  2.Correct the position of the lock tongue

2.1 The infrared detection hole must be aligned with the bolt and a
reflective tape between the two.

2.2 Press and hold the button for 3 seconds, then let go, the LED light
will be on for 20 seconds. Before the light is off, close the door. After
the door is closed, lock the lock tongue in 5 seconds. When 5 seconds
is reached,

The infrared will be emitted and the received signal will be stored as a
standard on the lock. When the calibration is completed, the status will
be reported from

 Z-Wave.

Disposal

This marking indicates that this product should not be 
disposed with other household wastes throughout the EU. To 
prevent possible harm to the environment or human health 
from uncontrolled waste disposal, recycle it responsibly to 
promote the sustainable reuse of material resources. To 
return your used device, please use the return and collection 
systems or contact the retailer where the product was 
purchased. They can take this product for environmental safe 
recycling.

Company:  Philio Technology Corporation
Address: 8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City 
24257, Taiwan (R.O.C)

www.philio-tech.com

FCC Interference Statement

This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. 
These limits are designed to provide reasonable protection against harmful in-
terference in a residential installation. 
This equipment generates, uses and can radiate radio frequency energy and, if 
not installed and used in accordance with the instructions, may cause harmful 
interference to radio communications. 
However, there is no guarantee that interference will not occur in a particular 
installation. 
If this equipment does cause harmful interference to radio or television recep-
tion, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.

6

Summary of Contents for PSM09-A

Page 1: ...that can defeat a safeguard for example in the case of some lithium battery types disposal of a battery into fire or a hot oven or mechanically crushing or cutting of a battery that can result in an explosion leaving a battery in an extremely high temperature surrounding environment that can result in an explosion or the leakage of flammable liquid or gas a battery subjected to extremely low air p...

Page 2: ... ID allocated by Z WaveTM Controller means Remove or Exclusion Function Description Add 1 Have Z WaveTM Controller entered inclusion mode Pressing tamper key three times within 3 seconds to enter the inclusion mode If the learning code is successful the LED will flash slowly Remove 1 Have Z WaveTM Controller entered exclusion mode Pressing tamper key three times within 3 seconds to enter the exclu...

Page 3: ... for receive the setting commands The wake up interval minimum setting is 30 minutes and maximum setting is 120 hours And the interval step is 30 minutes If the user want to wake up the device immediately please press the tamper key once The device will wake up 10 seconds Z WaveTM Auto Report After the device adding to the network it will auto report every 6 hours in default When it auto report it...

Page 4: ... is allowed any value but no effect Security Network The device supports the security function When the device included with a security controller the device will auto switch to the security mode In the security mode the follow commands need using Security CC wrapped to communicate otherwise it will not response COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_SUPERVISION COMMAND_CLASS_WAKE_UP COMMAND_C...

Page 5: ...uitable Location 1 1 The recommended mounting position is above the bolt and the distance from the lock tongue is less than 4 cm 1 2 Infrared detection hole must be aligned downward with the lock tongue 1 3 As close as possible to the lock tongue the better 5 ...

Page 6: ...ompany Philio Technology Corporation Address 8F No 653 2 Zhongzheng Rd Xinzhuang Dist New Taipei City 24257 Taiwan R O C www philio tech com FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful in terference in a resid...

Page 7: ...r transmitter Warning Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When rep...

Reviews: