  When S1 is short pressed, the shutter will move up toward TOP(0x63). While in 

this moving S1 is short pressed again, the shutter will stop moving. A third short 

pressing of S1 will move the shutter down toward BOTTOM(0x00). While in this 

moving S1 is short pressed again, the shutter will stop moving. And so on… 

Inverting direction and stopping.

5-2-2 Two Push Button

 (The default setting is Two Push Button (2))

If this setting is configured as Two Push Button, S1 and S2 input will be valid, but

will not accept pressing S1and S2 at the same time. In this switch mode, the 

inclusion/exclusion/reset function can also be fulfilled by pressing S1 or S2 just 

like the operation of include button.

When S1 is pressed and hold more than 1.5 seconds, the shutter will move up 

toward TOP(0x63), and the shutter will stop moving when S1 is released. When 

S2 is pressed and hold more than 1.5 seconds, the shutter will move down 

toward BOTTOM(0x00), and the shutter will stop moving when S2 is released.    

  When S1 is short pressed, the shutter will move up toward TOP(0x63).  While in 

this moving short pressed S1 again, the shutter just keep moving up toward 

TOP(0x63). The easy way to stop this moving is short pressing S2. When S2 is 

short pressed, the shutter will move down toward BOTTOM(0x00). While in this 

moving short pressed S2 again, the shutter just keeps moving down toward 

BOTTOM(0x00). The easy way to stop this moving is short pressing S1.

When in Two Push Button switch mode, S1 or S2 are pressed and not 

released, and PAN34 receive any control moving command from Z-Wave RF

(Ex. 

BASIC_SET

BINARY_SWITCH_SET

MULTILEVEL_SWITCH_SET

MULTILE

VEL_SWITCH_START_LEVEL_CHANGE or 

MULTILEVEL_SWITCH_STOP_LEVEL_CHANGE), PAN34 won’t do any 

change in position.

ATT. : For avoid misunderstanding that RF command dose not work, it is 

recommended to check the status of S1 and S2.

5-3 Total moving time of curtain

 

       This a way for setting the total moving time of curtain manually. You can count 

the time when shutter move from BOTTOM to TOP by long pressing S1 or 

S2. But if the time is set as 0, the total moving time of shutter will be the 

value set by Moving Range Calibration which is describing in Page 3. The 

default value is 0.

5-4 Watt threshold

 

The threshold is for PAN34 judging if the motor is running or not. The default 

value is 1 watt.

5-5 Watt differential

 

Whenever the watt value varies over 5%, PAN34 will send the meter report to 

group 1 nodes. The default value is 1 (5%).

5-6 Timer offset for motor start running

 

This parameter is an offset to count for starting time of the motor. It will improve 

the inaccurate when moving to the middle position. The default value is 50.

 

6.Command Classes

       The Switch supports Command Classes including…

Command Class

Version

Required Security Class

11

Summary of Contents for PAN34

Page 1: ...This device must be used in conjunction with a Security Enabled Z Wave Controller in order to fully utilize all functions Its functionality and supported command classes is identical when included as a secure and non secure device The new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of Roller Shutter This in wa...

Page 2: ...0 MHz 923 10 MHz Taiwan RF Maximum Power 10dBm Peak 10dBm Average Communication Protocol Z Wave OTA Yes FCC ID RHHPAN34 Dimensions 47 5 x 39 x16 mm Wire 0 75mm 18AWG Specifications are subject to change and improvement without notice Troubleshooting Symptom Cause of Failure Recommendation The PAN34 not working and LED off 1 The PAN34 is not connect to the Main power 2 The PAN34 break down 1 Check ...

Page 3: ...ducing changes into the configuration must be always performed with disconnected voltage Choosing a Suitable Location 1 Do not locate the Module facing direct sunlight humid or dusty place 2 The suitable ambient temperature for the Module is 0 C 40 C 3 Do not locate the Module where exists combustible substances or any source of heat e g fires radiators boiler etc 4 After putting it into use the b...

Page 4: ...n mode by following the instructions provided by the controller manufacturer 2 Pressing Include button three times within 2 seconds will enter exclusion mode Node ID has been excluded LED 0 5s On 0 5s Off En ter auto inclusion Reset 1 Pressing Include button three times within 2 seconds will enter inclusion mode Use this procedure only in the event that the primary controller is lost or otherwise ...

Page 5: ... of three continue stages The shutter move to the TOP in first stage and move to the BOTTOM in second stage and move to the TOP again in third stage Then PAN34 will know the total range from the BOTTOM to the TOP 2 During the shutter calibration process any emergencies happen you can press and release the include button to stop the process 3 If user found the direction is reverse this may cause by...

Page 6: ...evel Switch Set Value 0x63 control the shutter to the top 0x63 Command Class Multilevel Switch Multilevel Switch Set Value 0x00 0 control the shutter to the bottom 0x00 Command Class Multilevel Switch Multilevel Switch Set Value 0xFF 255 control the shutter to the the most recent non zero level Command Class Multilevel Switch Multilevel Switch Set Value 0x01 0x62 control the shutter to the positio...

Page 7: ...ome distance error caused by motor start up time 4 If user found the error become significant you may using S1 or S2 move shutter to the end or remote move shutter to 0 and 100 and that will automatically calibrate this error 2 3 4 MULTILEVEL SWITCH STOP LEVEL CHANGE When receive Multilevel Switch Stop Level change Command PAN34 will stop the motor Z Wave s Groups introduction Maximum 5 nodes Ther...

Page 8: ...xample Meter Value 1 0x00 W Meter Value 2 0x00 W Meter Value 3 0x03 W Meter Value 4 0xEA W Meter W Meter Value 3 256 Meter Value 4 100 2W 3 3 2 Accumulated Power Consumption KW h When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Meter Meter Get Scale 0x00 KW h Meter Report Command Command Class Meter Meter Report Rate Type 0x01 M...

Page 9: ... Scale 0x05 I Precision 2 Size 2 2 Bytes of I Meter Value 1 0x01 I Meter Value 2 0x21 I AC load current Meter Value 1 256 Meter Value 2 2 89 A 3 3 5 load power factor PF When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Meter Meter Get Scale 0x06 PF Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0...

Page 10: ...e Push button 2 Two Push button 3 Total 2 0 6000 0 1 Second 0 0 The time depends on Moving Range Calibration moving time of curtain 1 6000 0 1s 600s 4 Watt threshold 1 1 5 Watt 1 The threshold is a judgment for motor running or not 5 Watt differential 1 0 1 1 0 It will not report Watt when change over 5 1 It will report watt value when the differential is over 5 6 Timer offset for motor start runn...

Page 11: ...this moving short pressed S2 again the shutter just keeps moving down toward BOTTOM 0x00 The easy way to stop this moving is short pressing S1 When in Two Push Button switch mode S1 or S2 are pressed and not released and PAN34 receive any control moving command from Z Wave RF Ex BASIC_SET BINARY_SWITCH_SET MULTILEVEL_SWITCH_SET MULTILE VEL_SWITCH_START_LEVEL_CHANGE or MULTILEVEL_SWITCH_STOP_LEVEL_...

Page 12: ...urces To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling Philio Technology Corporation 8F No 653 2 Zhongzheng Rd Xinzhuang Dist New Taipei City 24257 Taiwan R O C www philio tech com FCC Interference Statement This equipment has been tested and found to comply wi...

Page 13: ...erence that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This transmitter must not be co located or operating in conjunction with any other antenna or transmitter 警語 取得審驗證明之低功率射頻器材 非經核准 公司 商號或使用者均不得擅自變更頻 率 加大功率或變更原設計之特性及功能 低功率射頻器材之使用不得影響飛航安全及干擾合法通信 經發現有...

Reviews: