Philio PAT02-A User Manual Download Page 9

FCC Interference Statement 

This equipment has been tested and found to comply with the limits for

a Class B digital device, pursuant to Part 15 of the FCC Rules. These

limits are designed to provide reasonable protection against harmful

interference in a residential installation. This equipment generates, uses

and can radiate radio frequency energy and, if not installed and used in

accordance with the instructions,   may cause harmful interference to

radio   communications.         However,     there   is   no   guarantee   that

interference will not occur in a particular installation.  If this equipment

does cause harmful interference to radio or television reception,  which

can be determined by turning the equipment off and on,  the user is

encouraged to try to correct the interference by one of the following

measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from

that to which the receiver is connected.

Consult   the   dealer   or   an   experienced   radio/TV   technician   for

help.

This device complies with Part 15 of the FCC Rules. Operation is subject

to the following two conditions: 

(1) This device may not cause harmful interference, and

(2)   This   device   must   accept   any   interference   received,   including

interference that may cause undesired operation. 

 

FCC Caution: Any changes or modifications not expressly approved by

the party responsible for compliance could void the user's authority to

operate this equipment. 

 

This transmitter must not be  co-located or  operating in  conjunction

with any other antenna or transmitter.

Warning

Do not dispose of electrical appliances as unsorted municipal waste,

use   separate   collection   facilities.   Contact   your   local   government   for

information   regarding   the   collection   systems   available.   If   electrical

appliances are disposed of in landfills or dumps, hazardous substances

can leak into the groundwater and get into the food chain, damaging

your health and well-being.

When replacing old appliances with new once, the retailer is legally

obligated to take back your old appliance for disposal at least for free

of charge.

9

Summary of Contents for PAT02-A

Page 1: ...The device adopt the Z WaveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed speed up communication Function Compare A B C Flood Temperature Humidity PAT02 ...

Page 2: ...oup 2 is for the light control the device will send the Basic Set command to this group And each group support 8 nodes maximum Failed or success in add remove the node ID can be viewed from Z WaveTM Controller Notice 1 Always RESET a Z WaveTM device before trying to add it to a Z WaveTM network Notice 2 When the device into NWI mode the sensor functionality will useless The NWI mode will timeout a...

Page 3: ...to disable this function by setting the configuration NO 21 to 0 In the default when the temperature is changed to plus or minus one degree Fahrenheit 0 56 degree Celsius the device will report temperature information to the nodes in the group 1 The device will measure the temperature in every 10 seconds And if the temperature is over 140 degree Fahrenheit 60 degree Celsius the device will always ...

Page 4: ...seconds Until timeout or the device successful to inclusion by controller The use can presses the tamper key 3 times to abort the NWI mode PS If the device already adding to the network the device will broadcast a node information once Wake When the device power on the device will wake about 20 seconds In this duration the controller can communicate with the device Normally the device is always sl...

Page 5: ... The way to open the front cover please press the top position to release the cover Replace the new battery and install the cover back 1 Put the front cover bottom and press down 2 Push the front cover top Installation 1 To mount the device on the wall you can choose using the tape or the screw 2 Using the screw to fix the flood detector 5 1 1 2 ...

Page 6: ... 0x00 send the BASIC CC to the group 2 2 Basic Set ON Level 0xFF All Setting the BASIC command value When the flood trigger on 0xFF send the BASIC CC to the group 2 5 Operation Mode All 0 33 32 Operation mode Using bit to control 0 Bit0 Disable the Flood function 0 Bit1 Reserve 0 Bit2 Reserve 0 Bit3 Setting the temperature scale 0 Fahrenheit 1 Celsius 0 Bit4 Reserve 0 Bit5 Disable the temperature ...

Page 7: ...emperatur e Time 12 0 127 The interval time for auto report the temperature 0 means turn off auto report The default value is 12 The tick time can setting by the configuration No 20 14 Auto Report Humidity Time 12 0 127 The interval time for auto report the humidity 0 means turn off auto report The default value is 12 The tick time can setting by the configuration No 20 15 Auto Report Flood Time 1...

Page 8: ... COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_SENSOR_BINARY_V2 COMMAND_CLASS_SENSOR_MULTILEVEL_V5 COMMAND_CLASS_WAKE_UP_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_MULTI_CMD COMMAND_CLASS_SECURITY COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 Specifications Power by CR123A lithium battery Signal Frequency 868 40 MHz 869 85 MHz EU 908 40 MHz 916 0...

Page 9: ... to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modi...

Reviews: