background image

nodes in the group 1. 

The device will measure the temperature in every 64 seconds. And if

the temperature is over 140 degree Fahrenheit (60 degree Celsius), the

device also report in each measurement. 

* Illumination Report:

When the PIR motion detected or the door/window state changed, the

device will unsolicited to send the  “Sensor Multilevel Report” to the

nodes in the group 1.

Sensor Type: Luminance (0x03)

Note: To disable this functionality by setting the configuration setting

N0.5, the bit4 of the value to 1.

* Timing Report:

Beside   the   event   triggered  could  report  message,   the   device   also

support the timing unsolicited report of the status.

Battery level report: Every 6 hours report once in default.

It could be changed by configuration setting NO. 10.

Low battery report: When the battery level is too low, every 30

minutes will report once.

Door/window state report: Every 6 hours report once in default.

It could be changed by configuration setting NO. 11.

Illumination level report: Every 6 hours report once in default.

It could be changed by configuration setting NO. 12.

Temperature report: Every 6 hours report once in default.

It could be changed by configuration setting NO. 13.

Power Up Procedure

* Battery Power Check

When   the   power   up,   the   device   will   detect   the   power   level   of   the

battery immediately. If the power level is too low, the LED will continue

flash about 5 seconds. Please change another new battery.

* PIR Warm Up

When the power on, the PIR need to warm up before operation. The

warm up time about 1 minute, the LED will flash in every 2 seconds.

After finish the procedure the LED will light ON three times.

* NWI

When the power on, the device will check is it already adding to the

network? If doesn't, it will auto start the NWI mode. The LED will flash

in every second and continue 30 seconds. Until timeout or the device

successful to inclusion by controller.

* Wake

When the power on, the device will wake about 20 seconds. In this

duration, the controller can communicate with the device. Normally the

device is always sleeping to save the battery energy.

Function DIP Switch

There is one function DIP switch in front of the device.

Remove the front cover in the right top of the PCB, and also has mark

“M1” and “M2” for two switch.

M1 M2

Description

ON ON Test Mode.
ON OFF Security Mode.

OFF ON Home Automation Mode.

OFF OFF Program Mode. According to the configuration setting 

NO. 5 to set the operation mode.

Operation Mode

There are three operation modes of the device. The user can choosing

the suitable mode for application.

3

Summary of Contents for PSM02

Page 1: ...s in the front side They have the same function Both of them can inclusion exclusion reset or association from Z WaveTM network In the first time add the device into the Z WaveTM network First make sure the primary controller is in the inclusion mode And then power on the device just take out the insulation Mylar in the back side of the device The device will auto start the NWI Network Wide Inclus...

Page 2: ...he device immediately please remove the front cover and press the tamper key once The device will wake up 10 seconds Z WaveTM Message Report Motion Report When the PIR motion detected the device will unsolicited to send the Sensor Binary Report to the nodes in the group 1 Sensor Type Motion 0x0C Sensor Value 0xFF Door Window Report When the Door Window state changed the device will unsolicited to ...

Page 3: ...setting NO 13 Power Up Procedure Battery Power Check When the power up the device will detect the power level of the battery immediately If the power level is too low the LED will continue flash about 5 seconds Please change another new battery PIR Warm Up When the power on the PIR need to warm up before operation The warm up time about 1 minute the LED will flash in every 2 seconds After finish t...

Page 4: ...by configuration setting NO 5 Caution In the Home Automation Mode if the environment luminance higher than the setting the device won t report the message When the event triggered if the environment luminance is less than the setting of the configuration setting NO 4 the device will emit the signal to turn ON the lighting equipment those nodes in the group 2 And delay a while to turn OFF the light...

Page 5: ...5 ...

Page 6: ...ar a click sound 2 Hold the front cover and pull back 3 Hold the front cover and pull up Replace the new battery and install the cover back 1 Put the front cover bottom to 1 1 and press down 2 Push the front cover top to 2 1 Choosing a Suitable Location 1 The recommended mounting height is 160cm 2 Don t let the device facing the window or the sunlight 3 Don t let the device facing the source of he...

Page 7: ...eferred to as A tape and another is thinner hereinafter referred to as B tape you can use A tape for the test at the beginning The right way for A tape installation is stick it to the position below tamper key The thicker tape won t let the tamper key close so the sensor will enter the test mode You may test if installed position is good or not by this way After finish the test and decide to fix t...

Page 8: ...en the DIP Switch setting to program mode If bit1 is enabled the bit0 is useless Bit2 Disable the door window function Bit3 Setting the temperature scale 0 Fahrenheit 1 Celsius Bit4 Disable illumination report after event triggered Bit5 Disable temperature report after event triggered 6 Multi Sensor Function Switch 4 0 127 Multi Sensor function switch Using bit to control Bit0 Disable magnetic int...

Page 9: ...e 30 minutes per tick and minimum time is 30 minutes default tick is 12 6 hours 12 Auto Report Illumination Time 12 1 127 The interval time for auto report the illumination 30 minutes per tick and minimum time is 30 minutes default tick is 12 6 hours 13 Auto Report Temperature Time 12 1 127 The interval time for auto report the temperature 30 minutes per tick and minimum time is 30 minutes default...

Page 10: ...is equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that...

Reviews: