![Philio Technology Corporation PSM11 Manual Download Page 6](http://html.mh-extra.com/html/philio-technology-corporation/psm11/psm11_manual_1537990006.webp)
Z-Wave Configuration Settings
Notice:
*
All of the configuration, the data size is 1.
*
All of the configuration after the remove the setting still keep, don't
reset to factory default. Unless the user execute the “RESET”
procedure.
*
The reserve bit or not supported bit is allowed any value, but no
effect.
NO.
Name
Def. Valid
Description
1 Auto Report
Tick Interval
60
1 ~
0xFF
The interval time for auto report
each tick.(unit:minute)
2 Auto Report
Battery Time
6
1 ~
0xFF
The interval time for auto report the
battery level.
3 Customer
Function
3
All
Operation mode. Using bit to
control.
1
Bit0
: Disable auto report battery
function.
0 : Disable / 1 : Enable
1
Bit1
: Disable auto report
door/window function.
0 : Disable / 1 : Enable
0
Bit2
: Reserve.
0
Bit3
: Reserve.
0
Bit4
: Reserve.
0
Bit5
: Reserve.
0
Bit6
: Reserve.
0
Bit7
: Reserve.
4 Basic ON
0xFF
All
Setting the BASIC command value.
6