IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS FOR FUTURE USE

WHEN USING ELECTRICAL APPLIANCES, BASIC PRECAUTIONS SHOULD

ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,

AND INJURY TO PERSONS, INCLUDING THE FOLLOWING:

Read all instructions before using this heater. Failure to follow these important safety

instructions may cause fire, electric shock or damage. Following proper safety and

operating instructions is the responsibility of the owner.

1) Grounding (If necessary) - this heater is for use on 120 volts. DO NOT attempt to

modify the plug in any way or use adaptor to defeat the purpose of the grounding

feature.

2) This heater is hot when in use. To avoid burns, do not let skin come in direct

contact with hot surfaces. The grill directly in front of the heater outlet becomes hot

during heater operation.

3) Front of fireplace should remain not blocked while in use.

4) CAUTION: Extreme caution is necessary when any heater is used by or near

children or those with disabilities. Never leave the heater operating unattended.

5) Do not operate any heater with a damaged cord or plug or after the heater

malfunctions, has been dropped or damaged in any manner. Take heater to

authorized service facility for examination, electrical or mechanical adjustment or

repair.

6) Under no circumstance should this electric heater be modified. Parts having to be

removed for servicing must be replaced by a certified repair center prior to

operating this electric heater again.

7) Do not use outdoors or anywhere it can get wet. This heater is not intended for use

in bathrooms, laundry areas and similar indoor locations. Never locate heater in

bathrooms, laundry areas and similar indoor locations. Never locate this appliance

where it may fall into a bathtub or other water container.

8) Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or

similar coverings. Arrange cord away from traffic area and where it will not be

tripped over.

9) To disconnect heater, turn off all controls, then remove plug from outlet.

10)Connect to property grounded outlets only.

11)Do not insert or allow foreign objects to enter any ventilation or exhaust opening as

this may cause an electric shock or fire, or damage the heater.

12)To prevent a possible fire, do not block air intakes or exhaust in any manner. Do

not use on soft surfaces, like a bed, where openings may become blocked.

13)CAUTION: A heater has hot and arcing or sparking parts inside. Do not use it in

areas where gasoline, propane, paint, or flammable liquids are used or stored or

where the unit will be exposed to flammable vapors. The heater should not be

Summary of Contents for AH-FP-28FC

Page 1: ...REPLACE HEATER Model AH FP 28FC Insert No NDF 65NB ATTENTION 1 Find a location for the electric heater that is protected from direct sunlight 2 Do not plug the electric heater into the power outlet be...

Page 2: ...acility for examination electrical or mechanical adjustment or repair 6 Under no circumstance should this electric heater be modified Parts having to be removed for servicing must be replaced by a cer...

Page 3: ...forming any cleaning maintenance or relocation of the heater 19 For off season storage keep in a dry place NOTE Procedures and techniques that are considered important enough to emphasize CAUTION Proc...

Page 4: ...60 min 44 lb 44lb Weight Limitation Evenly...

Page 5: ...Parts list TOOL REQUIRED PHILLIPS HEAD SCREWDRIVER...

Page 6: ...panels are assembled Step 1 Attach all PLASTIC CONNECTOR X to the PANELS H K F E G J and C as shown in Fig A 2 screws for each PLASTIC CONNECTOR Attach the LEFT UPPER SIDE PANEL H to the LEFT LOWER S...

Page 7: ...the RIGHT FRONT PANEL E using 1 KD SCREW See Fig B Fig B Step 3 Attach the LEFT and RIGHT SIDE PANELS H K F E G J and C to the BASE B using 4 KD SCREWS 2 screws for each side See Fig C Attach the 2 C...

Page 8: ...ion of 2 FRONT PANELS E and F and attach with 2 Large KD SCREWS P 1 screw for each side See Fig D Fig D Step 5 Place the UPPER FRONT PANEL C in between the upper section of 2 CONNECTORS S and attach w...

Page 9: ...all the TOP PANEL A to the unit as shown and attach with 3 KD SCREWS See Fig F Fig F Step 7 Tighten all KD SCREWS Step 8 Attach the LEGS Q to the INSERT with 8 LEG SCREWS R 4 screw for each side See F...

Page 10: ...accessory The use of wall anchor safety cable is highly recommended in order to reduce the risk of the fireplace being tipped over accidentally WARNING This cable may reduce possible risk of injury if...

Page 11: ...ctions The controls are located behind the grill below front glass and can be accessed by pulling the grill up from the top forward and down O I Press this button for main power and flame effect The i...

Page 12: ...trol knob to lowest setting and allow the heater to cool down before press the O I switch to off position Maintenance WARNING Completely disconnect power before attempting any maintenance or cleaning...

Page 13: ...cooled before attempting any cleaning Cleaning Glass Panel Remove dust with clean dry cloth Remove fingerprints and other marks from glass door by using a clean damp cloth Do not use abrasive cleaners...

Reviews: