background image

3.

IDs are excluded.

SmartStart

1. Product has a DSK string, you can key

in first five digit to increment smart 
start process, or you can scan QR 
code.

Ex: mydsk
10209-46687-52248-13629-04783-

07465-15776-56519

2. SmartStart enabled products can be 

added into a Z-Wave network by 
scanning the Z-Wave QR Code 
present on the product providing 
SmartStart inclusion. No further 
action is required and the SmartStart
product will be added automatically 
within 10 minutes of minutes On in 
the network vicinity.

Association

This machine provides a group of groups.
Each group can set 5 Nodes.
Group 1: Used for event return.
Report type:
1.Notification report
2.Sensor multilevel report
3.Reset report

Adding a node ID allocated by Z-Wave Controller means inclusion. Removing a node

ID allocated by Z-Wave Controller means exclusion.

Failed or success in including/excluding the node ID can be viewed from the Z-Wave 

Controller.

LED Indication

To distinguish what mode the switch is in, view from the LED for identification.

State Type

LED Indication

No node ID

Under normal operation, when the Switch has not been allocated a node ID, 
the LED flashes on and off alternately at 30 second intervals. By pressing 
On/Off button, it will stop flashing temporarily.

Learning

When PAT12 is in learning mode, If the learning code is successful, the LED 
will flash slowly.

                                                                     

Programming

2. Z-Wave’s Configuration

Configuration
Parameter

Function

Size
(Byte)

Value

Unit

Default

Description

1

Fixed timer for 
report Co2 
concentration    

1

0-127

1

Units of 1 minutes.

2

Concentration 
change report

1

0-100

10

Units of 1 %.

3

Baseline level 1 1

0-50

6

Units of 100 ppm.

4

Baseline level 2 1

0-50

8

Units of 100 ppm.

5

Baseline level 3 1

0-50

10

Units of 100 ppm.

6

Baseline level 4 1

0-50

12

Units of 100 ppm.

7

Baseline level 5 1

0-50

16

Units of 100 ppm.

2. Firmware update over the air (OTA)

PAT12 

is based on 500 series SoC and supports Firmware Update Command 

Class, it can receives the updated firmware image sent by controller via the Z-
wave RF media. It is a helpful and convenient way to improve some function if 
needed.

Command Classes

2

Summary of Contents for PAT12

Page 1: ...d in any Z Wave network with other Z Wave certified devices from other manufacturers All non battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network The table below lists an operation summary of basic Z Wave functions Please refer to the instructions for your Z WaveTM Certificated Primary Controller to access the Setup function an...

Page 2: ... mode the switch is in view from the LED for identification State Type LED Indication No node ID Under normal operation when the Switch has not been allocated a node ID the LED flashes on and off alternately at 30 second intervals By pressing On Off button it will stop flashing temporarily Learning When PAT12 is in learning mode If the learning code is successful the LED will flash slowly Programm...

Page 3: ...tarting the update please remove the front case of the device otherwise the hardware check will fail Let the controller into firmware update mode and press the front tamper key once to start the update After firmware download is completed the LED light will flash intermittently Overview Specification Rated Voltage DC5V from USB Range Minimum 40M in door and 100M in outdoor line of sight Operating ...

Page 4: ... by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help...

Reviews: