Symptom

Cause of Failure

Recommendation

The device can not 
join to Z-Wave™ 
network

The device may in a Z-
Wave™ network.

Exclude the device 
then include again.

For Instruction to http:// www.philio-tech.com

Add to/Remove from Z-Wave

TM

 Network

There are one tamper key in the device,the key is in the front side. Both of
them can add, remove, reset or association from Z-Wave

TM

 network.

SmartStart enabled products can be added into a Z-Wave network by scanning 
the Zwave QR Code present on the product providing SmartStart inclusion. No 
further action is required and the SmartStart product will be added 
automatically within 10 minutes of minutes On in the network vicinity

Notice

: Including a node ID allocated by Z-Wave

TM

 Controller means “

Add

” or 

Inclusion

”.  Excluding a node ID allocated by Z-Wave

TM

  Controller means 

Remove

” or “

Exclusion

”.

Function

Description

Add

1.

Have Z-Wave

TM

 Controller entered inclusion mode.

Pressing tamper key three times within 3 seconds to 
enter the inclusion mode.
If the learning code is successful, the LED will flash 
slowly.

Remove

1.

Have Z-Wave

TM

 Controller entered exclusion mode.

Pressing tamper key three times within 3 seconds to 
enter the exclusion mode.
If the removal is successful, the code light will flash for 
30 seconds.
Node ID has been excluded.

Reset

Notice: Use this procedure only in the event that the 
primary controller is lost or otherwise inoperable.

1.

In 3 seconds, press the button 3 times continuously, 
after 3 successful, then slowly flash for 1 second, press 
the fourth button, do not release the button, the LED 
will light up, after about three seconds, the LED will off, 
and in two seconds Release the button internally. If the 
clearing is successful, the LED will flash slowly. If it fails,
the LED will flash quickly.

2

Summary of Contents for PSM09-A

Page 1: ...that can defeat a safeguard for example in the case of some lithium battery types disposal of a battery into fire or a hot oven or mechanically crushing or cutting of a battery that can result in an explosion leaving a battery in an extremely high temperature surrounding environment that can result in an explosion or the leakage of flammable liquid or gas a battery subjected to extremely low air p...

Page 2: ... ID allocated by Z WaveTM Controller means Remove or Exclusion Function Description Add 1 Have Z WaveTM Controller entered inclusion mode Pressing tamper key three times within 3 seconds to enter the inclusion mode If the learning code is successful the LED will flash slowly Remove 1 Have Z WaveTM Controller entered exclusion mode Pressing tamper key three times within 3 seconds to enter the exclu...

Page 3: ... for receive the setting commands The wake up interval minimum setting is 30 minutes and maximum setting is 120 hours And the interval step is 30 minutes If the user want to wake up the device immediately please press the tamper key once The device will wake up 10 seconds Z WaveTM Auto Report After the device adding to the network it will auto report every 6 hours in default When it auto report it...

Page 4: ... is allowed any value but no effect Security Network The device supports the security function When the device included with a security controller the device will auto switch to the security mode In the security mode the follow commands need using Security CC wrapped to communicate otherwise it will not response COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_SUPERVISION COMMAND_CLASS_WAKE_UP COMMAND_C...

Page 5: ...uitable Location 1 1 The recommended mounting position is above the bolt and the distance from the lock tongue is less than 4 cm 1 2 Infrared detection hole must be aligned downward with the lock tongue 1 3 As close as possible to the lock tongue the better 5 ...

Page 6: ...ompany Philio Technology Corporation Address 8F No 653 2 Zhongzheng Rd Xinzhuang Dist New Taipei City 24257 Taiwan R O C www philio tech com FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful in terference in a resid...

Page 7: ...r transmitter Warning Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When rep...

Reviews: