5
2-1 Auto report to Grouping 1 (Maximum Node 1)
2-1-1 On/Off Event Report
When “on” or “off ” state has been changed, it will send Binary Switch Report to the
node of Grouping 1.
Binary Switch Report
ON:[Command Class Switch Binary, Switch Binary Report, Value
=255(0xFF)]
OFF:[Command Class Switch Binary, Switch Binary Report, Value =0(0x00)]
2-1-2 Instant Power Consumption vary over 5% report
When the power consumption of load vary over 5%, it will send Meter report to the
nodes of Grouping 1.
Meter Report Command:
[Command Class Meter
,
,
,
,
Meter Report
,
,
,
,
Rate Type = 0x01
,
,
,
,
Meter Type = 0x01
,
,
,
,
Precision = 1
,
,
,
,
Scale = 0x02
,
,
,
,
Size = 4
,
,
,
,
Meter Value(W) ]
2-1-3 Overload alarm report
When PAN16 detects the current is more than 14.5A, it will send Alarm Report to
Group 1 node.
The content of Alarm Report
Alarm report command:
[Command_Class_Alarm, Alarm_Report, Alarm Type = 0x08, Alarm Level =
0xFF]
2-2 Response to Meter Get Command
The Switch will report its (1) instant Power Consumption (Watt) or (2)
accumulated power consumption(KWH) or (3)
AC load Voltage (V) or (4)
AC load
current ( I ) (5)
load power factor (PF) to Z-Wave Controller after receive the
Meter Get Command from Z-Wave Controller.
2-2-1 Instant Power Consumption (Watt) of Switch
When receiving Meter Get Command, it will report Meter Report Command to the
node.
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x02(W)]
Meter Report Command:
[Command Class Meter
,
,
,
,
Meter Report
,
,
,
,
Rate Type = 0x01
,
,
,
,
Meter Type =
0x01
,
,
,
,
Precision = 1
,
,
,
,
Scale = 0x02
,
,
,
,
Size = 4
,
,
,
,
Meter Value(W) ]
Example:
Meter Value 1 = 0x00 (W)
Meter Value 2 = 0x00 (W)
Meter Value 3 = 0x03 (W)
Meter Value 4 = 0xEA (W)
Meter(W) = Meter Value 3 *256 + Meter Value 4 = 100.2W
2-2-2 Accumulated Power Consumption (KWh)
When receiving Meter Get Command, it will report Meter Report Command to
the node.
Meter Get Command:
[Command Class Meter, Meter Get, Scale = 0x00 KWh)]
Meter Report Command:
[Command Class Meter
,
,
,
,
Meter Report
,
,
,
,
Rate Type = 0x01
,
,
,
,
Meter Type = 0x01
,
,
,
,
Precision = 2
,
,
,
,
Scale = 0x00
,
,
,
,
Size = 4
,
,
,
,
Meter Value (KWh)]
Example:
Scale = 0x00 (KWh)
Precision = 2
Size = 4 Bytes (KWh)
Meter Value 1 = 0x00(KWh)
Meter Value 2 = 0x01(KWh)
Meter Value 3 = 0x38(KWh)
Meter Value 4 = 0xA3(KWh)
Accumulated power consumption (KWh) = (Meter Value 2*65536) + (Meter
Value 3*256) + (Meter Value 4) = 800.35 (KWh)
2-2-3 Clearing accumulated power consumption
Whenever re-start counting the accumulated power consumption is needed, you