Philio Technology Corporation PSR07 Manual Download Page 1

PSR07 Smart Color Button

This   device   is   a   multiple   functions   button   switch.   It   is   able   to

switch the appliances on/off or adjust the percentage of dimmer.

It can also work as a timer. The well designed wall bracket and

magnetic back let the switch can be fixed on the wall. This product

can be included and operated in any Z-Wave

TM

 network  with other

Z-Wave

TM

 certified devices from other manufacturers and/or other

applications.

Note:

Please provide a 5 DVC voltage through Micro USB Port to

wake the device up before the first using.

The   rotation   function   and   timer   functions   work   only   when   the

device is fitted upright or stick on the wall or the device will only

work as an on/off switch when fitted horizontal. 

Z-Wave Network Setting Up

In the first time, add the device into the Z-Wave

TM

 network. Make

sure the primary controller is in the add mode. And then power on

the device through micro USB. The device will auto start the NWI

(Network Wide Inclusion). Red LED will flash every second and

continue 30 seconds. And it should be included in 5 seconds. Red

LED will light ON one second. Rotating to area A(shown in Fig. 1)

and touch 3 times can abort NWI mode.

There is a touch button on the front side. The button carries out

manual inclusion, exclusion and reset to default.

1. Include: Pointing the arrowhead to area A first (shown in Fig.

1). Pressing the button three times within 1.5 seconds. The red

LED will light up for 1 second if succeed.

2. Exclude: Pointing the arrowhead to area A first. Pressing the

button three times within 1.5 seconds.

3. Reset   to   default:   Pointing   the   arrowhead   to   area   A   first.

Pressing button four times within 2 seconds and hold at fourth.

The red LED will light for 3 seconds, release the button within

2 seconds while the LED goes out. The LED will flash for 1

second if reset succeed, or LED will flash once

.

Notice

:   Including   a   node   ID   allocated   by   Z-Wave

TM

  Controller

means “

Add

” or “

Inclusion

”.  Excluding a node ID allocated by

Z-Wave

TM

  Controller means “

Remove

” or “

Exclusion

”.

Function

This device can  control dimmers in  group  2 using three ways:

Dimmer, Timer, and Binary Switch. Point the arrowhead to area

A(shown in Fig. 1 and Fig. 2) then hold the button, release after

the red LED go out. One beep means entering Timer mode or two

beeps means entering Dimmer mode. The device can switch to

Binary Switch mode automatically when fitting horizontal.

1

Summary of Contents for PSR07

Page 1: ...econd Rotating to area A shown in Fig 1 and touch 3 times can abort NWI mode There is a touch button on the front side The button carries out manual inclusion exclusion and reset to default 1 Include Pointing the arrowhead to area A first shown in Fig 1 Pressing the button three times within 1 5 seconds The red LED will light up for 1 second if succeed 2 Exclude Pointing the arrowhead to area A fi...

Page 2: ...an rotate PSR07 to area C or touch the button again Timer This mode can time the length of turning Off the light The length is up to 15 minutes When counting down starts surround LED will flash and buzzer will sound according to the remaining time Rotating to area C can cancel counting down directly Timer left Flash color Buzzer 10 15 minutes Cyan 10 seconds 5 10 minutes Green 10 seconds 3 5 minut...

Page 3: ...al minimum set ting is 30 minutes and maximum setting is 120 hours And the in terval step is 30 minutes If the user want to wake up the device immediately please rotate to area A and pressing the touch but ton once The device will wake up for 10 seconds every single time Configuration NO Name Size Byte Def Valid Values Description 1 Basic Set OFF level 1 0x00 0x00 0x63 Control the value represente...

Page 4: ...vice will auto switch to the security mode In the security mode the follow commands need using Security CC wrapped to communicate otherwise it will not response COMMAND_CLASS_BATTERY COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_WAKE_UP_V2 COMMAND_CLASS_CENTRAL_SCENE Troubleshooting Symptom Cause of Failure Recommendation The switch on off function not working and LED off ...

Page 5: ...s or contact the retailer where the product was purchased They can take this product for environmental safe recycling Company of License Holder Philio Technology Corporation Address of License Holder 8F No 653 2 Zhongzheng Rd Xinzhuang Dist New Taipei City 24257 Taiwan R O C FCC Interference Statement This equipment has been tested and found to comply with the lim its for a Class B digital device ...

Page 6: ...eration is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s au thority to operate this equipment This transmitter must n...