FC-1T-1F
3 / 3
10940000
Display alerts
PS
The temperature sensor cable has short circuited.
PD
The temperature sensor is damaged or the connecting wire is broken.
tS
The Temperature knob has been turned. The display will alternately flash
t S
and the ambient temperature. The control will not
accept the new setting until the switch is clicked to the set position.
OR
The voltage switch is set to 230 but the incoming power is 120 volts. Make sure the voltage switch is in the correct position.
PF
There has been a power failure. The display will flash between the temperature and
P F
. Click the switch to the right to clear the
message.
Programming
Switch position
Function
CENTER
Displays the ambient temperature
RIGHT
Allows you to view and adjust the temperature set point
Clears alarms
LEFT
Allows you to verify if the control is in heating or cooling mode
Allows you to verify if the control is displaying Fahrenheit or Celsius
Temperature set point
The FC-1T-1F controls the temperature in a room by switching fans, lamps, or heaters on or off as the temperature
drops below or exceeds the temperature set point. The set point is the desired room temperature and can be set
between 32 and 98°F (0 and 38°C).
In
cooling mode
, the control switches on the load when the temperature exceeds the set point.
In
heating mode
, the control switches on the load when the temperature drops below the set point.
To adjust the setpoint
1.
Click the switch to the right and hold.
2.
Adjust the TEMPERATURE knob to the desired setting.
You must hold the switch in the set position while turning the TEMPERATURE knob. If this is not
done correctly, the display will flash between
t S
and the temperature display, indicating the
knob has accidentally been turned. The control will not accept the new setting until the switch is
clicked to the right.
PhasonControls.com
International: 204-233-1400
Toll-free North America: 800-590-9338