7
6
6.5 IR Pin Assignment
3
1
3
1
2
2
Power 5 V
IR Blaster Signal
NC
IR Signal
Power 5 V
Grounding
IR Extender
IR Blaster
6.6 RS-232 Protocols
CMSI-424L
►
◄
Remote Control Console
PIN
Assignment
PIN
Assignment
1
NC
1
NC
2
Tx
2
Rx
3
Rx
3
Tx
4
NC
4
NC
5
GND
5
GND
6
NC
6
NC
7
NC
7
NC
8
NC
8
NC
9
NC
9
NC
Baud Rate: 19200bps
Data bit: 8 bits
Parity: None
Flow Control: None
Stop Bit: 1
7
6.7 RS-232 & Telnet Commands
Command
Description
A1~A4
Switch output A to 1~4
B1~B4
Switch output B to 1~4
C1~C4
Switch output C to 1~4
D1~D4
Switch output D to 1~4
AB...1~CD...4
Switch output ABCD... to 1~4
SETIP<IP><SubNet><GW>
Setting IP. SubNet. GateWay (Static IP)
RSTIP
IP Confi guration Was Reset to Factory
Defaults <DHCP>
IPCONFIG
Display the current IP confi g
P0
POWER OFF
P1
POWER ON
I1~I4
switch all the output to 1~4
ST
Display the current matrix status and F/
W version
RS
System Reset to A1, B2, C3 & D4
EM
Setting EDID MODE. 1-STD 2-TV
?
Display all the available commands
Quit
Exit (for telnet only)
Note:
All the commands will not be executed unless followed with a
carriage return. All letters are case-insensitive.