Philio PHI PST02-1C Quick Start Manual Download Page 2

06-10-2020 15

:

11

Pagina 2 van 9

http://manual.zwave.eu/backend/make.php?lang=en&sku=PHI_PST02-1C

send temperature and brightness value.

Features:

Contact sensor monitors door and window status (open/closed)

Measures and reports additional values for temperature and brightness

Tamper protection

Can be mounted on every planar surface in vertical or horizontal position

Firmware update „Over The Air“ (OTA)

Power Supply: Batterie (1x CR123A)

Wireless Technology: Z-Wave Plus

Dimensions: 28 x 95 x 35 mm

 

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it 

must be in factory default state.

 Please make sure to reset the device into factory default. You ca

by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommend
the primary controller of the previous network to make sure the very device is excluded properly from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inope

1.  Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4th pressed, and the LED will light ON.
2.  After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise

will flash once. 

3.  IDs are excluded and all settings will reset to factory default.

.

Safety Warning for Batteries

The product contains batteries. Please remove the batteries when the device is not used. Do not mix batteries of different charging level or different brands.

Installation

Battery Installation

When the device report the low battery message. The user should replace the battery to new one. The battery type is CR123A, 3.0V. The way to open the f
please follow below steps. 

Using a tool to press the 1-1 position, to release the cover.

Hold the front cover and pull back

Hold the front cover and pull up

Summary of Contents for PHI PST02-1C

Page 1: ...ing every message two way communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter This device and every other certified Z Wave device can be used together with any other certified Z Wave device regardless of brand and origin as long as both are suited for the same frequency range If a devi...

Page 2: ... to make sure the very device is excluded properly from this network Reset to factory default This device also allows to be reset without any involvement of a Z Wave controller This procedure should only be used when the primary controller is inope 1 Pressing tamper key four times within 1 5 seconds and do not release the tamper key in the 4th pressed and the LED will light ON 2 After 3 seconds th...

Page 3: ...ntroller is in the inclusion mode And then power on the devi take out the insulation Mylar in the back side of the device The device will auto start the NWI Network Wide Inclusion mode And it should be included seconds You will see the LED light ON one second Let the controller associate with the device into the first group any light switch that intend to be turned on when the device trig please as...

Page 4: ...r entered exclusion mode 2 Pressing tamper key three times within 1 5 seconds to enter the exclusion mode 3 Node ID has been excluded Node Information Frame The Node Information Frame NIF is the business card of a Z Wave device It contains information about the device type and the technical capabilities The and exclusion of the device is confirmed by sending out a Node Information Frame Beside this...

Page 5: ...n one device controlling another device is called association In order to control a dif device the controlling device needs to maintain a list of devices that will receive controlling commands These lists are called association groups and they a related to certain events e g button pressed sensor triggers In case the event happens all devices stored in the respective association group will rece sa...

Page 6: ...erve 4 Reserve 8 Reserve 16 Disable delay 5 seconds to turn off the light when door window closed 1 Disable 0 Enable 32 Disable auto turn off the light after door window opened to turn on the light 1 Disable 0 Enable 64 Reserve 128 Reserve Parameter 7 Customer Function Customer function switch using bit control Size 1 Byte Default Value 4 Setting Description 1 Reserve 2 Reserve 4 Reserve 8 Disable...

Page 7: ...etting Description 0 127 Auto Report Illumination Time Parameter 13 Auto Report Temperature Time The interval time for auto report the temperature 0 means turn off auto report temperature The default value is 12 The tick time can setting by the configura Size 1 Byte Default Value 12 Setting Description 0 127 Auto Report Temperature Time Parameter 20 Auto Report Tick Interval The interval time for a...

Page 8: ... ZC10 14080018 Z Wave Product Id 0x013C 0x0002 0x000E Frequency Europe 868 4 Mhz Maximum transmission power 5 mW Supported Command Classes Association Association Group Information Battery Sensor Binary Configuration Device Reset Locally Firmware Update Md Manufacturer Specific Multi Command Sensor Multilevel Notification Powerlevel Security Version Wake Up Zwaveplus Info Controlled Command Classes B...

Page 9: ... removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to announces that is able to communicate Node Information Frame is a special wireless message issued by a Z Wave device to announce its capabilities and functions c 2020 Z Wave Europe GmbH Ant...