NO.
Name
Def.
Valid
A B C
Description
0
Bit4
: Reserve.
0
Bit5
: Reserve.
0
Bit6
: Disable the humidity report after
event triggered. (1:Disable, 0:Enable)
0
Bit7
: Reserve.
7
(*)
Customer
Function
All
0
0
0
Customer function switch, using bit
control.
0
Bit0
: Reserve.
0
Bit1
: Reserve.
0
Bit2
: Reserve.
0
Bit3
: Disable send out BASIC OFF
after the flood event cleared.
(1:Disable, 0:Enable)
0
Bit4
: Notification Type,
0: Using Notification Report.
1: Using Sensor Binary Report.
0
Bit5
: Disable Multi CC in auto report.
(1:Disable, 0:Enable)
0
Bit6
: Disable to report battery state
when the device triggered. (1:Disable,
0:Enable)
0
Bit7
: Reserve.
10 Auto
Report
Battery
12
0 ~
127
The interval time for auto report the
battery level.
0 means turn off auto report.
NO.
Name
Def.
Valid
A B C
Description
Time
The default value is 12. The tick time
can setting by the configuration No.20.
13
Auto Report
Temperatur
e Time
12
0 ~
127
The interval time for auto report the
temperature.
0 means turn off auto report.
The default value is 12. The tick time
can setting by the configuration No.20.
14
Auto Report
Humidity
Time
12
0 ~
127
The interval time for auto report the
humidity.
0 means turn off auto report.
The default value is 12. The tick time
can setting by the configuration No.20.
15
Auto Report
Flood Time
12
0 ~
127
The interval time for auto report the
flood state.
0 means turn off auto report.
The default value is 12. The tick time
can setting by the configuration No.20.
20
Auto Report
Tick
Interval
30
0 ~
0xFF
The interval time for auto report each
tick. Setting this configuration will
effect configuration No.10, No.13,
No.14 and No.15.
Units of one minute.
Caution1
:
Setting to
0
means turn off
all auto report function.
Caution2
: The value is unsigned byte
21
Temperature
Differential
Report
1
0 ~
0x7F
The temperature differential to report.
0 means turn off this function.
The unit is Fahrenheit.
Enable this function the device will
detect every
10 seconds
.
7