2.
Press the include button of the PAT12
three times within
3
seconds to enter
inclusion mode.
If the learning code is successful, the
LED light will flash slowly.
Remove (Exclusion) 1.
Put your Z-Wave controller into
exclusion mode by following the
instructions provided by the
controller manufacturer.
2.
Press the include button of the PAT12
three times within
3
seconds to enter
exclusion mode.
3. Node ID has been excluded.
LED light will flash for 30
seconds.
Reset
1.
Press the include button of the PAT12
three times within
3
seconds to enter
inclusion mode.
Use this procedure only in
the event that the primary
controller is lost or otherwise in-
operable.
2.
Within 1 second, again press the
include button of the PAT12 for 5
seconds.
3.
IDs will get excluded.
SmartStart
1. Product has a DSK string, you can key
in the first five digits to begin with the
smart start process, or you can scan
QR code.
Ex: mydsk
10209-46687-52248-13629-04783-07465-
15776-56519
2. SmartStart enabled products can be
added into a Z-Wave network by
scanning the Z-Wave QR Code
present on the product providing. No
further action is required and the
SmartStart product will be added
automatically within 10 minutes of the
network vicinity.
Association
This machine provides a group of nodes.
Each group can set 5 Nodes.
Group 1: Used for returned events.
Report type:
1.Notification report
2.Sensor multilevel report
3.Reset report
Adding a node ID allocated by Z-Wave Controller means inclusion. Removing a node
ID allocated by Z-Wave Controller means exclusion.
Failed or success in including/excluding the node ID can be viewed from the Z-Wave
Controller.
LED Indication
To distinguish what mode the switch is in, view the LED light description for
identification.
State Type
LED Indication
No node ID
Under normal operation, when the Switch has not been allocated a node ID, the
LED light will flash on and off alternately at 30 second intervals. By pressing
On/Off button, the light will stop flashing temporarily.
Learning
When the PAT12 is in learning mode, if the learning code is successful, the LED
light will flash slowly.
Programming
2. Z-Wave’s Configuration
Configuration
Parameter
Function
Size
(Byte)
Value
Default
Description
1
Fixed timer for re-
port CO2 concen-
tration
2
0-127
60
Units of 1 minute.
0 means turn off the report
2
Concentration
change report
1
0-100
10
Units of 1 %.
0 means turn off the report
3
Baseline level 1
1
0-50
0
Units of 100 ppm.
0 means turn off the report
3
Summary of Contents for PAT12-A
Page 1: ......