   CAUTIONS FOR USAGE

 

 

 

First, operate the unit on a trial run basis referring to the “Start-up of unit”.  Check that the unit is 

operating properly before placing anything inside the chamber. 
 

 

As the chamber temperature is maintained at 4 

o

C ± 1 

o

C through the circulation of forced air, do not 

block inlet or outlet for air.    Make sure no unrelated items or papers enter the air inlet. 
 

 

Proper space should be provided between the items inside the unit to allow air circulation. 

 

 

Check that the door and inner door are closed tightly.    If the door is not completely closed, the door 

check lamp lights.    A bent, ruptured or twisted door gasket causes a space between the door and frame, 
and inadequate cooling efficiency. 
 

 

When the unit is first started or ambient temperature is high, the cabinet walls may become hot.  

However, this condition does not denote a malfunction as the heat is due to the hot gases which are 
piped around the unit to prevent condensation. 
 

 

A fuse is provided under the power switch.    Place the fuse after checking of the cause when the fuse 

is blown.    Make sure that the check is performed with no item in the chamber.    (except for CE model) 
 

 

Fix the shelves securely.    Make sure the shelves are inserted firmly into the shelf support. 

 

 

If an instrument requiring a power source is placed inside the cabinet, the cable can be led through the 

access port on the cabinet.  After installation, a rubber cap should be used to seal the access port.  
Failure to do this can affect the temperature uniformity inside the cabinet and lead the condensation on 
the outside of the access port. 
 

 

Always turn off the fluorescent light when it is not necessary. 

 

 

In case condensation forms on the front glass due to a high humidity environment, wipe it off with a soft 

and dry cloth. 
 

 

After the unit is placed in its final location, secure it using the leveling feet.    Adjust them so that the 

cabinet is vertical or slightly higher in the front. 
 

 

When the unit is installed, the alarm may not be operated as the built-in nickel-cadmium battery is 

completely discharged.  This condition does not denote a malfunction.  In this case, run the unit for 
about 3 hours, then push the alarm test switch to check the battery condition.  The unit must be in 
operation for about 2 days before the battery is fully recharged after it has become completely 
discharged. 
 

 

Do not clean the unit with scrubbing brushes, acid, thinner, solvents powdered soap, cleanser or hot 

water.  These agents can scratch the paint or cause it to peel.    Plastic and rubber parts can be easily 
damaged by these materials, especially solvents.  When a neutral detergent is used to clean the unit, 
rinse thoroughly with a cloth soaked in clean water. 
 

 

Never store corrosive materials such as acid or alkali unless the container is completely sealed up.  

Corrosion may lead to failure of the unit in time. 

 

Summary of Contents for MBR-107D

Page 1: ...ries Please read the operating instructions carefully before using this product and keep the operating instructions for future use See page 29 for all model numbers Operating Instructions Blood Bank R...

Page 2: ...15 OPERATION CONTROL P 16 REMOTE ALARM TERMINAL P 16 TEMPERATURE RECORDER Usage of temperature recorder P 17 Setting of temperature recorder P 17 ROUTINE MAINTENANCE Cleaning of cabinet P 19 Cleaning...

Page 3: ...d to change without notice due to the improvement of performance or functions Contact our sales representative or agent if any page of the operating instructions is lost or page order is incorrect Con...

Page 4: ...t in a hazard to personnel possibly resulting in serious injury or death CAUTION Failure to observe CAUTION signs could result in injury to personnel and damage to the unit and associated property Sym...

Page 5: ...wer supply outlet is not grounded it will be necessary to install a ground by qualified engineers Never ground the unit through a gas pipe water main telephone line or lightning rod Such grounding may...

Page 6: ...al operation may cause electric shock or fire When removing the plug from the power supply outlet grip the power supply plug not the cord Pulling the cord may result in electric shock or fire by short...

Page 7: ...turning off of power switch The stored items may be damaged due to the change of setting Be careful not to tip over the unit during movement to prevent damage or injury Prepare a safety check sheet wh...

Page 8: ...8 REFRIGERATOR COMPONENTS 1 22 21 20 19 17 16 18 15 14 13 12 2 3 4 5 6 7 8 9 10 11...

Page 9: ...echanism Magnet door seal ensures a tight seal being formed when the door is closed 9 Temperature recorder 10 Kick plate When the unit is placed close to the wall the kick plate functions as an air ou...

Page 10: ...cell battery A roll of recording paper can be used for one month Temperature from 20 o C to 6 o C is recorded in increment of 1 o C Since it is a pressure sensitive type there is no need to supply in...

Page 11: ...r is open 8 Digital thermometer This thermometer indicates temperature of air within refrigerator It is integrated with temperature regulating circuit Since in this refrigerator cooling and heating ar...

Page 12: ...e condition may cause vibration or noise WARNING Install the unit on a sturdy floor If the floor is not strong enough or the installation site is not adequate this may result in injury from the unit f...

Page 13: ...eveling feet Extend the leveling feet by rotating them counterclockwise to contact them to the floor Ensure the unit is level See Fig 1 3 Fixing the unit Two hooks are attached to the rear of the cabi...

Page 14: ...cable can be led through the access port on the cabinet After installation a rubber cap should be used to seal the access port Failure to do this can affect the temperature uniformity inside the cabin...

Page 15: ...to minimize the temperature rise NOTICE Door alarm by opening and closing the door 1 When the door is opened and remains open for less than 3 minutes and items are removed or replaced gradually the a...

Page 16: ...sure to set the alarm switch to on again Protective circuit If the temperature controller malfunctions or if the chamber temperature falls or rises the unit is designed so that the chamber temperatur...

Page 17: ...dle is higher than the upper limit or lower than the lower limit the alarm device will be activated Setting of temperature recorder As shown in the Fig 1 pull the knob on the upper part of the tempera...

Page 18: ...g paper outlet If not all of the recording paper has been fed into the used recording paper compartment send all the recording paper in the compartment first turning the gear Battery change To change...

Page 19: ...iluted detergent can damage the plastic components For the dilution refer to the instruction of the detergent After the cleaning with the diluted detergent always wipe it off with a wet cloth Then wip...

Page 20: ...e the two screws below the shade 2 The fluorescent light can be removed by gently pulling it down 3 Insert a new fluorescent light bulb after removing the old one from the socket 4 Be sure to insert t...

Page 21: ...rm test switch is pressed The nickel cadmium batteries are not completely charged If so run the unit for about 3 hours and check again If only the buzzer or only the alarm lamp functions when the alar...

Page 22: ...el by using a screw driver 3 Pull out the control panel and then remove 2 screws mounting the warning device to the panel see Fig 3 4 Detach 2 connectors from the warning device Remove 4 screws fixing...

Page 23: ...ersonnel Always remove doors to prevent accidents such as suffocation Recycle of battery The unit contains a rechargeable battery The battery is recyclable At the end of its useful life check with you...

Page 24: ...the chemical involved German Entsorgung von Altger ten und Batterien Nur f r die Europ ische Union und L nder mit Recyclingsystemen Dieses Symbol auf den Produkten der Verpackung und oder den Begleitd...

Page 25: ...r sur les piles pictogramme du bas Si ce pictogramme est combin avec un symbole chimique il r pond galement aux exigences pos es par la Directive relative au produit chimique concern Spanish Eliminaci...

Page 26: ...Neste caso estar em conformidade com o estabelecido na Diretiva referente aos produtos qu micos em causa Italian Smaltimento di vecchie apparecchiature e batterie usate Solo per Unione Europea e Nazi...

Page 27: ...l Onderstaand symbool Dit symbool kan in combinatie met een chemisch symbool gebruikt worden In dit geval volstaan de eisen die zijn vastgesteld in de richtlijnen van de desbetreffende chemische stof...

Page 28: ...r Fin and tube type Forced air circulation Refrigerant R 134a Defrosting Forced type Fully automatic Heater for chamber 20 W Temperature control Microprocessor control system Temperature alarm Nickel...

Page 29: ...er accuracy 1 o C 2 o C to 8 o C Alarm duration 9 hours for power failure Noise level 50 dB A scale Maximum pressure 1569 kPa Rated voltage alternate current 110 V 220 V 220 V 230 V 240 V 220 V Rated...

Page 30: ...Contamination of the unit Unit interior No contamination Yes No Decontaminated Yes No Contaminated Yes No Others 3 Instructions for safe repair maintenance disposal of the unit a The unit is safe to...

Page 31: ......

Page 32: ...Printed in Japan LDCL037400 0 S0418 0 1 1 1 Sakada Oizumi machi Ora gun Gunma 370 0596 Japan PHC Corporation 2018...

Reviews: