for the module as per data sheet. And Tmin: refer to the lowest ambient Temperature. 

 

The voltage is proportional to the number of series. In case of parallel connection please 

be sure to take proper measure (e.g. fuse for protection of module and cable form over 

current, and /or blocking diode for prevention of unbalanced strings voltage) to block 

the reverse current flow. The current may easily flow in a reverse direction. 

 

If more than 2 PV Modules or sting of Modules connected in parallel a PV Fuse with a 

rating    of 15A shall be used for both negative and positive side and in accordance with 

IEC 62446 & IEC60346 and their associated codes. 

 

Be careful! Always check the module label to confirm the actual rating of your product 

before making connections whether it is 1000Vdc or 1500Vdc. 

 

It is recommended to use a suitably rated isolator (DC switch) to interrupt the current flow 

before disconnecting the connectors. 

 

HANDLING SAFETY 

 

Do not cause an excessive load on the surface of PV module or twist the frame. The glass 

surface can easily break. 

 

Do not stand or step on the PV module. The glass surface of PV is slippery and that would 

cause microcracks in cells which affect the power generation. 

 

Do not hit or put excessive load on the glass or in the Backsheet, it is vulnerable. 

 

Do not hit the terminal box or do not pull the cables. The terminal box can crack and 

break. 

 

Never touch the terminal box or the end of output cables with bare hands when the PV 

module  is  irradiated.  Cover  the  surface  of  PV  module  with  clothes  or  other  suitable 

sufficiently opaque material to isolate the PV module from incident light and handle the 

wires with rubber-gloved hands to avoid electric   shock. 

 

To make positive electrical contact with the frame. The ground wire must be considered 

within the requirement of local and regulation at the site of installation. 

 

The ground wire cross-sectional area (4-14) mm

2

, the minimum size of ground wire (6-12) 

AWG  (solid  bare  copper)  per  Table  250.122  of  NEC  code.  Conductor  Type:  Copper 

Material-

Color of wire: Green color with yellow stripe. • Do not drill holes in the frame. It 

may compromise the frame strength and cause corrosion of the   frame. 

 

Do not scratch the insulation coating of the frame (except for grounding connection. it 

may cause corrosion of the frame or compromise the framework strength. 

Summary of Contents for PS-M60 Series

Page 1: ...Installation...

Page 2: ...ect PV Modules cables from direct sunlight 6 Do not strain junction box conductors 7 Do not touch any surface ofmodule 8 Do not place drop objects onto the PVmodule 9 Do not disassemble or attempt to...

Page 3: ...reserves the right to make changes to the product specifications or installation manual without prior notice GENERAL INFORMATION The installation of PV modules requires a great degree of skill and sho...

Page 4: ...s most likely to be damaged In the case of a brush type motor the coil is most likely to be damaged GERNERAL SAFETY Consult local codes and other applicable laws concerning required permits on regulat...

Page 5: ...a risk of frost damage when the frame is filled with water accumulation When sliding snow load has to be considered an appropriate measure has to be taken so that PV module frames on lower edge of PV...

Page 6: ...t stand or step on the PV module The glass surface of PV is slippery and that would cause microcracks in cells which affect the power generation Do not hit or put excessive load on the glass or in the...

Page 7: ...get hot There is a risk of burn or you may collapse because of electric shock Do not work under rain snow or windy conditions Use insulated tools Do not use wet tools Donotdroptoolsorhard objects onP...

Page 8: ...be exposed to direct sunlight after installation to prevent degradation of cables SITE SELECTION In most applications the PV modules should be installed in a location where there is no shading throug...

Page 9: ...he tilt angle of the PV module for the maintenance For the stand alone systems with a battery where the PV modules are attached to a permanent structure the tilt angle of the PV modules should be dete...

Page 10: ...Insulation for DC cables according to IEC712 7 60364 The frame grounding must consider the local requirements and regulations at the site of installation When grounding is required please refer to the...

Page 11: ...or electrical conductivity Such devices where supplied with the module and evaluated through the requirements in UL 61730 may be used for grounding connectionsin accordance with the instructions provi...

Page 12: ...modules clamps should not contact module s glass or deform module s frame 2 Make sure to avoid shadowing from using clamps 3 Make sure to avoid modifying module s frame 4 Use 4 clamps on the long sid...

Page 13: ...el of load Condition applies to most of the environmental conditions Use four mounting holes applies to harsher environmental conditions such as storm heavy snow etc use eight mounting holes Clamping...

Page 14: ...max are within 5 under STC conditions Irradiance of 1000W m2 Am 1 5 spectrum and ambient Temperature of 25C The operating Temperature range 40 C to 85 C under IEC standards 40 C to 90 C under UL 6173...

Page 15: ...contact access is anticipated modules qualified for safety through EN IEC 61730 1 and IEC 61730 2 within this application class are considered to meet the requirements for safety class II Fuses The m...

Page 16: ...mate conditions PS modules are designed and tested to withstand harsh conditions for more than 25 years In addition to the required IEC certification to meet European standards PS products have also b...

Page 17: ...ge at NMOT in Watt 274 281 225 230 244 252 196 204 274 280 225 230 Open Circuit Voltage Voc at NMOT v 45 6 46 68 37 37 38 8 44 5 44 35 36 4 37 43 45 95 47 43 38 96 39 20 Short Circuit Current Isc at N...

Reviews: