Philio PHI PAN06 Quick Start Download Page 4

6-7-2020

manual.zwave.eu/backend/make.php?lang=en&sku=PHI_PAN06

manual.zwave.eu/backend/make.php?lang=en&sku=PHI_PAN06

4/5

Setting

Description

0

Switch off

1

ignore

2

Switch toggle

3

Switch on

Parameter 6: Existence of Endpoint3

The endpoint3 of Multi-Channel Command Class is related to relay1 and relay2. It may be redundant for the need to control relay1 or relay2 individually. When

the Existence of Endpoint3 is set as 0, the endpoint3 of Multi-Channel Command Class will be disabled. 

Size: 1 Byte, Default Value: 1

Setting

Description

1

Endpoint3 exist

2

No Endpoint3

Technical Data

Dimensions

0.0470000x0.0390000x0.0160000 mm

Weight

40 gr

Hardware Platform

SD3502

EAN

4713698571160

IP Class

IP 20

Voltage

230 Der Endpunkt3 der Mehrkanal-Befehlsklasse bezieht sich auf Relais1 und Relais2. Es kann überflüssig

sein, die Notwendigkeit, Relais1 oder Relais2 einzeln zu steuern. Wenn die Existenz von Endpunkt3 als 0

gesetzt ist, wird der Endpunkt3 der Mehrkanal-Befehlsklasse deaktiviert.

Load

2x 1500W

Device Type

On/Off Power Switch

Generic Device Class

Binary Switch

Specific Device Class

Binary Power Switch

Firmware Version

01.08

Z-Wave Version

03.5f

Certification ID

ZC10-14120009

Z-Wave Product Id

0x013c.0x0001.0x0013

Frequency

Europe - 868,4 Mhz

Maximum transmission power

5 mW

Supported Command Classes

Basic
Switch Binary
Switch All
Scene Activation
Scene Actuator Conf
Association Grp Info
Device Reset Locally
Zwaveplus Info
Multi Channel
Configuration
Alarm
Manufacturer Specific
Powerlevel

Summary of Contents for PHI PAN06

Page 1: ...security Otherwise it will automatically turn into a lower level of security to maintain backward compatibility For more information about Z Wave technology devices white papers etc please refer to www z wave info Product Description This Insert Switch allows controlling two independent loads both wirelessly via Z Wave and locally utilizing a traditional wall switch Thanks to its calibration techn...

Page 2: ...xternally connected switch Three different modes are supported Edge Mode Die Position of the external switch determines the switching state of the relay After a wireless switching command it may be needed to operate the switch twice to return to the direct relation of switch position and relay state This mode is the factory default mode Toogle Mode Each ON Position of the external switch will togg...

Page 3: ... needs or unlock further enhanced features IMPORTANT Controllers may only allow configuring signed values In order to set values in the range 128 255 the value sent in the application shall be the desired value minus 256 For example To set a parameter to 200 it may be needed to set a value of 200 minus 256 minus 56 In case of a two byte value the same logic applies Values greater than 32768 may nee...

Page 4: ...are Platform SD3502 EAN 4713698571160 IP Class IP 20 Voltage 230 Der Endpunkt3 der Mehrkanal Befehlsklasse bezieht sich auf Relais1 und Relais2 Es kann überflüssig sein die Notwendigkeit Relais1 oder Relais2 einzeln zu steuern Wenn die Existenz von Endpunkt3 als 0 gesetzt ist wird der Endpunkt3 der Mehrkanal Befehlsklasse deaktiviert Load 2x 1500W Device Type On Off Power Switch Generic Device Clas...

Page 5: ... primary controller in a Z Wave network Inclusion is the process of adding new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to announces that is able to communicate Node Informatio...

Reviews: