Philio PHI PST02-1C Quick Start Manual Download Page 3

06-10-2020 15

:

11

Pagina 3 van 9

http://manual.zwave.eu/backend/make.php?lang=en&sku=PHI_PST02-1C

Replace the new battery and install the cover back.

Put the front cover bottom to 1-1, and press down.

Push the front cover top to 2-1.

Choosing a Suitable Location

The recommended mounting height is 160cm

Don"t let the device facing the window or the sunlight.

Don"t let the device facing the source of heat. For instance the heater or the air-condition.

Installation

In the first time, add the device into the Z-WaveTM network. First, make sure the primary controller is in the inclusion mode. And then power on the devi
take out the insulation Mylar in the back side of the device. The device will auto start the NWI (Network Wide Inclusion) mode. And it should be included
seconds. You will see the LED light ON one second. 

Let the controller associate with the device into the first group, any light switch that intend to be turned on when the device trig please associate with the
into the second group. 

In the accessory pack. There are two type of double coated tape, one is thicker (hereinafter referred to as A tape) and another is thinner (hereinafter refe
as B tape), you can use A tape for the test at the beginning. The right way for A tape installation is stick it to the position below tamper key. The thicker ta

Summary of Contents for PHI PST02-1C

Page 1: ...ing every message two way communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter This device and every other certified Z Wave device can be used together with any other certified Z Wave device regardless of brand and origin as long as both are suited for the same frequency range If a devi...

Page 2: ... to make sure the very device is excluded properly from this network Reset to factory default This device also allows to be reset without any involvement of a Z Wave controller This procedure should only be used when the primary controller is inope 1 Pressing tamper key four times within 1 5 seconds and do not release the tamper key in the 4th pressed and the LED will light ON 2 After 3 seconds th...

Page 3: ...ntroller is in the inclusion mode And then power on the devi take out the insulation Mylar in the back side of the device The device will auto start the NWI Network Wide Inclusion mode And it should be included seconds You will see the LED light ON one second Let the controller associate with the device into the first group any light switch that intend to be turned on when the device trig please as...

Page 4: ...r entered exclusion mode 2 Pressing tamper key three times within 1 5 seconds to enter the exclusion mode 3 Node ID has been excluded Node Information Frame The Node Information Frame NIF is the business card of a Z Wave device It contains information about the device type and the technical capabilities The and exclusion of the device is confirmed by sending out a Node Information Frame Beside this...

Page 5: ...n one device controlling another device is called association In order to control a dif device the controlling device needs to maintain a list of devices that will receive controlling commands These lists are called association groups and they a related to certain events e g button pressed sensor triggers In case the event happens all devices stored in the respective association group will rece sa...

Page 6: ...erve 4 Reserve 8 Reserve 16 Disable delay 5 seconds to turn off the light when door window closed 1 Disable 0 Enable 32 Disable auto turn off the light after door window opened to turn on the light 1 Disable 0 Enable 64 Reserve 128 Reserve Parameter 7 Customer Function Customer function switch using bit control Size 1 Byte Default Value 4 Setting Description 1 Reserve 2 Reserve 4 Reserve 8 Disable...

Page 7: ...etting Description 0 127 Auto Report Illumination Time Parameter 13 Auto Report Temperature Time The interval time for auto report the temperature 0 means turn off auto report temperature The default value is 12 The tick time can setting by the configura Size 1 Byte Default Value 12 Setting Description 0 127 Auto Report Temperature Time Parameter 20 Auto Report Tick Interval The interval time for a...

Page 8: ... ZC10 14080018 Z Wave Product Id 0x013C 0x0002 0x000E Frequency Europe 868 4 Mhz Maximum transmission power 5 mW Supported Command Classes Association Association Group Information Battery Sensor Binary Configuration Device Reset Locally Firmware Update Md Manufacturer Specific Multi Command Sensor Multilevel Notification Powerlevel Security Version Wake Up Zwaveplus Info Controlled Command Classes B...

Page 9: ... removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to announces that is able to communicate Node Information Frame is a special wireless message issued by a Z Wave device to announce its capabilities and functions c 2020 Z Wave Europe GmbH Ant...

Reviews: