Philio Technology Corporation PSP06 Manual Download Page 3

Add to/Remove from Z-Wave

TM

 Network

There   are   two   tamper   keys   in   the   device,   one   is   in   the   back   side,
another is in the front side.  Both of them  can add, remove, reset or
association from Z-Wave

TM

 network.

In the first time, add the device into the Z-Wave

TM

 network.  First, 

make sure the primary controller is in the add mode. And then power 
on the device, just take out the insulation Mylar in the back side of the 
device. The device will auto start the SmartStart Include mode.

Notice

: Including a node ID allocated by Z-Wave

TM

 Controller means 

Add

” or “

Inclusion

”.  Excluding a node ID allocated by Z-Wave

TM

  

Controller means “

Remove

” or “

Exclusion

”.

Function

Description

Add

1. Have Z-Wave

TM

 Controller entered inclusion mode.

2. Pressing the tamper key three times within 1.5 

seconds to enter the inclusion mode.

3. After add successful, the LED will light ON 1 

second.

Remove

1. Have Z-Wave

TM

 Controller entered exclusion mode.

2. Pressing tamper key three times within 1.5 seconds

to enter the exclusion mode.

3. Node ID has been excluded.

Reset

Notice: Use this procedure only in the event 
that the primary controller is lost or 
otherwise inoperable.

1. Pressing tamper key four times within 1.5 seconds 

and do not release the tamper key in the 4

th

 

pressed, and the LED will light ON.

2. After 3 seconds the LED will turn OFF, after that 

within 2 seconds, release the tamper key. If 
successful, the LED will light ON one second. 

Otherwise, the LED will flash once.

3. IDs are excluded and all settings will reset to 

factory default.

SmartStart

1. Product has a DSK string, you can key in first five 

digit to increment SmartStart process, or you can 
scan QR code.

Ex : mydsk

10209-46687-52248-13629-04783-07465-15776-56519

2. SmartStart enabled products can be added into a Z-

Wave network by scanning the Z-Wave QR Code 
present on the product providing SmartStart 
inclusion. No further action is required and the 
SmartStart product will be added automatically 
within 10 minutes of minutes On in the network 
vicinity.

notice1:The QR code can be found on the device 

PSP06 or on the box.

Association

This machine provides two groups of nodes. 
Group 1 can set 1 Nodes.
Group 2 can set 5 Nodes.

Group 1 is called Lifeline the device will report :
1.Notification report
2.Device Reset Locally Notification
3.Battery Report
4.Indicator Report

Group 2 is called Basic set the device will report :
1.Basic Set

Failed or success in add/remove the node ID can be viewed 
from Z-Wave

TM

 Controller.

3

Summary of Contents for PSP06

Page 1: ...veTM 700 series chip when your Z WaveTM network system is all made by Z WaveTM 700 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed speed up communication Specification Power 3VDC CR123A lithium battery Battery life 10 years RF distance...

Page 2: ...or mechanically crushing or cutting of a battery that can result in an explosion leaving a battery in an extremely high temperature surrounding environment that can result in an explosion or the leakage of flammable liquid or gas a battery subjected to extremely low air pressure that may result in an explosion or the leakage of flammable liquid or gas The marking information is located at the bott...

Page 3: ...operable 1 Pressing tamper key four times within 1 5 seconds and do not release the tamper key in the 4th pressed and the LED will light ON 2 After 3 seconds the LED will turn OFF after that within 2 seconds release the tamper key If successful the LED will light ON one second Otherwise the LED will flash once 3 IDs are excluded and all settings will reset to factory default SmartStart 1 Product h...

Page 4: ...Report Both the 2 tamper keys are pressed over 5 seconds The device will into the alarm state In that state if any one of the tamper keys be released the device will unsolicited to send the report to the nodes in the group 1 Notification Report V8 Notification Type Home Security 0x07 Event Tampering Product covering removed 0x03 Timing Report Beside the event triggered could report message the dev...

Page 5: ...the firmware download please don t remove the battery otherwise it will cause the firmware broken and the device will no function After the LED stop flash it is recommended that the user power up the device Caution After remove the battery please wait about 30 seconds and then re install the battery Battery Installation User need change the battery while the device is showing battery low message P...

Page 6: ... 2 Let the controller associate with the device into the first group any light switch that intend to be turned on when the device trig please associate with the device into the second group 3 In the accessory pack There is double coated tape you can use a double coated type for the test at the beginning The right way for double coated type installation is to stick it to the position of the back th...

Page 7: ...hat the logical path of an intruder would cut across the fan pattern rather than directly towards the detector Z Wave Configuration Settings Notice All of the configuration the data size is 1 All of the configuration after the remove the setting still keep don t reset to factory default Unless the user execute the RESET procedure The reserve bit or not supported bit is allowed any value but no eff...

Page 8: ...ns the hight sensitivity 2 means the lowest sensitivity Z Wave Supported Command Class Command Class Version Required Security Class Z Wave Plus Info 2 None Security 1 None Security 2 1 None Supervision 1 None Transport Service 2 None Association 2 Highest granted Security Class Association Group Information 3 Highest granted Security Class Device Reset Locally 1 Highest granted Security Class Fir...

Page 9: ...uarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or televi sion reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and r...

Reviews: