1
PAN16
Smart energy plug in switch
Introduction
This plug-in ON/OFF switch PAN16 is a security enabled wireless switch, based on
Z-Wave Plus technology. Z-Wave Plus
TM
enabled devices displaying the Z-Wave
Plus
TM
logo can also be used with it regardless of the manufacturer, and can also be
used in other manufacturer’s Z-Wave
TM
enabled networks. Remote On/Off control of
the connected load is possible with other manufacturer’s wireless Controller. Each
switch is designed to act as a repeater. Repeaters will re-transmit the RF signal to
ensure that the signal is received by its intended destination by routing the signal
around obstacles and radio dead spots. Because PAN16 supports Security Command
Class, it can learn with Secured controller. Its functionality and supported command
classes is identical when included as a secure and non-secure device.
This plug-in ON/OFF switch is able to detect instance wattage (3000W/230Vac)
(13Ampere) and overload current (14.5A with resistive load) of connected lights or
appliances. When detecting overload state, the Switch will be disabled and its On/Off
button will be lockout of which LED will flash quickly. However, unplug and
re-connect the switch will reset its overload condition to normal status.
Warning:
1.Plug out to disconnect from power supply; Do not plug in line.
2. Do not exceed the max rating.
Warnung:
1.Trennen Sie das Gerät von der Stromzuführung. Verwenden Sie das Gerät nicht mit
einem DIP Schalter.
2. Achten Sie darauf, dass die maximale Spannung niemals überschritten wird.
Warnung:
für zwischenstecker:
nicht hintereinander stecken
Specification
Rated Voltage
100V-240Vac 50Hz-60Hz 13A
Maximum Load (Ampere)
13A (Resistive load)
PAN16-1; PAN16-2; PAN16-3
Maximum Load (Ampere)
10A (Resistive load)
PAN16-4
(Switzerland)
Socket Type:
Germany type: PAN16-1
France type: PAN16-2
UK type: PAN16-3
Switzerland type: PAN16-4
Range
Minimum 40 m in door 100m outdoor line of sight
Operating Temperature
0°C - 40°C
Frequency Range
868.40MHz & 869.85MHz for EU (PAN16-1/-2/-3/-4);
RF Maximum Power
+5dBm
** Specifications are subject to change and improvement without notice.
Troubleshooting
Symptom
Cause of Failure
Recommendation
The Switch not working
and LED off
1.
The Switch is not
plugged into the
electrical outlet
properly
2.
The Switch break down
1.
Check power connections
2. Don’t open up the Switch and send it
for repair.
The Switch LED
illuminating, but cannot
1.Check if the load
plugged into the Switch
1. Set the ON/OFF switch of the load
attached to ON