Notice
: Including a node ID allocated by Z-Wave
TM
Controller means
“
Add
” or “
Inclusion
”. Excluding a node ID allocated by Z-Wave
TM
Controller means “
Remove
” or “
Exclusion
”.
Function
Description
Add
1. Have Z-Wave
TM
Controller entered inclusion mode.
2. Pressing button or tamper key thrice to enter the
inclusion mode.
3. After add successful, the device will wake to
receive the setting command from Z-Wave
TM
Controller about 20 seconds.
Remove
1. Have Z-Wave
TM
Controller entered exclusion mode.
2. Pressing button or tamper key thrice to enter the
exclusion mode. Node ID has been excluded.
Reset
Notice: Use this procedure only in the event
that the primary controller is lost or
otherwise inoperable.
1. Pressing button four times and keep about 5
seconds.
2. IDs are excluded and all settings will reset to
factory default.
Association
1. Have Z-Wave
TM
Controller entered association
mode.
2. Pressing button one time to enter the association
mode.
Note: The device support 2 groups. The group 1 is for
receiving the report message, like triggered event,
temperature, illumination etc. The group 2 is for light
control, the device will send the “Basic Set” command
to this group. And each group support 8 nodes
maximum.
•
Failed or success in add/remove the node ID can be viewed
from Z-Wave
TM
Controller.
Notice 1:
Always RESET a Z-Wave
TM
device before trying to add it to a
Z-Wave
TM
network
Notice 2:
When the device into NWI mode, the sensor functionality
will useless. The NWI mode will timeout after 30 seconds. You can
press the button one time to abort the NWI mode.
Z-Wave
TM
Notification
After the device adding to the network, it will wake-up once per day in
default. When it wake-up it will broadcast the “Wake Up Notification”
message to the network, and wake-up 10 seconds for receive the
setting commands.
The wake-up interval minimum setting is 30 minutes, and maximum
setting is 120 hours. And the interval step is 30 minutes.
If the user want to wake-up the device immediately, please remove the
front cover, and press the button once. The device will wake-up 10
seconds.
Z-Wave
TM
Message Report
When the PIR motion triggered, the device will report the trigger event
and also report the battery status.
In default the device will using Notification Report to represent the
trigger event, it can be changed to Sensor Binary Report by setting the
configuration NO. 7 Bit4 to 1.
* Motion Report:
When the PIR motion detected, the device will unsolicited to send the
report to the nodes in the group 1.
Notification Report (V4)
2