1. Controllers control actuators
2. Actuators report change of status back to controller
3. Sensors report change of status of measured values to controller
4. Sensors directly control actuators
5. Actuators control other actuators
6. Remote controls send signals to static controllers to trigger scenes or other actions
7. Remote controls control other actuators.

There are two different role a controller can have. There is always one single primary controller that is managing the 

network and including/excluding devices. The controller may have other functions - like control buttons - as well. All other 

controllers don't manage the network itself but can control other devices. They are called secondary controllers. The 

image also shows that its not possible to operate a sensor just from a remote control. Sensors only communicate with 

static controllers.

Product description

This Insert Switch allows controlling two independent loads both wirelessly via Z-Wave and locally utilizing a 

traditional wall switch. Thanks to its calibration technology the device cannot only be used to switch resistive 

devices but also works perfectly with many kind of reactive or resistive loads such as fluorescent lights or 

LEDs. This insert switch module has a power meter function and is able to measure instant power, voltage, 

current, power factor and accumulated power consumption. In addition to this, the device has an overload 

protection. The device is placed in a wall box right behind the normal switch. The switch is not longer directly 

connected to the load but acts as input device for the insert that is controlling the load. This device is 

designed for a 3 wire system and needs a neutral wire in the wall box.

Before Device is installed

Please read carefully the enclosed user manual before installation of the radio-actuator, in order to ensure 

an error-free functioning.

ATTENTION: only authorized technicians under consideration of the country-specific installation 

guidelines/norms may do works with 230?Volt mains power. Prior to the assembly of the product, the 

voltage network has to be switched off and ensured against re-switching.

The product is permitted only for proper use as specified in the user manual. Any kind of guarantee claim 

has to be forfeited if changes, modifications or painting are undertaken. The product must be checked for 

damages immediately after unpacking. In the case of damages, the product must not be operated in any 

case. If a danger-free operation of the equipment cannot be assured, the voltage supply has to be 

interrupted immediately and the equipment has to be protected from unintended operation.

Installation Guidelines

 

Summary of Contents for PHI PAN04

Page 1: ...is the international standard for wireless communication in smart homes and buildings It is using the frequency of 868 42 MHz to realize a very stable and secure communication Each message is reconfirmed two way communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter Z Wave differentiate...

Page 2: ...switch module has a power meter function and is able to measure instant power voltage current power factor and accumulated power consumption In addition to this the device has an overload protection The device is placed in a wall box right behind the normal switch The switch is not longer directly connected to the load but acts as input device for the insert that is controlling the load This devic...

Page 3: ...sion Devices can also leave a network This process is called Exclusion Both processes are initiated by the primary controller of the Z Wave network This controller will be turned into exclusion respective inclusion mode Please refer to your primary controllers manual on how to turn your controller into inclusion or exclusion mode Only if the primary controller is in inclusion or exclusion mode thi...

Page 4: ...ults in a change of the relay state Remote Operation Remote On Off control of the switch is possible with any Z Wave controller Further you can set associations to let your device controlled by other Z Wave devices like sensors The switch is able to detect the current wattage 5 1500W and overload wattage 1600 1700W of connected loads When detecting overload state the switch will be disabled and th...

Page 5: ...t may be needed to set a value of 200 minus 256 minus 56 In case of two byte value the same logic applies Values greater than 32768 may needed to be given as negative values too W meter report period Parameter Number 1 Parameter Size 2 If the setting is configured for 1hour set value 720 the device will report its instant power consumption every 1 hour to Z Wave Controller Unit 5 seconds Value Des...

Page 6: ... Number 5 Parameter Size 2 Value Description 1 1500 W Default 1500 Threshold of KWH for Load Caution Parameter Number 6 Parameter Size 2 Value Description 1 10000 kWh Default 10000 Command Classes Supported Command Classes Basic version 1 Alarm version 1 Association version 1 Binary Switch version 1 Configuration version 1 Manufacturer Specific version 1 Meter version 1 Multi Channel version 1 All...

Page 7: ...ocess of bringing new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to annonces that is is able to communicate Node Information Frame is a special wireless message issued by a Z_Wa...

Reviews: