background image

Configuration

Parameter

Function

Size

(Byte)

Value

Unit

Default

Description

1

Watt Meter 

Report  Period

2

0x01-

0x7FFF

5s

720

5*720s=3600s=1 hour

2

KWH Meter 

Report  Period

2

0x01-

0x7FFF

10min

6

6*10min= 1 hour

3

3-1

 Watt 

Meter Report Period:

    If the setting is configured for 1hour (set value =720), the PAN11 will report its

instant power consumption every 1 hour to Z-Wave Controller.   The maximum

interval   to   report   its   instant   power   consumption   is   45   hours

(5s*32767/3600=45hr).

3-2 KWH Meter Report Period:

      If   the  setting  is   configured   for  1hour   (set   value   =6),   the   PAN11  will   report   its

Accumulated Power Consumption (KW/h) every 1 hour to Z-Wave Controller.  The

maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55

days (10min*32767/1440=227.55 days).

4. Command Classes

The Switch supports Command Classes including…

* COMMAND_CLASS_SWITCH_BINARY

* COMMAND_CLASS_BASIC

* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2

* COMMAND_CLASS_VERSION

* COMMAND_CLASS_SWITCH_ALL

* COMMAND_CLASS_ASSOCIATION_V1

* COMMAND_CLASS_METER_V3

* COMMAND_CLASS_CONFIGURATION

Socket Type

Since the socket type for each country in Europe varies, refer to the outline for each 

socket suited for each country as follows:

 Germany type PAN11-1

8

Summary of Contents for PAN11-4

Page 1: ... connect the switch will reset its overload condition to normal status Adding to Z WaveTM Network In the front casing there is an On Off button with LED indicator which is used to toggle switch on and off or carry out inclusion exclusion reset or association When first power is applied its LED flashes on and off alternately and repeatedly at 2 second intervals It implies that it has not been assig...

Page 2: ...three times within 1 5 seconds will enter Press On for on Press Off for off association mode 2 There are only one group for the switch Including a node ID allocated by Z Wave Controller means inclusion Excluding a node ID allocated by Z Wave Controller means exclusion Failed or success in including excluding the node ID can be viewed from the Z Wave Controller LED Indication To distinguish what mo...

Page 3: ...tton The LED will turn ON and the load plugged into the Switch will also turn ON 5 To manually turn OFF the Switch simply press and release the On Off button The LED will turn OFF and the load plugged into the Switch will also turn OFF Programming 1 Basic Command Class Binary Switch Command Class The Switch will respond to BASIC and BINARY commands that are part of the Z Wave system 1 1 BASIC_GET ...

Page 4: ...o Z Wave Controller Grouping 1 includes SWITCH_BINARY_REPORT METER_REPORT_COMMAND 2 1 Auto report to Grouping 1 Maximum Node 1 2 1 1 On Off Event Report When on or off state has been changed it will send Binary Switch Report to the nodes of Grouping 1 Binary Switch Report ON Command Class Switch Binary Switch Binary Report Value 255 0xFF OFF Command Class Switch Binary Switch Binary Report Value 0...

Page 5: ... Value 2 W Meter Value 3 W Meter Value 4 W LSB Example Meter Value 1 0x00 W Meter Value 2 0x00 W Meter Value 3 0x03 W Meter Value 4 0xEA W Meter W Meter Value 3 256 Meter Value 4 100 2W 2 2 2 Accumulated Power Consumption KW h When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x00 KW h Rate Type 0x01 Meter Type 0x...

Page 6: ...t Command Command Class Meter Meter Get Scale 0x04 V Rate Type 0x01 Meter Type 0x01 Precision 1 Scale 0x04 V Size 2 Bytes Meter Value Meter Value 1 High Byte V Meter Value 2 Low Byte V Example Scale 0x04 V Precision 1 Size 2 2 Bytes of V Meter Value 1 0x09 V Meter Value 2 0x01 V AC load Voltage Meter Value 1 256 Meter Value 2 230 5 V 2 2 5 AC load current I When receiving Meter Get Command it will...

Page 7: ...nd to the node Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x06 PF Size 1 Bytes Meter Value 1 Example Scale 0x06 PF Precision 2 Size 1 1 Byte of PF Meter Value 1 0x63 PF Load power factor PF Meter Value 1 0 99 3 Z Wave s Configuration 7 Meter Report Command Command Class Meter Meter Report scale bit 2 Rate Type Meter Type Precision Scale bit 1 0 Size Meter Value 1 Meter Value 2 Meter Get Comm...

Page 8: ... the setting is configured for 1hour set value 6 the PAN11 will report its Accumulated Power Consumption KW h every 1 hour to Z Wave Controller The maximum interval to report its Accumulated Power Consumption KW h is 227 55 days 10min 32767 1440 227 55 days 4 Command Classes The Switch supports Command Classes including COMMAND_CLASS_SWITCH_BINARY COMMAND_CLASS_BASIC COMMAND_CLASS_MANUFACTURER_SPE...

Page 9: ... working and LED off 1 The Switch is not plugged into the electrical outlet properly 2 The Switch break down 1 Check power connections 2 Don t open up the Switch and send it for repair The Switch LED illuminating but cannot control the ON OFF Switch of the load attached Check if the load plugged into the Switch has its own ON OFF switch Set the ON OFF switch of the load attached to ON The Switch L...

Page 10: ...collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling Company of License Holder Philio Technology Corporation Address of License Holder 8F No 653 2 Zhongzheng Rd Xinzhuang Dist New Taipei City 24257 Taiwan R O C FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B...

Page 11: ...peration is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This transmitter must n...

Reviews: