Philio Technology Corporation PSP06 Manual Download Page 5

PIR Warm Up

When   the   device   power   on,   the   PIR   need   to   warm   up   before   the
operation.   The   warm   up   time   about   1   minute,   the   LED   will   flash   in
every 2 seconds. After finish the procedure the LED will light ON three
times.

* 

Wake

When the device power on, the device will wake about 20 seconds. In
this duration, the controller can communicate with the device. Normally
the device is always sleeping to save the battery energy.

Over The Air (OTA) Firmware Update

The device support the Z-Wave firmware update via OTA.
Let the controller into the firmware update mode, and then press the
tamper key once to start the update.
After   finish   the   firmware   download,  

please   don't   remove   the

battery

, otherwise it will cause the firmware broken, and the device

will no function.
After the LED stop flash, it is recommended that the user power up the
device.  

Caution

:   After   remove   the   battery,   please   wait   about   30

seconds, and then re-install the battery.

Battery Installation

User need change the battery while the device is showing battery low
message.   Please   make   sure   to   replace   the   battery   with   a   1-minute
interval. Normally the device would flash the light right after replacing
it with a new battery.
The battery type is CR123A, 3.0V.

Open the front cover and do following steps:
1. Use a screwdriver to loosen the screw on bottom side. (step 1)
2. Slide up the front cover. (Step 2)

Change the battery

3. Slide down the front cover. (Step 3)
4. Lock the screw on bottom side. (Step 4)

5

Summary of Contents for PSP06

Page 1: ...veTM 700 series chip when your Z WaveTM network system is all made by Z WaveTM 700 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed speed up communication Specification Power 3VDC CR123A lithium battery Battery life 10 years RF distance...

Page 2: ...or mechanically crushing or cutting of a battery that can result in an explosion leaving a battery in an extremely high temperature surrounding environment that can result in an explosion or the leakage of flammable liquid or gas a battery subjected to extremely low air pressure that may result in an explosion or the leakage of flammable liquid or gas The marking information is located at the bott...

Page 3: ...operable 1 Pressing tamper key four times within 1 5 seconds and do not release the tamper key in the 4th pressed and the LED will light ON 2 After 3 seconds the LED will turn OFF after that within 2 seconds release the tamper key If successful the LED will light ON one second Otherwise the LED will flash once 3 IDs are excluded and all settings will reset to factory default SmartStart 1 Product h...

Page 4: ...Report Both the 2 tamper keys are pressed over 5 seconds The device will into the alarm state In that state if any one of the tamper keys be released the device will unsolicited to send the report to the nodes in the group 1 Notification Report V8 Notification Type Home Security 0x07 Event Tampering Product covering removed 0x03 Timing Report Beside the event triggered could report message the dev...

Page 5: ...the firmware download please don t remove the battery otherwise it will cause the firmware broken and the device will no function After the LED stop flash it is recommended that the user power up the device Caution After remove the battery please wait about 30 seconds and then re install the battery Battery Installation User need change the battery while the device is showing battery low message P...

Page 6: ... 2 Let the controller associate with the device into the first group any light switch that intend to be turned on when the device trig please associate with the device into the second group 3 In the accessory pack There is double coated tape you can use a double coated type for the test at the beginning The right way for double coated type installation is to stick it to the position of the back th...

Page 7: ...hat the logical path of an intruder would cut across the fan pattern rather than directly towards the detector Z Wave Configuration Settings Notice All of the configuration the data size is 1 All of the configuration after the remove the setting still keep don t reset to factory default Unless the user execute the RESET procedure The reserve bit or not supported bit is allowed any value but no eff...

Page 8: ...ns the hight sensitivity 2 means the lowest sensitivity Z Wave Supported Command Class Command Class Version Required Security Class Z Wave Plus Info 2 None Security 1 None Security 2 1 None Supervision 1 None Transport Service 2 None Association 2 Highest granted Security Class Association Group Information 3 Highest granted Security Class Device Reset Locally 1 Highest granted Security Class Fir...

Page 9: ...uarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or televi sion reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and r...

Reviews: