When the device into NWI mode, the sensor functionality 

will useless. The NWI mode will timeout after 30 seconds. You can 

press the button one time to abort the NWI mode.

Z-Wave

TM

 Notification

After the device adding to the network, it will wake-up once per day in

default. When it wake-up it will broadcast the “Wake Up Notification”

message   to   the   network,   and   wake-up   10   seconds   for   receive   the

setting commands.

The wake-up interval minimum setting is 30 minutes, and maximum

setting is 120 hours. And the interval step is 30 minutes.

If the user want to wake-up the device immediately, please remove the

front cover, and press the button once. The device will wake-up 10

seconds.

Z-Wave

TM

 Message Report

When the PIR motion triggered, the device will report the trigger event

and also report the battery status.

In default  the  device will using Notification Report to represent the

trigger event, it can be changed to Sensor Binary Report by setting the

configuration NO. 7 Bit4 to 1.

* Motion Report:

When the PIR motion detected, the device will unsolicited to send the

report to the nodes in the group 1.

Notification Report (V4)

2

Summary of Contents for PSP05

Page 1: ...act as repeaters regardless of vendor to increase reliability of the network The device adopt the Z WaveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed sp...

Page 2: ...is group And each group support 8 nodes maximum Failed or success in add remove the node ID can be viewed from Z WaveTM Controller Notice 1 Always RESET a Z WaveTM device before trying to add it to a Z WaveTM network Notice 2 When the device into NWI mode the sensor functionality will useless The NWI mode will timeout after 30 seconds You can press the button one time to abort the NWI mode Z WaveT...

Page 3: ... the timing report except the low battery detection Power Up Procedure Battery Power Check When the device power up the device will detect the power level of the battery immediately If the power level is too low the LED will continue flash about 5 seconds Please change another new battery PIR Warm Up When the device power on the PIR need to warm up before the operation The warm up time about 1 min...

Page 4: ...gered the device will report the messages to the nodes in the group 1 The messages also include the battery level The user can switch the report by setting the configuration NO 7 bit6 battery When the event triggered the device will emit the signal to turn ON the lighting equipment those nodes are in the group 2 And delay a while to turn OFF the lighting equipment The delay time is setting by the ...

Page 5: ...t is allowed any value but no effect Z Wave Supported Command Class COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_BATTERY COMMAND_CLASS_NOTIFICATION_V4 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_SENSOR_BINARY_V2 COMMAND_CLASS_WAKE_UP_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_POWERLEVEL COMMAND_CLA...

Page 6: ...oom 0 In the same room Default 1 In the different room Notice If this bit is 1 it is recommended also set the Bit1 to 1 cause the PIR triggered doesn t mean the people in that room NO Name Def Valid Description 0 Bit4 Disable delay 5 seconds to turn off the light when door window closed 1 Disable 0 Enable 0 Bit5 Disable auto turn off the light after door window opened to turn on the light 1 Disabl...

Page 7: ...means never send turn off light command 10 Auto Report Battery Time 12 0 127 The interval time for auto report the battery level 0 means turn off auto report battery The default value is 12 The tick time can setting by the configuration No 20 20 Auto Report Tick Interval 30 128 127 The interval time for auto report each tick Setting this configuration will effect configuration No 10 NO Name Def Va...

Page 8: ...ion which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced r...