GENERAL SAFETY PRECAUTIONS 

 

 

 

  HIGH VOLTAGE 

 

This equipment is capable of providing POTENTIALLY LETHAL VOLTAGES! 
Improper operation or test practices may result in injury or death to the 
operator or surrounding personnel.

 

 

The operation of High Voltage test equipment should only be performed by personnel 
familiar with HIGH VOLTAGE testing and safety procedures. The operator of this 
equipment must be aware of all hazards associated with High Voltage testing. The 
operator is responsible for himself and others in close proximity of the testing area.   
 
Some General Safety Practices for working with High Voltage Test Equipment have been 
listed below for your reference. 
 

 

Become familiar with your instrument before performing an actual test 

 

Know your work area, check that all circuits are de-energized and locked out. 

 

Never work alone; always work with another qualified worker. 

 

Mark off entire work area with barriers and warning tape. 

 

Make all personnel aware of your testing activities. 

 

Be aware of dangerous conditions that may arise from energizing a test specimen. 

 

Never modify test equipment, modifications to equipment could introduce an 
unknown hazard or hinder a designed-in safety feature. 

 

DO NOT operate damaged equipment. Remove power, and do not use the 
equipment until safe operation can be verified by service-trained personnel. 

 

Phenix Technologies, Inc. assumes no liability for unsafe or improper use of test equipment.  
 

CAUTION

!

Summary of Contents for VMS-2

Page 1: ...PORTABLE POWER SUPPLY MODEL NUMBER VMS 2 VERSION 2 2 AR 9 17 2013...

Page 2: ...NGER INTRODUCTION AND TECHNICAL SPECIFICATIONS 1 CONTROL AND METERING DESCRIPTION 2 OPERATION AND CALIBRATION 3 CIRCUIT DIAGRAM SYMBOLS 4 ELECTRICAL DRAWINGS 5 RECOMMENDED SPARE PARTS 6 PARTS ORDERING...

Page 3: ...ipment have been listed below for your reference Become familiar with your instrument before performing an actual test Know your work area check that all circuits are de energized and locked out Never...

Page 4: ...operational voltage or current levels of various electro mechanical devices Both the voltage and current output levels can be simultaneously read and monitored with the highly accurate onboard meters...

Page 5: ...tal Ammeter 3 digit resolution Scale 0 50AAC Accuracy 0 15 FS 6 counts DC Meters Digital Voltmeter 3 digit resolution Scale 0 600VDC Accuracy 0 1 FS 1 count Digital Ammeter 3 digit resolution Scale 0...

Page 6: ...igital Ammeter Provides continuous display of AC output current in Amps 5 DC Digital Voltmeter Provides continuous display of DC output voltage in Volts 6 DC Digital Ammeter Provides continuous displa...

Page 7: ...2 2 Figure 1 VMS 2 Front Panel TECHNOLOGIES Accident Maryland USA PHENIX R...

Page 8: ...tilamm jacks or the binding posts depending on whether AC or DC will be used and hook up the component to be tested with the leads provided Operation 5 Turn on main circuit breaker switch to power on...

Page 9: ...or all normal indoor operations In the rare case that any meter needs calibration adjustments the procedure for doing so should be performed by qualified technical personnel such as the Phenix Technol...

Page 10: ...4 1...

Page 11: ...5 1 ELECTRICAL DIAGRAMS Drawing Number Description 1 9907010 VMS 2 Electrical Schematic...

Page 12: ......

Page 13: ...1 Fuse 5 1603503 KTK 10 Fuse 1 1423265 Neon Lamp Green 2 N A Output lead wires 1 1356212 Multilamm Plug Black 1 1356213 Multilamm Plug Red 4 1353042 Gator Clip 20 Amp 2 1353041 Gator Clip Boot Black...

Page 14: ...g parts to include the serial number of the unit as well as the part number of the replacement part When your purchase order is received at our office a representative of Phenix Technologies will cont...

Page 15: ...for Return Cause of Defect If Phenix Technologies Inc deems return of the part appropriate it will then issue an Authorization for Return If return is not deemed advisable other inspection arrangement...

Reviews: