Introduction

 

This  plug-in  ON/OFF  switch  PAN03  is  a  security  enabled  wireless  switch,  based  on 
Z-Wave  Plus  technology.  Z-Wave  Plus

TM

  enabled  devices  displaying  the  Z-Wave 

Plus

TM

 logo can also be used with it regardless of the manufacturer, and can also be 

used in other manufacturer’s Z-Wave

TM

 enabled networks. Remote On/Off control of 

the  connected  load  is  possible  with  other  manufacturer’s  wireless  Controller.  Each 
switch  is  designed  to  act  as  a  repeater.  Repeaters  will  re-transmit  the  RF  signal  to 
ensure  that  the  signal  is  received  by  its  intended  destination  by  routing  the  signal 
around obstacles and radio dead spots. Because PAN03 supports Security Command 
Class, it can learn with  Secured controller. Its functionality and supported command 
classes is identical when included as a secure and non-secure device.

 

 
This plug-in ON/OFF switch is able to detect instance wattage and overload current 
(12A with resistive load) of connected lights or appliances. When detecting overload 
state, the Switch will be disabled and its On/Off button will be lockout of which LED 
will flash quickly.    However, unplug and re-connect the switch will reset its overload 
condition to normal status. 

 

Safety Precautions and Installation 

 

 

Avoid installing the unit in storming or raining weather. 

 

 

Be sure to isolate or switch off power source before installing or maintenance. 

 

 

Do ensure that the power supply circuit protected by a 16A circuit breaker or 

suitable equivalent fuse. 

 

 

IMPORTANT

 

 

Installation must be performed by skilled technicians who are informed about the 

standards and technical requirements of the appliance and its proper 

installation. 

 

 

Check your local codes as they apply to your situation. If the house wiring is of 

aluminum, consult with an electrician about proper wiring methods. 

 

Before proceeding with the installation, TURN OFF THE POWER TO THE LIGHTING 

CIRCUIT AT THE CIRCUIT BREAKER OR FUSE BOX TO AVOID ELECTRICAL 

SHOCK.

 

 

Specification

 

 

Operating Voltage

 

100 - 240VAC 50Hz/60Hz 11A

 

Maximum Load

 

11A (Resistive load)

 

Range

 

Minimum 40m indoor, 100m outdoor line of sight

 

Operating Temperature

 

0°C to 40°C

 

Humidity

 

Up to 85% max.

 

Storage Temperature

 

-20°C to 60°C

 

Location

 

Indoor use only

 

Frequency Range

 

PAN03-1: 868.40MHz; 869.85MHz(EU) /

 

PAN03-2: 908.40MHz; 916.00MHz(USA/Canada) / 

 

PAN03-3: 920.90 MHz, 921.70 MHz, 923.10 MHz (Taiwan)

 

PAN03-IL: 916.00MHz(Israel)

 

RF Power 

 

+5dBm 

 

OTA

 

support

 

FCC ID

 

RHHPAN03

 

Dimensions

 

47.5 x 39 x16 mm

 

Wire

 

0.75mm², 18AWG

 

** Specifications are subject to change and improvement without notice.       

 

Summary of Contents for PAN03

Page 1: ...ill reset its overload condition to normal status Safety Precautions and Installation Avoid installing the unit in storming or raining weather Be sure to isolate or switch off power source before installing or maintenance Do ensure that the power supply circuit protected by a 16A circuit breaker or suitable equivalent fuse IMPORTANT Installation must be performed by skilled technicians who are inf...

Page 2: ...y out association 2 Wait for a while to re try LED keep flashing but cannot control Overload occurs Remove the load attached or check max load cannot exceed 12 0A Resistive load Installation Fig 1 PAN03 Assembling For Instruction to http www philio tech com DANGER Danger of electrocution All works on the device may be performed only by a qualified and licensed electrician Observe national regulati...

Page 3: ...ng of the device when already installed the external switch can be used for inclusion or exclusion for 3 minutes after power up 2 Pressing On Off button three times within 2 seconds will enter exclusion mode Node ID has been excluded 0 5s On 0 5s Off Enter auto inclusion Reset 1 Pressing On Off button three times within 2 seconds will enter inclusion mode Use this procedure only in the event that ...

Page 4: ...lowing commands from a Z Wave Controller the Switch will report its On Off state to the node asked Basic Get Command Command Class Basic Basic Get Basic Report Command Report OFF Command Class Basic Basic Report Value 0 0x00 Report ON Command Class Basic Basic Report Value 255 0xFF Binary Switch Get Command Command Class Switch Binary Switch Binary Get Binary Switch Report Command Report OFF Comma...

Page 5: ...Controller after receive the Meter Get Command from Z Wave Controller 2 2 1 Instant Power Consumption Watt of Switch When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x02 W Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 1 Scale 0x02 Size 4 Meter Value W Example Mete...

Page 6: ... receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x06 PF Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x06 Size 1 Bytes Meter Value PF Example Scale 0x06 PF Precision 2 Size 1 1 Byte of PF Meter Value 1 0x63 PF Load power factor PF Meter Value 1 0 99 3 Z Wave ...

Page 7: ... from lost PAN03 will restore the switch state which could be SWITCH OFF LAST SWITCH STATE SWITCH ON The default setting is LAST SWITCH STATE 3 6 Manual On Off Mode The On Off function of S1 S2 and learn switch can be disabled or enabled by this parameter default value is Enable But the learning operation won t be affected When manual On Off function is disabled the RF command can only switch On b...

Page 8: ...ion Command Class version 2 it can protect the switch against unintentionally control by e g a child And it can also protect the switch from being turned off by setting it in No RF Control state After being set to Protection by sequence state any intentional pressing of On Off button should be hold longer than 1 second or the switch state will not change However the operation of learn function doe...

Page 9: ...f and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with P...

Reviews: