to let relay back to the correspond state. Manual switch S2 is disabled in this
mode.
3-10-2 Pulse mode: this mode is suitable for the toggle type wall switch to swap the
state of Relay1.
3-10-3 Edge-Toggle mode: this mode is suitable for the normal bi-stable switch,
whenever change the state of the wall switch will also swap the state of
Relay1.
3-11 Manual Switch Report mode :
Whenever PAN03 is manually switch on or off, it will send BINARY_SWITCH_
REPORT to the node of group1. The default setting is Enable the function.
3-12 Watt differential report mode :
3-12-1 Disable : The function of Watt differential report will be disabled.
3-12-2 5% : When the differential value of Watt is over 5%, PAN03 will send
a meter report to the associated group.
3-12-3 10% : When the differential value of Watt is over 10%, PAN03 will
send a meter report to the associated group.
3-12-4 15% : When the differential value of Watt is over 15%, PAN03 will
send a meter report to the associated group.
3-12-5 20% : When the differential value of Watt is over 20%, PAN03 will
send a meter report to the associated group.
4. Protection Command Classes
PAN03 supports Protection Command Class version 2, it can protect the switch
against unintentionally control by e.g. a child. And it can also protect the switch from
being turned off by setting it in “No RF Control” state.
After being set to “Protection by sequence” state, any intentional pressing of On/Off
button should be hold longer than 1 second, or the switch state will not change.
However, the operation of learn function does not change, because learning will not
be protected.
5. Firmware update over the air (OTA)
PAN03 is based on 500 series SoC and supports Firmware Update Command Class,
it can receives the updated firmware image sent by controller via the Z-wave RF
media. It is a helpful and convenient way to improve some function if needed.
6. Command Classes
The Switch supports Command Classes including…
* COMMAND_CLASS_ZWAVEPLUS_INFO
* COMMAND_CLASS_VERSION
* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
* COMMAND_CLASS_SECURITY
* COMMAND_CLASS_DEVICE_RESET_LOCALLY
* COMMAND_CLASS_ASSOCIATION_V2
* COMMAND_CLASS_ASSOCIATION_GRP_INFO
* COMMAND_CLASS_POWERLEVEL
* COMMAND_CLASS_SWITCH_BINARY
* COMMAND_CLASS_BASIC
* COMMAND_CLASS_SWITCH_ALL
* COMMAND_CLASS_METER_V3
* COMMAND_CLASS_CONFIGURATION
* COMMAND_CLASS_ALARM
* COMMAND_CLASS_PROTECTION
* COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
Warning:
1. Plug out to disconnect from power supply; Do not plug in line.
2. Do not exceed the max rating