Philio Technology Corporation PSM11 Manual Download Page 3

Add to/Remove from Z-Wave

TM

 Network

There are one tamper keys in the back side of the device, It can add,

remove, reset or association from the Z-Wave

TM

 network.

In the first time, add the device into the Z-Wave

TM

 network.  First, 

make sure the primary controller is in the add mode. And then power 

on the device, just take out the insulation Mylar in the back side of the 

device. The device will auto start the SmartStart Include mode.

Notice

: Including a node ID allocated by Z-Wave

TM

 Controller means 

Add

” or “

Inclusion

”.  Excluding a node ID allocated by Z-Wave

TM

  

Controller means “

Remove

” or “

Exclusion

”.

Function

Description

Add

1. Have Z-Wave

TM

 Controller entered inclusion mode.

2. Pressing the tamper key three times within 1.5 

seconds to enter the inclusion mode.

3. After add successful, the LED will light ON 1 

second.

Remove

1. Have Z-Wave

TM

 Controller entered exclusion mode.

2. Pressing tamper key three times within 1.5 seconds

to enter the exclusion mode.

3. Node ID has been excluded.

Reset

Notice: Use this procedure only in the event 

that the primary controller is lost or 

otherwise inoperable.

1. Pressing tamper key four times within 1.5 seconds 

and do not release the tamper key in the 4

th

 

pressed, and the LED will light ON.

2. After 3 seconds the LED will turn OFF, after that 

within 2 seconds, release the tamper key. If 

successful, the LED will light ON one second. 

Otherwise, the LED will flash once.

3. IDs are excluded and all settings will reset to 

factory default.

SmartStart

1. Product has a DSK string, you can key in first five 

digit to increment SmartStart process, or you can 

scan QR code.

Ex : mydsk

10209-46687-52248-13629-04783-07465-15776-56519

2. SmartStart enabled products can be added into a Z-

Wave network by scanning the Z-Wave QR Code 
present on the product providing SmartStart 
inclusion. No further action is required and the 
SmartStart product will be added automatically 
within 10 minutes of minutes On in the network 
vicinity.

notice1:The QR code can be found on the device 

PSM11 or on the box.

Association

This machine provides two groups of nodes. 

Group 1 can set 1 Nodes.

Group 2 can set 5 Nodes.

Group 1 is called Lifeline the device will report :

1.Notification report

2.Device Reset Locally Notification

3.Battery Report

4.Indicator Report

Group 2 is called Basic set the device will report :

1.Basic Set

Failed or success in add/remove the node ID can be viewed 

from Z-Wave

TM

 Controller.

3

Summary of Contents for PSM11

Page 1: ...r Z WaveTM network system is all made by Z WaveTM 700 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed speed up communication Specification Power 3VDC CR123A lithium battery Battery life 20 years RF distance Min 40M indoor 100M outdoor ...

Page 2: ...hot oven or mechanically crushing or cutting of a battery that can result in an explosion leaving a battery in an extremely high temperature surrounding environment that can result in an explosion or the leakage of flammable liquid or gas a battery subjected to extremely low air pressure that may result in an explosion or the leakage of flammable liquid or gas The marking information is located at...

Page 3: ...amper key four times within 1 5 seconds and do not release the tamper key in the 4th pressed and the LED will light ON 2 After 3 seconds the LED will turn OFF after that within 2 seconds release the tamper key If successful the LED will light ON one second Otherwise the LED will flash once 3 IDs are excluded and all settings will reset to factory default SmartStart 1 Product has a DSK string you c...

Page 4: ...y pressed over 5 seconds The device will into the alarm state In that state if the tamper key be released the device will unsolicited to send the report to the nodes in the group 1 Notification Report V8 Notification Type Home Security 0x07 Event Tampering Product covering removed 0x03 Timing Report Beside the event triggered could report message the device also support the timing unsolicited repo...

Page 5: ... low battery message users should replace the battery The battery type is CR123A 3 0V Installation In the first time add the device into the Z WaveTM network First make sure the primary controller is in the inclusion mode And then power on the device just take out the insulation Mylar in the back side of the device The device will auto start the SmartStart Include mode You will see the LED light O...

Page 6: ...ion 1 Auto Report Tick Interval 60 1 0xFF The interval time for auto report each tick unit minute 2 Auto Report Battery Time 6 1 0xFF The interval time for auto report the battery level 3 Customer Function 3 All Operation mode Using bit to control 1 Bit0 Disable auto report battery function 0 Disable 1 Enable 1 Bit1 Disable auto report door window function 0 Disable 1 Enable 0 Bit2 Reserve 0 Bit3 ...

Page 7: ...ity Class Configuration 4 Highest granted Security Class Notification 8 Highest granted Security Class Battery 1 Highest granted Security Class Disposal This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustai...

Page 8: ...let on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including inter ference that may cause undesired oper...