13
Source End Point = 0x05
(this is the endpoint of command owner,
here we assume endpoint is 5
,
if the owner
does not support multi Channel this value
will be 0)
(Bit Destination End Point =
0x03)
(Bit Address =0
;
Destination End Point
range1~3)
Command Class = 0x32
( Command_Class_Meter_V3 = 0x32)
Command =0x01
(Meter_Get = 0x01)
Parameter 1 = 0x30
(Scale = PF = 0x06)
PAN07/PAN09 power factor report example
:
COMMAND_CLASS_MULTI_CHANNEL
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x03
(Meter report = Endpoint3)
(Bit Destination End Point =
0x05)
(Bit Address =0
;
Destination End Point =
command owner Endpoint value)
Command Class = 0x32
(Command_Class_Meter_V3 = 0x32)
Command =0x02
(Meter_Report = 0x02)
Parameter 1 = 0xA1
(Scale Bit2 = 1
,
Rate Type = 0x01
,
Meter Type=0x01)
Parameter 2 = 0x51
(Precision = 2
,
Scale Bit1Bit0 = 0x10
,
Size
= 1)
Parameter 3 = 0x63
Power Factor = 0x63 = 0.99
2. Z-Wave’s Configuration
Configuration
Parameter
Function
Size
(Byte)
Value
Unit
Default
Description
1
Watt Meter
Report
Period
2
0x01-
0x7FFF
5s
720
720*5s=3600s=1
hour
2
KWH
Meter
Report
Period
2
0x01-
0x7FFF
10min
6
6*10min= 1 hour
3
Slected
Relay
1
1-3
3
1
:
Relay1
2
:
Relay2
3
:
Relay1 &
Relay2
4
Edge or
Pulse
mode or
Edge-Toggl
e mode
1
1-3
1
1
:
Edge mode
2
:
Pulse mode
3
:
Edge-Toggle
mode
5
Threshold
of current
for Load
Caution
2
10-600
0.01A
600
600*0.01A = 6.0A
6
Threshold
2
1-10000
1KWh
10000