17
2.2.3
DC Power Supply Input Installation
Step 1: Check the Power Supply Type and Voltage
Make sure that the mains power supply is a DC power supply, and its voltage is 0 ~ 800 Vdc.
Step 2: Find out the DC Power Input Terminals
PE, DC+ and DC-, these are the three terminals called DC Power Input Terminals. AxN Size4 Drive
’s
DC Power Input Terminals are in the Power Supply Input Port (P1) which is on the top of the drive.
Refer to the following figures for exact locations and terminal Assignment.
Step 4: Insert Wires into Corresponding Terminals
Use a 3mm hexagonal wrench to loosen the hexagonal screws on PE, DC+ and DC- Terminals which
are in the drive’s Power Supply Input Port (P1). Insert the Wires of the DC power supply
cable into
the corresponding terminals: PE to PE, DC+ to DC+, and DC- to DC-.
NOTE:
The metal part of the cord end terminal on the wire should be fully inserted into the
corresponding terminals. Leave only the insulated part outside.
Summary of Contents for AxN 70.140.4
Page 2: ......
Page 7: ...5 1 3 Overall Dimensions...
Page 15: ...13...