background image

NO.

Name

Def.

Valid

A B C

Description

0

  

Bit4

: Reserve.

0

  

Bit5

: Reserve.

0

  

Bit6

: Disable the humidity report after

event triggered.  (1:Disable, 0:Enable)

0

  

Bit7

: Reserve.

7

(*)

Customer

Function

All

0

0

0

Customer function switch, using bit 
control.

0

  

Bit0

: Reserve.

0

  

Bit1

: Reserve.

0

  

Bit2

: Reserve.

0

  

Bit3

: Disable send out BASIC OFF 

after the flood event cleared. 
(1:Disable, 0:Enable)

0

  

Bit4

: Notification Type,  

        0: Using Notification Report. 
        1: Using Sensor Binary Report.

0

  

Bit5

: Disable Multi CC in auto report. 

(1:Disable, 0:Enable)

0

  

Bit6

: Disable to report battery state 

when the device triggered. (1:Disable, 
0:Enable)

0

  

Bit7

: Reserve.

10 Auto 

Report 

Battery 

12

0 ~
127

  

The interval time for auto report the 
battery level. 
0 means turn off auto report.

NO.

Name

Def.

Valid

A B C

Description

Time

The default value is 12. The tick time 
can setting by the configuration No.20.

13

Auto Report
Temperatur
e Time

12

0 ~
127

  

The interval time for auto report the 
temperature. 
0 means turn off auto report.
The default value is 12. The tick time 
can setting by the configuration No.20.

14

Auto Report
Humidity 
Time

12

0 ~
127

  

The interval time for auto report the 
humidity. 
0 means turn off auto report.
The default value is 12. The tick time 
can setting by the configuration No.20.

15

Auto Report
Flood Time

12

0 ~
127

  

The interval time for auto report the 
flood state. 
0 means turn off auto report.
The default value is 12. The tick time 
can setting by the configuration No.20.

20

Auto Report
Tick 
Interval

30

0 ~

0xFF

  

The interval time for auto report each 
tick. Setting this configuration will 
effect configuration No.10, No.13, 
No.14 and No.15.
Units of one minute.

Caution1

Setting to 

0

 means turn off

all auto report function.

Caution2

: The value is unsigned byte

21

Temperature

 

Differential 
Report

1

0 ~

0x7F

  

The temperature differential to report.
0 means turn off this function. 
The unit is Fahrenheit.
Enable this function the device will 
detect every 

10 seconds

7

Summary of Contents for PAT02-A

Page 1: ...The device adopt the Z WaveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed speed up communication Function Compare A B C Flood Temperature Humidity PAT02 ...

Page 2: ...oup 2 is for the light control the device will send the Basic Set command to this group And each group support 8 nodes maximum Failed or success in add remove the node ID can be viewed from Z WaveTM Controller Notice 1 Always RESET a Z WaveTM device before trying to add it to a Z WaveTM network Notice 2 When the device into NWI mode the sensor functionality will useless The NWI mode will timeout a...

Page 3: ...to disable this function by setting the configuration NO 21 to 0 In the default when the temperature is changed to plus or minus one degree Fahrenheit 0 56 degree Celsius the device will report temperature information to the nodes in the group 1 The device will measure the temperature in every 10 seconds And if the temperature is over 140 degree Fahrenheit 60 degree Celsius the device will always ...

Page 4: ...seconds Until timeout or the device successful to inclusion by controller The use can presses the tamper key 3 times to abort the NWI mode PS If the device already adding to the network the device will broadcast a node information once Wake When the device power on the device will wake about 20 seconds In this duration the controller can communicate with the device Normally the device is always sl...

Page 5: ... The way to open the front cover please press the top position to release the cover Replace the new battery and install the cover back 1 Put the front cover bottom and press down 2 Push the front cover top Installation 1 To mount the device on the wall you can choose using the tape or the screw 2 Using the screw to fix the flood detector 5 1 1 2 ...

Page 6: ... 0x00 send the BASIC CC to the group 2 2 Basic Set ON Level 0xFF All Setting the BASIC command value When the flood trigger on 0xFF send the BASIC CC to the group 2 5 Operation Mode All 0 33 32 Operation mode Using bit to control 0 Bit0 Disable the Flood function 0 Bit1 Reserve 0 Bit2 Reserve 0 Bit3 Setting the temperature scale 0 Fahrenheit 1 Celsius 0 Bit4 Reserve 0 Bit5 Disable the temperature ...

Page 7: ...emperatur e Time 12 0 127 The interval time for auto report the temperature 0 means turn off auto report The default value is 12 The tick time can setting by the configuration No 20 14 Auto Report Humidity Time 12 0 127 The interval time for auto report the humidity 0 means turn off auto report The default value is 12 The tick time can setting by the configuration No 20 15 Auto Report Flood Time 1...

Page 8: ... COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_SENSOR_BINARY_V2 COMMAND_CLASS_SENSOR_MULTILEVEL_V5 COMMAND_CLASS_WAKE_UP_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_MULTI_CMD COMMAND_CLASS_SECURITY COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 Specifications Power by CR123A lithium battery Signal Frequency 868 40 MHz 869 85 MHz EU 908 40 MHz 916 0...

Page 9: ... to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modi...

Reviews: