Philio Technology Corporation PAN03 Manual Download Page 7

 

32767s

 

9

 

RF off 
command mode

 

1

 

0-3

 

 

0

 

0 : Switch off

 

1 : Ignore

 

2 : Switch toggle

 

3 : Switch on

 

10

 

Edge or Pulse

 

mode or

 

Edge-Toggle 

mode

 

1

 

1-3

 

 

1

 

1

Edge mode

 

2

Pulse mode

 

3

Edge-Toggle mode

 

11

 

Manual  Switch 

Report mode

 

1

 

0-1

 

 

1

 

0 : Disable

 

1 : Enable

 

14

 

Watt differential

 

report mode

 

1

 

0-4

 

 

1

 

0 : Disable

 

1 : 5%

 

2 : 10%

 

3 : 15%

 

4 : 20%

 

 

3-1

 Watt 

Meter Report Period:

 

    If the setting is configured for 1hour (set value =720), the PAN03 will report its 

instant power consumption every 1 hour to Group1 node.    The maximum interval 
to report its instant power consumption is 45 hours (5s*32767/3600=45hr).    If the 
setting value is 0, the auto report function of meter Watt will be disabled.

 

 

3-2 KWH Meter Report Period:

 

      If  the  setting  is  configured  for  1hour  (set  value  =6),  the  PAN03  will  report  its 

Accumulated  Power  Consumption  (KW/h)  every  1  hour  to  Group1  node.    The 
maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 
days  (10min*32767/1440=227.55  days).  If  the  setting  value  is  0,  the  auto  report 
function of meter KW/h will be disabled.

 

 

3-3 Threshold of current for Load Caution

 

This  is  a  warning  when  the  current  of  load  over  the  preset  threshold  value,  if  the 

setting value is 1100, when the load current of Relay1 over this value, PAN03 will 
send current meter report to warn the Group1 node, the Range of the setting value 
is from 10 to 1100, and the default value is 1100.

 

3-4 Threshold of KWh for Load Caution

 

This  is  a  warning  when  the  KWh  of  load  over  the  preset  threshold  value,  if  the 
setting value is 10000, when the Accumulated Power Consumption of Relay1 over 
this value, PAN03 will send KWH meter report to warn the Group1 node, minimum 
value is 1KWh and default value is 10000 kWh.

 

3-5 Restore switch state mode:

 

  Whenever the AC power return from lost, PAN03 will restore the switch state which 

could be SWITCH OFF

LAST SWITCH STATE

SWITCH ON. The default setting 

is LAST SWITCH STATE.

 

3-6 Manual On/Off Mode:

 

The On/Off function of S1

S2 and learn switch can be disabled or enabled by this 

parameter, default value is Enable. But the learning operation won’t be affected.   
When manual On/Off function is disabled, the RF command can only switch On 
but not Off. This is useful function for keeping the device in switch on state.

 

3-7 LED indication mode:

 

  3-7-1 Show Switch State

When switch is on, LED is on. When switch is off, LED is 

off. The default setting is Show Switch State.

 

  3-7-2 Show Night mode

When switch is on, LED is off. When switch is off, LED is 

on.

 

  3-7-3 One Flash mode

When the state of switch changes, LED will be on only one 

second, then LED keeps off.

 

3-8 Auto off timer

 

  Whenever PAN03 switches to on, the auto off timer begin to count down. After the 

timer decrease to zero, it will switch to off automatically. However if Auto off timer 
is set as 0, the auto off function will be disabled. The default setting is 0.

 

3-9 RF off command mode

 

  Whenever a switch off command, BASIC_SET

BINARY_SWITCH_SET

 

SWITCH_ALL_OFF, is received, it could be interpreted as 4 variety of commands. 

 

3-9-1 Switch Off

It switches to OFF state. The default setting is Switch Off.

 

3-9-2 Ignore

The switch off command will be ignored.

 

3-9-3 Switch Toggle

It switches to the inverse of current state.

 

3-9-4 Switch On

It switches to ON state.

 

3-10 Edge mode

Pulse mode and Edge-Toggle mode

 

Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle

 

mode, default value is Edge mode. 

 

3-10-1 Edge mode: this mode is suitable for the bi-stable wall switch that has indicator 

point on the switch, and the same position correspond to same state of relay1. 

If the PAN03 relay change the state because of receiving Z-Wave RF 

command, it may need two times of change (switch on to off or switch off to on) 

Summary of Contents for PAN03

Page 1: ...ill reset its overload condition to normal status Safety Precautions and Installation Avoid installing the unit in storming or raining weather Be sure to isolate or switch off power source before installing or maintenance Do ensure that the power supply circuit protected by a 16A circuit breaker or suitable equivalent fuse IMPORTANT Installation must be performed by skilled technicians who are inf...

Page 2: ...y out association 2 Wait for a while to re try LED keep flashing but cannot control Overload occurs Remove the load attached or check max load cannot exceed 12 0A Resistive load Installation Fig 1 PAN03 Assembling For Instruction to http www philio tech com DANGER Danger of electrocution All works on the device may be performed only by a qualified and licensed electrician Observe national regulati...

Page 3: ...ng of the device when already installed the external switch can be used for inclusion or exclusion for 3 minutes after power up 2 Pressing On Off button three times within 2 seconds will enter exclusion mode Node ID has been excluded 0 5s On 0 5s Off Enter auto inclusion Reset 1 Pressing On Off button three times within 2 seconds will enter inclusion mode Use this procedure only in the event that ...

Page 4: ...lowing commands from a Z Wave Controller the Switch will report its On Off state to the node asked Basic Get Command Command Class Basic Basic Get Basic Report Command Report OFF Command Class Basic Basic Report Value 0 0x00 Report ON Command Class Basic Basic Report Value 255 0xFF Binary Switch Get Command Command Class Switch Binary Switch Binary Get Binary Switch Report Command Report OFF Comma...

Page 5: ...Controller after receive the Meter Get Command from Z Wave Controller 2 2 1 Instant Power Consumption Watt of Switch When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x02 W Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 1 Scale 0x02 Size 4 Meter Value W Example Mete...

Page 6: ... receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x06 PF Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x06 Size 1 Bytes Meter Value PF Example Scale 0x06 PF Precision 2 Size 1 1 Byte of PF Meter Value 1 0x63 PF Load power factor PF Meter Value 1 0 99 3 Z Wave ...

Page 7: ... from lost PAN03 will restore the switch state which could be SWITCH OFF LAST SWITCH STATE SWITCH ON The default setting is LAST SWITCH STATE 3 6 Manual On Off Mode The On Off function of S1 S2 and learn switch can be disabled or enabled by this parameter default value is Enable But the learning operation won t be affected When manual On Off function is disabled the RF command can only switch On b...

Page 8: ...ion Command Class version 2 it can protect the switch against unintentionally control by e g a child And it can also protect the switch from being turned off by setting it in No RF Control state After being set to Protection by sequence state any intentional pressing of On Off button should be hold longer than 1 second or the switch state will not change However the operation of learn function doe...

Page 9: ...f and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with P...

Reviews: