Phenix Technologies VMS-2 Manual Download Page 5

1-2 

 

TECHNICAL SPECIFICATIONS 

 
 

Model: 

 

 

 

 

VMS-2 Portable Power Supply 

 

 

Input: 

 

 

 

 

220/240 Volts, 25 Amps, 60 Hz, Single Phase  

 

 

Output: 

 

 

 

 

0-240VAC; 25AAC MAX through Multilamm jacks (Will not reach 240VAC with the 
220VAC input. Output will be 0-220VAC)  

 

0-300VDC; 10ADC MAX through binding posts 

 

 

Instrumentation: 

 

 

 

 

AC Meters: 

 

Digital Voltmeter, 3 ½ digit resolution 

 

Scale:  0-300VAC.  Accuracy:  

±

 0.4% FS 

±

 2 counts 

 

 

 

Digital Ammeter, 3 ½ digit resolution 

 

Scale:  0-50AAC.  Accuracy:  

±

0.15% FS 

±

 6 counts 

 

 

 

 

 

DC Meters 

 

Digital Voltmeter, 3 ½ digit resolution 

 

Scale:  0-600VDC.  Accuracy:  

±

 0.1% FS 

±

 1 count 

 

 

 

Digital Ammeter, 3 ½ digit resolution 

 

Scale:  0-20ADC.  Accuracy:  

±

 0.1% FS 

±

 1 count 

 

 

 

 

Features: 

 

 

 

 

Main power circuit breaker with indicator lamp 

 

Independent overloads for both outputs: AC – overload breaker; DC – output fuse 

 

Output via Multilamm jacks (AC) and binding posts (DC) 

 

Simultaneous digital readouts of both RMS Voltage and Current in both AC & DC 

 

Two copies of instruction manual, parts list, and schematics 

 

 

 

 

Size: 
          19”L x 18”W x 10”H;  65 lbs. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for VMS-2

Page 1: ...PORTABLE POWER SUPPLY MODEL NUMBER VMS 2 VERSION 2 2 AR 9 17 2013...

Page 2: ...NGER INTRODUCTION AND TECHNICAL SPECIFICATIONS 1 CONTROL AND METERING DESCRIPTION 2 OPERATION AND CALIBRATION 3 CIRCUIT DIAGRAM SYMBOLS 4 ELECTRICAL DRAWINGS 5 RECOMMENDED SPARE PARTS 6 PARTS ORDERING...

Page 3: ...ipment have been listed below for your reference Become familiar with your instrument before performing an actual test Know your work area check that all circuits are de energized and locked out Never...

Page 4: ...operational voltage or current levels of various electro mechanical devices Both the voltage and current output levels can be simultaneously read and monitored with the highly accurate onboard meters...

Page 5: ...tal Ammeter 3 digit resolution Scale 0 50AAC Accuracy 0 15 FS 6 counts DC Meters Digital Voltmeter 3 digit resolution Scale 0 600VDC Accuracy 0 1 FS 1 count Digital Ammeter 3 digit resolution Scale 0...

Page 6: ...igital Ammeter Provides continuous display of AC output current in Amps 5 DC Digital Voltmeter Provides continuous display of DC output voltage in Volts 6 DC Digital Ammeter Provides continuous displa...

Page 7: ...2 2 Figure 1 VMS 2 Front Panel TECHNOLOGIES Accident Maryland USA PHENIX R...

Page 8: ...tilamm jacks or the binding posts depending on whether AC or DC will be used and hook up the component to be tested with the leads provided Operation 5 Turn on main circuit breaker switch to power on...

Page 9: ...or all normal indoor operations In the rare case that any meter needs calibration adjustments the procedure for doing so should be performed by qualified technical personnel such as the Phenix Technol...

Page 10: ...4 1...

Page 11: ...5 1 ELECTRICAL DIAGRAMS Drawing Number Description 1 9907010 VMS 2 Electrical Schematic...

Page 12: ......

Page 13: ...1 Fuse 5 1603503 KTK 10 Fuse 1 1423265 Neon Lamp Green 2 N A Output lead wires 1 1356212 Multilamm Plug Black 1 1356213 Multilamm Plug Red 4 1353042 Gator Clip 20 Amp 2 1353041 Gator Clip Boot Black...

Page 14: ...g parts to include the serial number of the unit as well as the part number of the replacement part When your purchase order is received at our office a representative of Phenix Technologies will cont...

Page 15: ...for Return Cause of Defect If Phenix Technologies Inc deems return of the part appropriate it will then issue an Authorization for Return If return is not deemed advisable other inspection arrangement...