happens all devices stored in the respective association group will receive a common wireless command.

Association Groups:

1 Relay 1 and 2 together (max. nodes in group: 1)

2 Relay 1 (max. nodes in group: 1)

3 Relay 2 (max. nodes in group: 1)

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can 

adapt the function better to user needs or unlock further enhanced features.

IMPORTANT: Controllers may only allow to configure signed values. In order to set values in the range 128 

… 255 the value sent in the application shall be the desired value minus 256. For example: to set a 

parameter to 200? it may be needed to set a value of 200 minus 256 = minus 56. In case of two byte value 

the same logic applies: Values greater than 32768 may needed to be given as negative values too.

W meter report period (Parameter Number 1, Parameter Size 2) If the setting is configured for 1hour (set 

value =720), the device will report its instant power consumption every 1 hour to Z-Wave Controller. Unit: 5 

seconds

Value

Description

1 — 32000 seconds (Default 720)

KWH meter report period (Parameter Number 2, Parameter Size 2) If the setting is configured for 1hour (set 

value =720), the device will report its power consumption in KWh every 1 hour to Z-Wave Controller. Unit: 5 

seconds

Value

Description

1 — 32000 seconds (Default 6)

Selected end point (Parameter Number 3, Parameter Size 1) defines the relays selected

Value

Description

1

Relay 1 and Relay 2 (Default)

2 — 3 Relay 1

3 — 4 Relay 2

 5 

Summary of Contents for PHI PAN04

Page 1: ...is the international standard for wireless communication in smart homes and buildings It is using the frequency of 868 42 MHz to realize a very stable and secure communication Each message is reconfirmed two way communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter Z Wave differentiate...

Page 2: ...switch module has a power meter function and is able to measure instant power voltage current power factor and accumulated power consumption In addition to this the device has an overload protection The device is placed in a wall box right behind the normal switch The switch is not longer directly connected to the load but acts as input device for the insert that is controlling the load This devic...

Page 3: ...sion Devices can also leave a network This process is called Exclusion Both processes are initiated by the primary controller of the Z Wave network This controller will be turned into exclusion respective inclusion mode Please refer to your primary controllers manual on how to turn your controller into inclusion or exclusion mode Only if the primary controller is in inclusion or exclusion mode thi...

Page 4: ...ults in a change of the relay state Remote Operation Remote On Off control of the switch is possible with any Z Wave controller Further you can set associations to let your device controlled by other Z Wave devices like sensors The switch is able to detect the current wattage 5 1500W and overload wattage 1600 1700W of connected loads When detecting overload state the switch will be disabled and th...

Page 5: ...t may be needed to set a value of 200 minus 256 minus 56 In case of two byte value the same logic applies Values greater than 32768 may needed to be given as negative values too W meter report period Parameter Number 1 Parameter Size 2 If the setting is configured for 1hour set value 720 the device will report its instant power consumption every 1 hour to Z Wave Controller Unit 5 seconds Value Des...

Page 6: ... Number 5 Parameter Size 2 Value Description 1 1500 W Default 1500 Threshold of KWH for Load Caution Parameter Number 6 Parameter Size 2 Value Description 1 10000 kWh Default 10000 Command Classes Supported Command Classes Basic version 1 Alarm version 1 Association version 1 Binary Switch version 1 Configuration version 1 Manufacturer Specific version 1 Meter version 1 Multi Channel version 1 All...

Page 7: ...ocess of bringing new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to annonces that is is able to communicate Node Information Frame is a special wireless message issued by a Z_Wa...

Reviews: