background image

KVM300 

 

 

13

-

1

 

SECTION 13:  CIRCUIT DIAGRAM SYMBOLS

 

 

Dispositif De Sur

Interrupteur Normalement

Interrupteur Normalement

Maintenu Ouvert

Interrupteur Normalement

Maintenu Ferme

Ouvert Momentanement

Ferme Momentanement

Interrupteur Normalement

DESCRIPTION

Condensateur

Unite d'amplificateur

Relais, Contacteur

Transformateur

Condensateur electrol

Transformateur de 

Resistance Variable

Prise de Courant

Contact Normalement 

Contact Normalement

Changement

Insrument Analogue

Diode Zener

Cable blinde

T

Transformer

Device

Current Overload 

Momentary Switch

Normally Open

Momentary Switch

Normally Closed

Normally Closed

Maintained Switch

Maintained Switch

Normally Closed

Normally Open

Normally Open

Thyristor

Zener

Diode

Analog Meter

Shielded Wire

Transistor

Changeover Contact

Relay Contact

Relay Contact

Connector

Terminal Block

DP

SW

SW

SW

SW

SCR

Z

D

TR

M

K

K

K

TB

X

Intensite

Diode

Transisteur

Thyristor

Borne

Ouvert

Ferme

Contact de 

SYMBOLE ZU SCHEMA

SYMBOLES POUR SCHEMA DE CIRCUIT

CIRCUIT DIAGRAM SYMBOLS

Variable Resisitor

Resistor

Lamp, Indicator

Neon

Movistor

Motor

Inductor

Relay, Contactor

Circuit Breaker

Current Transfomer

Fuse

Electrolytic Capacitor

Bushing

Capacitor

Surge Arrestor

Amplifier

BSHG

LP

R

R

NE

MOV

MOT

CB

K

L

CT

F

C

SYMBOL

ARSR

C

REF

A

Tranversee

Parafoudre

Moteur

Parafoudre

Lampe

Resistance

Courant

Fusible

Interupteur

Self

DESCRIPTION

Parafoudre

Transformer

Oeffnungskontakt

Abgeschirmetes Kabel

UeberstromschutzEinheit

Schrittschalter

Druckschalter

(Schliesser)

Schrittshalter

(Oeffner)

(Schliesser)

(Oeffner)

Druckschalter

Analog Meter

Transistor

Thyristor

Diode

Zener

Losbare Klemme

Steckverbindung

Schlierskontakt

Umschaltkontakt

BEMENKUNG

Ueberspannungsableiter

Ueberspannungsableiter

Eleckrolytik kondensator

Stromtransformer

Durchfuehoung

Widerstand

Movistor

Meldeleuchte

Widerstand

Motor

Sicherung

Drossel, Spule

Relais, Schutz

Unterbrecher

Kondensator

Verstarker

 

 

Summary of Contents for KVM300

Page 1: ...KVM300 AC KILOVOLTMETER MODEL NO KVM300 VERSION 2 1 Copyright Phenix Technologies Inc JPG SLU MAY 2008 REV 9 4 14 nab...

Page 2: ...ECTRICAL SET UP OPERATIONAL NOTES 4 OPERATING INSTRUCTIONS 5 CALIBRATION 6 MECHANICAL MAINTENANCE 7 STORAGE OF EQUIPMENT 8 TROUBLESHOOTING 9 RECOMMENDED SPARE PARTS 10 PARTS ORDERING INFORMATION 11 RE...

Page 3: ...KVM300 1 1 SECTION 1 DANGER WARNINGS WARNING Complete Grounding of this unit is necessary for the safe operation of this equipment Disconnect inputs before ungrounding this equipment...

Page 4: ...h Voltage Test Equipment have been listed below for your reference Become familiar with your instrument before performing an actual test Know your work area check that all circuits are de energized an...

Page 5: ...try Display is 4 Digit LED with adjustable backlighting ACCURACY 1 of Reading 3 counts from 10 100 of Range FUNCTION SELECTIONS 1 Peak 2 Peak responding calibrated to RMS Value 2 Peak Peak responding...

Page 6: ...round 6 BNC INPUT CONNECTOR This BNC input connector connects the meter module to the divider 7 BACKLIGHT DIMMER This dial adjusts the intensity of the backlight for use during low light conditions 8...

Page 7: ...inspection to determine if the unit was damaged in shipment If there are any signs of physical damage such as dents scratches or oil leaks contact the factory before proceeding NOTE Read and understa...

Page 8: ...will affect the AC calibration CAUTION The meter module has to be grounded for safe and proper operation Connect the ground post on the metering module to an appropriate ground A 10 lead is supplied...

Page 9: ...sure voltage as required Meter low range should not be used past 30kV Meter may not be accurate past 100 of reading and actual voltage may be much higher than indicated De activate high voltage source...

Page 10: ...and 1 M 200pF AC for the highest possible accuracy Readings will correspond to the type of meter used AVG will show AVG RMS will show RMS etc Use DC range for DC signals 10M input meter Select desire...

Page 11: ...TION SHOULD ONLY BE DONE BY PERSONS FAMILIAR WITH HIGH VOLTAGE TESTING AND SAFETY PROCEDURES CALIBRATION PROCEDURES Due to the complexity and the standards required to calibrate this instrument Phenix...

Page 12: ...ainst the elements in normal use It is recommended that the finish be wiped down with an ordinary household cleaner for longer life and for proper electrical operation of the unit Also inspect all fab...

Page 13: ...olonged period the following precautions are recommended The equipment should be covered and kept in a warm dry environment 95 maximum humidity 5 to 50 degrees C Prior to placing the equipment back in...

Page 14: ...g testing because of transient discharge occurrence and won t come back on by cycling the power switch Carefully remove front panel and unplug the battery pack for approximately 30 seconds then retry...

Page 15: ...r quantity of parts should be stocked as spares In such a case contact your Phenix Technologies sales representative for a recommendation Current prices may be obtained by contacting the Parts Orderin...

Page 16: ...important when ordering parts to include the serial number of the unit as well as the part number of the replacement part When your purchase order is received at our office a representative of Phenix...

Page 17: ...er Reason for Return Cause of Defect If Phenix Technologies Inc deems return of the part appropriate it will then issue an Authorization for Return If return is not deemed advisable other inspection a...

Page 18: ...D TR M K K K TB X Intensite Diode Transisteur Thyristor Borne Ouvert Ferme Contact de SYMBOLE ZU SCHEMA SYMBOLES POUR SCHEMA DE CIRCUIT CIRCUIT DIAGRAM SYMBOLS Variable Resisitor Resistor Lamp Indica...

Page 19: ...KVM300 14 1 SECTION 14 SCHEMATICS AND DRAWINGS Drawing Number Description 1 7916004 KVM300 SCHEMATIC...

Page 20: ...or s Manual are correct If there are concerns or comments as you have used this information Phenix Technologies appreciates any feedback Unit Serial Number Sect Page s Comment Please return to Phenix...

Reviews: