![Philio Technology Corporation PSR07 Manual Download Page 4](http://html.mh-extra.com/html/philio-technology-corporation/psr07/psr07_manual_1538019004.webp)
Firmware update over the air (OTA)
This device supports the Z-Wave firmware update via OTA. Let the
controller into the firmware update mode, and rotate to area A
then touch the button once to start update. After finish the
firmware download, the red LED will start to flash every 0.5 sec-
ond. Please don't remove the battery before the LED stop flashing.
Notice: recommend using OTA when the device is charg-
ing.
Supported Z-Wave Command Classes
* COMMAND_CLASS_ZWAVEPLUS_INFO_V2
* COMMAND_CLASS_BATTERY
* COMMAND_CLASS_CENTRAL_SCENE_V1
* COMMAND_CLASS_VERSION_V2
* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
* COMMAND_CLASS_DEVICE_RESET_LOCALLY
* COMMAND_CLASS_ASSOCIATION_V2
* COMMAND_CLASS_WAKE_UP_V2
* COMMAND_CLASS_ASSOCIATION_GRP_INFO
* COMMAND_CLASS_POWERLEVEL
* COMMAND_CLASS_MULTI_CMD
* COMMAND_CLASS_SECURITY
* COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
* COMMAND_CLASS_CONFIGURATION
Security Network
The device support the security function. When the device
included with a security controller, the device will auto switch to
the security mode. In the security mode, the follow commands
need using Security CC wrapped to communicate, otherwise it will
not response.
COMMAND_CLASS_BATTERY
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_CENTRAL_SCENE
Troubleshooting
Symptom
Cause of Failure
Recommendation
The switch
on/off
function not
working and
LED off
1. Battery is running
out of power
2. Wrong function
mode
1. Charging the battery by
Micro USB.
2. Pointing the arrowhead to
area B and press the
touch button.
3. If the device still can
work, don’t open up the
Switch and send it for
repair.
Can not
adjust the
percentage
of dimmer
1. The device may not
be placed upright.
2. The device is in off
state.
1. Check if the device is
placed upright.
2. Rotating to the
percentage you want
then press touch button.
Or pointing the
arrowhead to area B and
press the touch button to
turn the lamp on then
adjust the percentage.
The device
can not join
to Z-Wave
network
1. The device may in a
Z-Wave network.
2. The arrowhead
points to wrong
area.
1. Exclude the device then
include again.
2. Pointing the arrowhead to
area A then include
again.
4