background image

 
 

PAD02      Z-Wave Smart Dimmer Socket 

 

 

                                                                                           

 

 

 
 

 
 

 
 
 
 

Introduction 

 

PAD02 is an E27(EU)/ E26(US) Edison screw based lamp socket, which provides 

electrical connection to the E14(EU)/ E12(US) Edison screw based lamps and 

 

support it in the lighting fixture. The use of socket allows lamps to be safely and 

 

conveniently replaced. You can On/Off the light by pressing the button briefly, 

 

or a long pressing to control the brightness of dimmable lighbulb.

 

This dimmer is a transceiver which is a security enabled device which based on 

Z-Wave Plus technology. Z-Wave Plus

TM   

enabled devices displaying the Z-Wave

 

Plus

TM

 logo can also be used with it regardless of the manufacturer, and can also be

 

used in other manufacturer’s Z- Wave

TM

 enabled networks. Remote dim level control 

of the connected light is possible with other manufacturer’s wireless Controller.

 

Since PAD02 supports Security Command Class, it can learn with a Secured enabled 

controller to fully utilize the device. Its functionality and supported command classes is 

identical when included as a secure and non-secure device.

 

 

Warning:

 

1. Plug out to disconnect from power supply; Do not plug in line.

 

2. For continued protection against risk of  electric, replace only with same type  and     

rating of fuse.

 

3. Do not connect any appliances other than luminary products.

 

4.  Do  not  connect  any  appliances  to  this  remote  controlled  lampholder  which  are 

radiating  heat  and  may  cause  ignition  or  burning  of  surrounding  materials  (for 

example radiation heaters, portable heaters, portable floodlights, desk lamps, etc).

 

5.  Take  into  consideration  that  connected  appliances  might  be  moved  by  pets, 

cleaning staff or other persons who are not aware of the remote control functions.

 

6.  The  connection/installation  of  this  product  should  be  in  a  suitable  area  with  the 

remote  controlled  lampholder  easily  readable  and  accessible  for  disconnection 

actions.

 

 
Specification

 

Operating Voltage

 

220/ 230/ 240VAC 50/60Hz for EU

 

120VAC 60Hz for US

 

Maximum Load (Wattage)

 

Max. 15 W Type B (for incandescent lamps) 

 

Max.9W Type Dimmable SBLED   

 

Fuse information 

 

Built-in High Breaking Capacity Current Fuse Protection.

 

Rated: 1.25A; 250V

 

Built-in Thermal Cut-off Fuses Protection.

 

Rated Temperature: 125°C; Rated: 2A 250V

 

Screw lampholder Type:

 

EU type: E27 to E14; PAD02-1 

 

US type: E26 to E12; PAD02-2

 

Range

 

Minimum 40m indoor 100m outdoor line of sight

 

Location 

 

Indoor used

 

Operating Temperature

 

0°C to 40°C

 

Frequency Range

 

868.40MHz & 869.85MHz/ EU (PAD02-1); 

 

908.4MHz & 916.0MHz/ USA (PAD02-2);

 

RF Maximum Power

 

+5dBm 

 

FCCID

 

RHHPAD02

 

** Specifications are subject to change and improvement without notice.           

 

Summary of Contents for PAD02

Page 1: ...eplace only with same type and rating of fuse 3 Do not connect any appliances other than luminary products 4 Do not connect any appliances to this remote controlled lampholder which are radiating heat and may cause ignition or burning of surrounding materials for example radiation heaters portable heaters portable floodlights desk lamps etc 5 Take into consideration that connected appliances might...

Page 2: ...h Set the ON OFF switch of the attached load to ON The dimmer LED illuminating but the detector cannot control the dimmer 1 Not carry out association 2 Same frequency interference 1 Carry out association 2 Wait for a while to re try Screw lampholder Type Since the socket type for each country in Europe varies refer to the outline for each socket suited for each country as follows EU TYPE PAD02 1 U...

Page 3: ...econds Unlike inclusion function as shown in the table below the execution of auto inclusion is free from pressing the On Off button on the dimmer The table below lists an operation summary of basic Z Wave functions Please refer to the instructions for your Z WaveTM certificated primary controller to access the setup function and to Add Remove Associate devices Function Description Annotation No n...

Page 4: ...ode ID the LED flashes on and off alternately at 2 second intervals By pressing On Off button it will stop flashing temporarily Learning When PAD02 is in learning mode LED flashes on and off alternately and repeatedly at 0 5 second intervals Manual dim level control To manually switch on the light press and release the On Off button shortly when the light is off The light will dim from off to the ...

Page 5: ...hing to do is unplug PAD02 and reduce the load Then re plug PAD02 and it will work again The content of Alarm Report Alarm report command Command_Class_Alarm Alarm_Report Alarm Type 0x08 Alarm Level 0xFF 2 1 2 Device reset locally notification When PAD02 is reset manually it will send a DEVICE_RESET_LOCALLY_ NOTIFICATION to the nodes of group 1 2 1 3 Multilevel switch report Whenever the level of ...

Page 6: ...MMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_BASIC COMMAND_CLASS_SWITCH_MULTILEVEL_V2 COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_ALARM COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 COMMAND_CLASS_SCENE_ACTIVATION COMMAND_CLASS_SCENE_ACTUATOR_CONF Choosing a Suitable Location 1 Do not locate the dimmer facing direct sunlight humid or dusty place 2 The sui...

Page 7: ...help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s au...