Troubleshooting
Symptom
Cause of Failure
Recommendation
The switch does not work
and the LED is off
1.
The Switch is not
plugged into the
electrical outlet
properly
2.
The Switch break
down
1. Check power connections
2. Don’t open up the Switch and send it
for repair.
The LED illuminates, but
cannot turn ON or OFF the
switch of the load attached
1. Check if the load
plugged into the Switch
has its own ON/OFF
switch
2. Not carry out
association
3. Same frequency
interference
1. Set the ON/OFF switch of the load
attached to ON
2. Carry out association
3.Wait for a while to re-try
LED keep flashing, but
cannot control
Overload occurs
Remove the load attached or check max.
load cannot exceed 16.0A
Situation
Root cause
Solution
No LED indicator
1. No main power
Please check the LN power line and
power outlet
2. PAN27 is broken
Please return to the vender.
LED is normal, but the
device is no action
Please make sure the
device has own switch
Please turn the device to On.
Specification
Operating Voltage
100-240VAC 50/60Hz 16A
Rated Voltage
AC100-240V 50Hz
Output Current
Max.16A
Relay Dongle: 5A (model: ME001)
Dimmer Dongle: 0.7A (model: ME002)
8 independent relay or dimmer outputs
Maximum DC output
DC12V*8
Maximum AC output
16A
Range
Minimum 40 m in door and 100m outdoor; line of sight
Operating Temperature
0°C ~ 40°C (85% humidity)
Storage Temperature
-20 C ~ 60°C
interface
RJ11 (4P2C) for RS485 interface
RJ45 10/100 base-T
USB port
Z-wave 500 series Dongle (operational)
ZigBee Dongle (operational)
Location
Indoor use only
Frequency Range
IEEE 802.11 b/g/n
2412-2472MHz (EU), 2412-2462MHz (USA)
RF power
+17dBm
Dimension
210 (L) x 90(W) x 78 (H) mm
Patent pending